High-Throughput Ultra Performance Liquid Chromatography-Tandem Mass Spectrometry Method Validation for the Estimation of Atorvastatin and Active Metabolites in Human Plasma

被引:0
|
作者
Agrawal, Nikhil [1 ]
Mittal, Amit [1 ,2 ,3 ]
机构
[1] Lovely Profess Univ, Sch Pharmaceut Sci, Dept Pharmaceut Chem, Phagwara, India
[2] Desh Bhagat Univ, Fac Pharmaceut Sci, Dept Pharmaceut Chem, Mandi Gobindgarh, India
[3] Lovely Profess Univ, Sch Pharmaceut Sci, Dept Pharmaceut Chem, Jalandhar Delhi GT Rd NH 44, Phagwara 144411, Punjab, India
关键词
atorvastatin; active metabolites; ultra high-performance liquid chromatography-liquid chromatography; mass spectrometry; bioanalytical; method validation (UPLC-MS; MS); PARA-HYDROXY ATORVASTATIN; LC-MS/MS; SIMULTANEOUS QUANTIFICATION; MS; QUANTITATION;
D O I
10.1089/adt.2022.113
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A highly selective, sensitive, rugged, and rapid ultra high-performance liquid chromatography-tandem mass spectrometry method (UPLC-MS/MS) is optimized and validated for reliable quantification of atorvastatin (ATR) and its active metabolites, 2-hydroxy atorvastatin (2-ATR) and 4-hydroxy atorvastatin (4-ATR) in human plasma using atorvastatin-D5 (ATR-D5), 2-hydroxy atorvastatin-D5 (2-ATR-D5), and 4-hydroxy atorvastatin-D5 (4-ATR-D5) as deuterium-labeled internal standards (ISTDs), respectively. Isocratic mode chromatographic separation was used with a reverse-phase C-18 Symmetry Shield (150 x 4.6 mm, 5.0 mu m) column and a mobile phase of acetonitrile:2 mM ammonium formate (pH-3.0) [65:35%v/v] at a flow rate of 0.7 mL/min. Electrospray ionization technique with positive ion mode polarity was applied to achieve the best signal intensity and stable response. Solid-phase extraction by direct elution method was applied to extract the drugs from the plasma sample. The calibration curve range was validated from a concentration range of 0.500-250 ng/mL for ATR and 2-ATR and 0.200-20 ng/mL for 4-ATR. The within-batch and between-batch precision and accuracy were found to be consistent and reproducible for all the analytes across the validation. Extraction recoveries were >80% for all analytes and ISTDs. All peaks of analytes and the respective ISTDs were eluted within 5.2 min. In this validated method, selective multivariate analytical approaches were utilized such as best fit linearity range for different strength formulations, preventive measures for in vivo and ex vivo autodegradation of metabolites, and shorter analysis time. This validated method can be useful for challenging quantification of ATR and its active metabolites for therapeutic drug monitoring and in high-throughput clinical study sample analysis.
引用
收藏
页码:110 / 125
页数:16
相关论文
共 50 条
  • [21] Direct injection ultra-performance liquid chromatography-tandem mass spectrometry for the high-throughput determination of 11 illicit drugs and metabolites in wastewater
    Ren, Hang
    Yuan, Shuai
    Zheng, Jiaming
    Luo, Ruxin
    Qiang, Huosheng
    Duan, Wenjia
    Zhao, Yunli
    Xiang, Ping
    JOURNAL OF CHROMATOGRAPHY A, 2022, 1685
  • [22] Validation of a method for quantification of ketobemidone in human plasma with liquid chromatography-tandem mass spectrometry
    Lampinen, M
    Bondesson, U
    Fredriksson, E
    Hedeland, M
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2003, 789 (02): : 347 - 354
  • [23] High-throughput analysis of ramelteon, agomelatine, and melatonin in human plasma by ultra-performance liquid chromatography–tandem mass spectrometry
    Tadashi Ogawa
    Masae Iwai
    Hideki Hattori
    Kei Zaitsu
    Takeshi Kumazawa
    Akira Ishii
    Osamu Suzuki
    Hiroshi Seno
    Forensic Toxicology, 2014, 32 : 126 - 131
  • [24] Development and validation of high-throughput liquid chromatography-tandem mass spectrometric method for simultaneous quantification of loratadine and desloratadine in human plasma
    Srinubabu, G.
    Patel, Rajaram S.
    Shedbalkarar, Vinay P.
    Rao, Allam Appa
    Rao, M. Narasimha
    Bandaru, Vera Venkata Ratnam
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2007, 860 (02): : 202 - 208
  • [25] Development and validation of a high performance liquid chromatography-tandem mass spectrometry for the determination of etodolac in human plasma
    Lee, Hyun-Soo
    Kang, Il-Mo
    Lee, Heon-Woo
    Seo, Ji-Hyung
    Ryu, Ju-Hee
    Choi, Sang-Jun
    Lee, Myung-Jae
    Jeong, Seo-Young
    Cho, Young-Wuk
    Lee, Kyung-Tae
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2008, 863 (01): : 158 - 162
  • [26] Automated high-throughput assay for microsomal binding with ultra fast liquid chromatography-tandem mass spectrometry
    Lau, Yau Yi
    Doktor, Stella
    de Morais, Sonia M.
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2012, 243
  • [27] High-throughput multiclass method for antibiotic residue analysis by liquid chromatography-tandem mass spectrometry
    Chico, J.
    Rubies, A.
    Centrich, F.
    Companyo, R.
    Prat, M. D.
    Granados, M.
    JOURNAL OF CHROMATOGRAPHY A, 2008, 1213 (02) : 189 - 199
  • [28] High-throughput quantification for a drug mixture in rat plasma -: a comparison of Ultra PerformanceTM liquid chromatography/tandem mass spectrometry with high-performance liquid chromatography/tandem mass spectrometry
    Yu, K
    Little, D
    Plumb, R
    Smith, B
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2006, 20 (04) : 544 - 552
  • [29] Structure identification and elucidation of mosapride metabolites in human urine, feces and plasma by ultra performance liquid chromatography-tandem mass spectrometry method
    Sun, Xiaohong
    Zhao, Longshan
    Niu, Lili
    Qin, Feng
    Lu, Xiumei
    Xiong, Zhili
    Li, Famei
    XENOBIOTICA, 2014, 44 (08) : 734 - 742
  • [30] Measurement of clozapine and desmethylclozapine in human serum by high-throughput liquid chromatography-tandem mass spectrometry
    Garby, D. M.
    DelRosso, R.
    Cheryk, L. A.
    CLINICAL CHEMISTRY, 2008, 54 (06) : A9 - A10