Head positioning in a cone beam computed tomography unit and the effect on accuracy of the three-dimensional surface mode

被引:11
|
作者
Stamatakis, Harry C. [1 ]
Steegman, Ralph [1 ]
Dusseldorp, Joost [1 ]
Ren, Yijin [2 ]
机构
[1] Univ Groningen, Univ Med Ctr Groningen, Dept Orthodont, Groningen, Netherlands
[2] Univ Groningen, Univ Med Ctr Groningen, WJ Kolff Inst Biomed Engn & Mat Sci, Dept Orthodont, Hanzepl 1, NL-9713 GZ Groningen, Netherlands
关键词
color map; superimposition; surface models; ORTHOGNATHIC SURGERY; SEGMENTATION PROCESS; RECONSTRUCTION; VALIDATION; ARTIFACTS; IMAGES; CT;
D O I
10.1111/eos.12582
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Head position during cone beam computed tomography (CBCT) examination can easily deviate from the ideal, which may affect the accuracy of the segmented three-dimensional (3D) model. The aim of this study was to determine the effect of head positioning on the accuracy of the 3D model. A human dry skull was positioned at predetermined orientations in a CBCT scanner and scanned in multiple orientations and voxel sizes. The resulting 3D surface models were superimposed over those derived from the reproducible centered positioned skull with 0 degrees inclination. Color mapping and analysis of the differences expressed by the root mean square error (RMSE) were performed. The RMSE for each orientation using the 0.3 mm voxel ranged from 0.31 to 0.87 mm for the whole maxillofacial region, from 0.44 to 0.91 mm in the maxilla, and from 0.31 to 0.72 mm in the mandible. For the 0.4 mm voxel, the RMSE ranged from 0.47 to 0.86 mm for the whole maxillofacial region, from 0.60 to 0.96 mm in the maxilla, and from 0.56 to 0.86 mm in the mandible. The maxilla showed a slightly higher deviation than the mandible in both voxel groups. It can be concluded that the head position affects the accuracy of the segmented 3D model, but the inaccuracy does not exceed clinically relevant levels.
引用
收藏
页码:72 / 80
页数:9
相关论文
共 50 条
  • [1] Registration accuracy of three-dimensional surface and cone beam computed tomography data for virtual implant planning
    Ritter, L.
    Reiz, S. D.
    Rothamel, D.
    Dreiseidler, T.
    Karapetian, V.
    Scheer, M.
    Zoeller, J. E.
    CLINICAL ORAL IMPLANTS RESEARCH, 2012, 23 (04) : 447 - 452
  • [2] Accuracy assessment of three-dimensional surface reconstructions of teeth from Cone Beam Computed Tomography scans
    Al-Rawi, B.
    Hassan, B.
    Vandenberge, B.
    Jacobs, R.
    JOURNAL OF ORAL REHABILITATION, 2010, 37 (05) : 352 - 358
  • [3] Comparison of three midsagittal planes for three-dimensional cone beam computed tomography head reorientation
    Lee, Eon-Hwa
    Yu, Hyung-Seog
    Lee, Kee-Joon
    Han, Sang-Sun
    Jung, Hwi-Dong
    Hwang, Chung-Ju
    KOREAN JOURNAL OF ORTHODONTICS, 2020, 50 (01) : 3 - 12
  • [4] Accuracy Assessment of Three-dimensional Surface Reconstructions of In vivo Teeth from Cone-beam Computed Tomography
    Sang Yan-Hui
    Hu Hong-Cheng
    Lu Song-He
    Wu Yu-Wei
    Li Wei-Ran
    Tang Zhi-Hui
    中华医学杂志英文版, 2016, 129 (12) : 1464 - 1470
  • [5] Accuracy Assessment of Three-dimensional Surface Reconstructions of In vivo Teeth from Cone-beam Computed Tomography
    Sang, Yan-Hui
    Hu, Hong-Cheng
    Lu, Song-He
    Wu, Yu-Wei
    Li, Wei-Ran
    Tang, Zhi-Hui
    CHINESE MEDICAL JOURNAL, 2016, 129 (12) : 1464 - 1470
  • [6] Three-dimensional accuracy of measurements made with software on cone-beam computed tomography images
    Lagravere, Manuel O.
    Carey, Jason
    Toogood, Roger W.
    Major, Paul W.
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2008, 134 (01) : 112 - 116
  • [7] Accuracy of three-dimensional printed models derived from cone-beam computed tomography
    Ferraro, Joshua M.
    Falter, Jacob
    Lee, Sanghee
    Watanabe, Keiichiro
    Wu, Tai-Hsien
    Kim, Do-Gyoon
    Ko, Ching-Chang
    Tanaka, Eiji
    Deguchi, Toru
    ANGLE ORTHODONTIST, 2022, 92 (06) : 722 - 727
  • [8] Three-dimensional analysis of the airway with cone-beam computed tomography
    Stratemann, Scott
    Huang, John C.
    Maki, Koutaro
    Hatcher, David
    Miller, Arthur J.
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2011, 140 (05) : 607 - 615
  • [9] Accuracy of video observation and a three-dimensional head tracking system for detecting and quantifying robot-simulated head movements in cone beam computed tomography
    Spin-Neto, Rubens
    Matzen, Louise H.
    Schropp, Lars
    Sorensen, Thomas S.
    Gotfredsen, Erik
    Wenzel, Ann
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY, 2017, 123 (06): : 721 - 728
  • [10] Three-dimensional evaluation of the posterior airway space: differences in computed tomography and cone beam computed tomography
    Ayoub, Nassim
    Eble, Philipp
    Kniha, Kristian
    Peters, Florian
    Moehlhenrich, Stephan Christian
    Goloborodko, Evgeny
    Hoelzle, Frank
    Modabber, Ali
    CLINICAL ORAL INVESTIGATIONS, 2019, 23 (02) : 603 - 609