Evaluating the magnet response in deep subcutaneous implanted cardioverter defibrillator implants

被引:1
|
作者
Richman, Tuppence [1 ,4 ]
Stanton, Tony [1 ,2 ]
Fryer, Michael [1 ]
Dayananda, Naresh [1 ]
Tung, Matthew [1 ,3 ]
机构
[1] Sunshine Coast Univ Hosp, Birtinya, Australia
[2] Univ Sunshine Coast, Sippy Downs, Australia
[3] Griffith Univ, Sch Med & Dent, Sunshine Coast, Australia
[4] 6 Doherty St, Birtinya, Qld 4557, Australia
来源
关键词
implantable cardiac devices; magnet response; subcutaneous implantable cardioverter defibrillators; ELECTRONIC DEVICES; MANAGEMENT; ARRHYTHMIAS;
D O I
10.1111/pace.14609
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
IntroductionThe manufacturer of subcutaneous implantable cardioverter defibrillators (S-ICDs) acknowledges that 'deep implants' may fail to elicit a magnet response, however, does not define 'deep implant' or recommend a maximum implant depth. This study aims to systematically evaluate the effect of subcutaneous tissue depth and magnet types on evoked magnet response. MethodsSunshine Coast University Hospital's S-ICD cohort underwent magnet response evaluation; where bar and donut magnets were compared and the evoked magnet response was recorded in three separate zones, guided by a template. Ordinal regression (OR) models assessed the relationship between the evoked magnet response and tissue depth (TD), measured via post-implant X-Ray. The patient's ability to hear the magnet response audible tone was recorded. ResultsPatients (n = 39) with measurable TD (n = 30) were analyzed. The bar magnet evoked a magnet response in all zones in 53% of patients, compared with 73% of patients with the donut magnet (p = 0.18). The relationship between bar magnet response and TD showed the odds of an evoked magnet response decreased by 11% every 1 mm increase in TD (OR of 0.89, p < 0.01), whereas the donut magnet decreased by 16% per 1 mm (OR of 0.84, p < 0.01). Directly over the S-ICD was the most effective in evoking magnet response with the bar (85% of patients), and off-centre was most effective for the donut magnet (100%). BMI and Praetorian score were not significantly associated with magnet response. We found 23% of patients were unable to detect the audible tone. ConclusionWe observed a statistically significant association between TD and ability to evoke magnet response. The bar magnet was less reliable than the donut magnet for therapy inhibition in deep implants.
引用
收藏
页码:93 / 99
页数:7
相关论文
共 50 条
  • [41] Anxiety disorders with implanted cardioverter defibrillator (ICD) patients
    Benninghoven, D
    Kunzendorf, S
    Heberlein, I
    Jantschek, G
    PSYCHOTHERAPEUT, 2006, 51 (03): : 206 - 213
  • [42] Growth and the subcutaneous implantable cardioverter defibrillator in a small child
    Spentzou, Georgia
    McLean, Andrew
    McLeod, Karen
    CARDIOLOGY IN THE YOUNG, 2019, 29 (12) : 1524 - 1524
  • [43] The Subcutaneous Implantable Cardioverter-Defibrillator: A Patient Perspective
    Nesti, Martina
    Russo, Vincenzo
    Palama, Zefferino
    Panchetti, Luca
    Garibaldi, Silvia
    Startari, Umberto
    Mirizzi, Gianluca
    Piacenti, Marcello
    Rossi, Andrea
    Sciarra, Luigi
    JOURNAL OF CLINICAL MEDICINE, 2023, 12 (20)
  • [44] Subserratus implantation of the subcutaneous implantable cardioverter-defibrillator
    Smietana, Jeffrey
    Frankel, David S.
    Serletti, Joseph M.
    Arkles, Jeffrey
    Pothineni, Naga Venkata K.
    Marchlinski, Francis E.
    Schaller, Robert D.
    HEART RHYTHM, 2021, 18 (10) : 1799 - 1804
  • [45] Subcutaneous implantable cardioverter–defibrillator: Current status and perspectives
    Niehues P.
    Frommeyer G.
    Reinke F.
    Eckardt L.
    Herzschrittmachertherapie + Elektrophysiologie, 2018, 29 (4) : 349 - 354
  • [46] Development of an Entirely Subcutaneous Implantable Cardioverter-Defibrillator
    Lupo, Pier Paolo
    Pelissero, Gabriele
    Ali, Hussam
    Sanghera, Rick
    Cappato, Riccardo
    PROGRESS IN CARDIOVASCULAR DISEASES, 2012, 54 (06) : 493 - 497
  • [47] Subcutaneous implantable cardioverter defibrillator position determines success
    Amin, A.
    Gold, M. R.
    Burke, M. C.
    Knight, B. P.
    Kalbfleisch, S. J.
    Okabe, T.
    Duffy, E.
    Stahl, W. K.
    Husby, M.
    Tyler, J.
    Houmsse, M.
    Daoud, E. G.
    Hummel, J. D.
    Augostini, R. S.
    Weiss, R.
    EUROPEAN HEART JOURNAL, 2018, 39 : 621 - 621
  • [48] Subcutaneous implantable cardioverter-defibrillator: Initial experience
    Galvao, Pedro
    Cavaco, Diogo
    Adragao, Pedro
    Costa, Francisco
    Carmo, Pedro
    Morgado, Francisco
    Bernardo, Ricardo
    Nunes, Manuela
    Abecasis, Miguel
    Neves, Jose
    Mendes, Miguel
    REVISTA PORTUGUESA DE CARDIOLOGIA, 2014, 33 (09) : 511 - 517
  • [49] Technique for subcutaneous implantable cardioverter-defibrillator extraction
    Ip, James E.
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2019, 30 (05) : 789 - 791
  • [50] The subcutaneous implantable cardioverter defibrillator in daily clinical practice
    Tardu, Ozkartal
    Alexander, Breitenstein
    Ardan, Saguner M.
    Devdas, Inderbitzin T.
    Markus, Wilhelm J.
    Stefano, Benussi
    Francesco, Maisano
    Thomas, Luscher F.
    Frank, Ruschitzka
    Jan, Steffel
    SWISS MEDICAL WEEKLY, 2017, 147