High-Throughput Ultra Performance Liquid Chromatography-Tandem Mass Spectrometry Method Validation for the Estimation of Atorvastatin and Active Metabolites in Human Plasma

被引:0
|
作者
Agrawal, Nikhil [1 ]
Mittal, Amit [1 ,2 ,3 ]
机构
[1] Lovely Profess Univ, Sch Pharmaceut Sci, Dept Pharmaceut Chem, Phagwara, India
[2] Desh Bhagat Univ, Fac Pharmaceut Sci, Dept Pharmaceut Chem, Mandi Gobindgarh, India
[3] Lovely Profess Univ, Sch Pharmaceut Sci, Dept Pharmaceut Chem, Jalandhar Delhi GT Rd NH 44, Phagwara 144411, Punjab, India
关键词
atorvastatin; active metabolites; ultra high-performance liquid chromatography-liquid chromatography; mass spectrometry; bioanalytical; method validation (UPLC-MS; MS); PARA-HYDROXY ATORVASTATIN; LC-MS/MS; SIMULTANEOUS QUANTIFICATION; MS; QUANTITATION;
D O I
10.1089/adt.2022.113
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A highly selective, sensitive, rugged, and rapid ultra high-performance liquid chromatography-tandem mass spectrometry method (UPLC-MS/MS) is optimized and validated for reliable quantification of atorvastatin (ATR) and its active metabolites, 2-hydroxy atorvastatin (2-ATR) and 4-hydroxy atorvastatin (4-ATR) in human plasma using atorvastatin-D5 (ATR-D5), 2-hydroxy atorvastatin-D5 (2-ATR-D5), and 4-hydroxy atorvastatin-D5 (4-ATR-D5) as deuterium-labeled internal standards (ISTDs), respectively. Isocratic mode chromatographic separation was used with a reverse-phase C-18 Symmetry Shield (150 x 4.6 mm, 5.0 mu m) column and a mobile phase of acetonitrile:2 mM ammonium formate (pH-3.0) [65:35%v/v] at a flow rate of 0.7 mL/min. Electrospray ionization technique with positive ion mode polarity was applied to achieve the best signal intensity and stable response. Solid-phase extraction by direct elution method was applied to extract the drugs from the plasma sample. The calibration curve range was validated from a concentration range of 0.500-250 ng/mL for ATR and 2-ATR and 0.200-20 ng/mL for 4-ATR. The within-batch and between-batch precision and accuracy were found to be consistent and reproducible for all the analytes across the validation. Extraction recoveries were >80% for all analytes and ISTDs. All peaks of analytes and the respective ISTDs were eluted within 5.2 min. In this validated method, selective multivariate analytical approaches were utilized such as best fit linearity range for different strength formulations, preventive measures for in vivo and ex vivo autodegradation of metabolites, and shorter analysis time. This validated method can be useful for challenging quantification of ATR and its active metabolites for therapeutic drug monitoring and in high-throughput clinical study sample analysis.
引用
收藏
页码:110 / 125
页数:16
相关论文
共 50 条
  • [41] Rapid Determination of Tetrodotoxin in Human Plasma by Ultra Performance Liquid Chromatography-Tandem Mass Spectrometry
    Weizhu Chen
    Yiping Zhang
    Jipeng Sun
    Quanling Xie
    Zhuan Hong
    Ruizao Yi
    Chemical Research in Chinese Universities, 2018, 34 : 905 - 911
  • [42] Development of a high-throughput liquid chromatography-tandem mass spectrometry platform for the determination of intact natriuretic peptides in human plasma
    Lenzi, Alessio
    De Cristofaro, Mariano
    Biagini, Denise
    Ghimenti, Silvia
    Armenia, Silvia
    Pugliese, Nicola R.
    Masi, Stefano
    Di Francesco, Fabio
    Lomonaco, Tommaso
    TALANTA, 2024, 275
  • [43] Development and validation of a high-throughput double solid phase extraction-liquid chromatography-tandem mass spectrometry method for the determination of tetrodotoxin in human urine and plasma
    Fong, Bonnie Mei-Wah
    Tam, Sidney
    Tsui, Sik-Hon
    Leung, Kelvin Sze-Yin
    TALANTA, 2011, 83 (03) : 1030 - 1036
  • [44] Development and validation of high-throughput liquid chromatography-tandem mass spectrometric method for simultaneous quantification of Clopidogrel and its metabolite in human plasma
    Reddy S, Raghunadha
    Divi, Koteswara Rao
    Chandiran, I. Sarath
    Jayaveera, K. N.
    Naidu, Y. K.
    Reddy, M. P. Kalyan
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2010, 878 (3-4): : 502 - 508
  • [45] Liquid chromatography-tandem mass spectrometry method of loxoprofen in human plasma
    Lee, Hye Won
    Ji, Hye Young
    Sohn, Dong Hwan
    Kim, Se-Mi
    Lee, Yong Bok
    Lee, Hye Suk
    BIOMEDICAL CHROMATOGRAPHY, 2009, 23 (07) : 714 - 718
  • [46] Determination of Escitalopram in Human Plasma by High Performance Liquid Chromatography-Tandem Mass Spectrometry
    de Sousa, Carlos E. M.
    Bonifacio, Felipe N.
    Bedor, Danilo C. G.
    Silva, Thayse M.
    Ramos, Virna L. S.
    de Souza Filho, Jose H.
    Leal, Leila B.
    Oliveira, Amanda T. C.
    de Santana, Davi P.
    LATIN AMERICAN JOURNAL OF PHARMACY, 2012, 31 (02): : 310 - 314
  • [47] Determination of LBPT in human plasma by high performance liquid chromatography-tandem mass spectrometry
    Liu, Ming
    Wang, Hongyun
    Liu, Hongzhong
    Peng, Ao
    Yang, Fen
    Wang, Wenjie
    Zhu, Liya
    Huang, Haihong
    Jiang, Ji
    Hu, Pei
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2014, 965 : 238 - 243
  • [48] Validation and application of a high-performance liquid chromatography-tandem mass spectrometry assay for mosapride in human plasma
    Ramakrishna, NVS
    Vishwottam, KN
    Manoj, S
    Koteshwara, M
    Chidambara, J
    Varma, DP
    BIOMEDICAL CHROMATOGRAPHY, 2005, 19 (07) : 539 - 548
  • [49] Development and validation of a liquid chromatography-tandem mass spectrometry method for determination of ibuprofen in human plasma
    Puangpetch, Apichaya
    Limrungsikul, Anchalee
    Prommas, Santirhat
    Rukthong, Pattarawit
    Sukasem, Chonlaphat
    CLINICAL MASS SPECTROMETRY, 2020, 15 : 6 - 12
  • [50] High-throughput determination of pesticide residues in food commodities by use of ultra-performance liquid chromatography-tandem mass spectrometry
    Garrido Frenich, A.
    Martinez Vidal, J. L.
    Pastor-Montoro, E.
    Romero-Gonzalez, R.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2008, 390 (03) : 947 - 959