Non-enzymatic determination of hydrogen peroxide in milk samples using Graphite oxide/Nafion/Azure A modified electrode

被引:2
|
作者
Priya, Chandrasekaran [1 ]
Anuja, Sriraman [2 ]
Devendiran, Mani [1 ]
Babu, Rajendran Suresh [1 ,3 ]
Narayanan, Sangilimuthu Sriman [1 ]
机构
[1] Univ Madras, Dept Analyt Chem, Guindy Campus, Chennai 600025, India
[2] Loyola Coll, Dept Chem, Chennai 600034, India
[3] Ctr Fed Educ Tecnol Celso Suckow Fonseca, Lab Expt & Appl Phys, BR-20271110 Rio De Janeiro, Brazil
关键词
Amperometry; Azure A; Hydrogen peroxide; modified electrode; cyclic voltammetry; CARBON-PASTE ELECTRODE; TEMPERATURE IONIC LIQUID; SELECTIVE DETERMINATION; VOLTAMMETRIC DETERMINATION; DIHYDROXYBENZENE ISOMERS; SENSING PLATFORM; NANOPARTICLES; DOPAMINE; PALLADIUM; BIOSENSOR;
D O I
10.1007/s11581-024-05470-z
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
A novel non-enzymatic electrochemical sensor was developed with high selectivity and sensitivity for detecting biologically significant hydrogen peroxide (H2O2). The sensor utilized an electrode modified with graphite oxide/Nafion/Azure A (GO/Nf/AzA) fabricated by simple chemical adsorption method. The incorporation of AzA into the GO/Nf matrix was verified through UV-Vis and FTIR spectroscopy. Electrochemical investigations via cyclic voltammetry and differential pulse voltammetry elucidated the modified electrode's properties. Optimization of experimental parameters, including pH and scan rates, enhanced its electrochemical behavior. Cyclic voltammetry analysis revealed an apparent electron transfer rate constant (Ks) of 1.14 cm/s and a charge transfer coefficient (alpha) of 0.74. Compared to the bare graphite electrode, the modified electrode exhibited significantly higher current densities in response to H2O2 with reduced overvoltage. The reduction peak currents for H2O2 demonstrated a linear correlation with concentrations ranging from 1.3 x 10-6 M to 3.6 x 10-3 M, with a detection limit of 4.3 x 10-7 M (S/N = 3). Notably, the proposed modified electrode displayed excellent sensitivity and selectivity, presenting a promising avenue for H2O2 determination. In amperometric methods, it showcased stable and rapid responses, indicating potential for application in flow system analysis. Real sample analysis involving two distinct milk samples validated the electrodes' good recovery capabilities.
引用
收藏
页码:2869 / 2880
页数:12
相关论文
共 50 条
  • [41] A non-enzymatic sensor based on the redox of ferrocene carboxylic acid on ionic liquid film-modified screen-printed graphite electrode for the analysis of hydrogen peroxide residues in milk
    Kanyong, Prosper
    Rawlinson, Sean
    Davis, James
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2016, 766 : 147 - 151
  • [42] Non-enzymatic glucose sensing platform using self assembled cobalt oxide/graphene nanocomposites immobilized graphite modified electrode
    R. Vivekananth
    R. Suresh Babu
    K. Prasanna
    Chang Woo Lee
    R. A. Kalaivani
    [J]. Journal of Materials Science: Materials in Electronics, 2018, 29 : 6763 - 6770
  • [43] Non-enzymatic glucose sensing platform using self assembled cobalt oxide/graphene nanocomposites immobilized graphite modified electrode
    Vivekananth, R.
    Babu, R. Suresh
    Prasanna, K.
    Lee, Chang Woo
    Kalaivani, R. A.
    [J]. JOURNAL OF MATERIALS SCIENCE-MATERIALS IN ELECTRONICS, 2018, 29 (08) : 6763 - 6770
  • [44] Non-enzymatic electrocatalytic detection of hydrogen peroxide using Tungsten disulphide nanosheets modified electrodes
    Haritha, V. S.
    Kumar, S. R. Sarath
    Rakhi, R. B.
    [J]. MATERIALS SCIENCE AND ENGINEERING B-ADVANCED FUNCTIONAL SOLID-STATE MATERIALS, 2022, 285
  • [45] A novel enzymatic glucose biosensor and sensitive non-enzymatic hydrogen peroxide sensor based on graphene and cobalt oxide nanoparticles composite modified glassy carbon electrode
    Karuppiah, Chelladurai
    Palanisamy, Selvakumar
    Chen, Shen-Ming
    Veeramani, Vediyappan
    Periakaruppan, Prakash
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2014, 196 : 450 - 456
  • [46] Non-enzymatic photoelectrochemical sensing of hydrogen peroxide using hierarchically structured zinc oxide hybridized with graphite-like carbon nitride
    Xinguo Xi
    Jing Li
    Hongmei Wang
    Qi Zhao
    Hongbo Li
    [J]. Microchimica Acta, 2015, 182 : 1273 - 1279
  • [47] Non-enzymatic photoelectrochemical sensing of hydrogen peroxide using hierarchically structured zinc oxide hybridized with graphite-like carbon nitride
    Xi, Xinguo
    Li, Jing
    Wang, Hongmei
    Zhao, Qi
    Li, Hongbo
    [J]. MICROCHIMICA ACTA, 2015, 182 (7-8) : 1273 - 1279
  • [48] Electrochemical determination of hydrogen peroxide using copper/porous silicon based non-enzymatic sensor
    Ensafi, Ali A.
    Abarghoui, M. Mokhtari
    Rezaei, B.
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2014, 196 : 398 - 405
  • [49] A glassy carbon electrode modified with a nanocomposite consisting of carbon nanohorns and poly(2-aminopyridine) for non-enzymatic amperometric determination of hydrogen peroxide
    Chen, Jingchao
    He, Ping
    Bai, Hongmei
    Lei, Hong
    Zhang, Guangli
    Dong, Faqin
    Ma, Yongjun
    [J]. MICROCHIMICA ACTA, 2016, 183 (12) : 3237 - 3242
  • [50] A glassy carbon electrode modified with a nanocomposite consisting of carbon nanohorns and poly(2-aminopyridine) for non-enzymatic amperometric determination of hydrogen peroxide
    Jingchao Chen
    Ping He
    Hongmei Bai
    Hong Lei
    Guangli Zhang
    Faqin Dong
    Yongjun Ma
    [J]. Microchimica Acta, 2016, 183 : 3237 - 3242