Optimization of limit of detection in Taylor dispersion analysis: Application to the size determination of vaccine antigens

被引:1
|
作者
Malburet, Camille [1 ,2 ]
Martin, Michel [3 ]
Leclercq, Laurent [1 ]
Cotte, Jean-Francois [2 ]
Thiebaud, Jerome [2 ]
Biron, Jean-Philippe [1 ]
Chamieh, Joseph [1 ]
Cottet, Herve [1 ]
机构
[1] Univ Montpellier, IBMM, CNRS, ENSCM, Montpellier, France
[2] Sanofi, Analyt Sci, 1541 Ave Marcel, F-69280 Marcy Letoile, France
[3] Univ Paris Cite, Sorbonne Univ, PMMH, CNRS, F-75005 Paris, France
来源
TALANTA OPEN | 2023年 / 7卷
关键词
Taylor dispersion analysis; Proteins; Vaccines; Limit of detection; Limit of quantification; Quantitative analysis; PROTEINS; DISEASE;
D O I
10.1016/j.talo.2023.100209
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The development of a new vaccine requires the precise characterization of all the physicochemical parameters of the vaccine antigens, which are the molecules that induce the immune response. Taylor dispersion analysis (TDA) is a promising alternative technique for the determination of diffusion coefficients and hydrodynamic radii of proteins, macromolecules and nanoparticles. In this work, TDA was used to determine the hydrodynamic radius distribution and its average value of four antigens: diphtheria toxoid (DT), tetanus toxoid (TT), hepatitis B surface antigen (HBsAg) and polyribosyl-ribitol phosphate conjugated to tetanus toxoid (PRP-T). The robustness of the results obtained was investigated on bare fused silica capillary and hydroxypropylcellulose coated capillary. The impact of operational parameters on the limit of detection (LOD) and limit of quantification (LOQ) were studied from both theoretical and experimental points of view. The influence of the diameter and the length of the capillary on the LOD and LOQ were studied as well as the impact of the mobilization pressure. General guidelines for the choice of the initial operating conditions are given for the development of future TDA methods.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] New procedure for intensity and detection limit determination in spectral trace analysis: application for trace mercury by TXRF
    Bennun, L
    Greaves, ED
    Blostein, JJ
    X-RAY SPECTROMETRY, 2002, 31 (04) : 289 - 295
  • [32] Optimization of hydrolysis conditions of amino acid analysis for UHPLC-UV antigens content determination: Bexsero vaccine a case study
    Nompari, Luca
    Orlandini, Serena
    Pasquini, Benedetta
    Fontana, Letizia
    Rovini, Michele
    Masi, Flavio
    Gotti, Roberto
    Furlanetto, Sandra
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2024, 241
  • [33] Size and charge characterization of polymeric drug delivery systems by Taylor dispersion analysis and capillary electrophoresis
    Ibrahim, Amal
    Meyrueix, Remi
    Pouliquen, Gauthier
    Chan, You Ping
    Cottet, Herve
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2013, 405 (16) : 5369 - 5379
  • [34] Taylor dispersion analysis as a tool for size measurement of PAMAM dendrimers: the effect of generation, functionality and pH
    Chhabria, Vikesh
    Forbes, Robert
    Zhou, Zhengyuan
    ANALYTICAL METHODS, 2024, 17 (01) : 170 - 177
  • [35] Size and charge characterization of polymeric drug delivery systems by Taylor dispersion analysis and capillary electrophoresis
    Amal Ibrahim
    Rémi Meyrueix
    Gauthier Pouliquen
    You Ping Chan
    Hervé Cottet
    Analytical and Bioanalytical Chemistry, 2013, 405 : 5369 - 5379
  • [36] Antigen-Adjuvant Interactions in Vaccines by Taylor Dispersion Analysis: Size Characterization and Binding Parameters
    Malburet, Camille
    Leclercq, Laurent
    Cotte, Jean-Francois
    Thiebaud, Jerome
    Marco, Sergio
    Nicolai, Marie-Claire
    Cottet, Herve
    ANALYTICAL CHEMISTRY, 2021, 93 (16) : 6508 - 6515
  • [37] Comparison of single and double detection points Taylor Dispersion Analysis for monodisperse and polydisperse samples
    Chamieh, Joseph
    Cottet, Herve
    JOURNAL OF CHROMATOGRAPHY A, 2012, 1241 : 123 - 127
  • [38] Analytical mitigation of solute-capillary interactions in double detection Taylor Dispersion Analysis
    Latunde-Dada, Seyi
    Bott, Rachel
    Hampton, Karl
    Leszczyszyn, Oksana Iryna
    JOURNAL OF CHROMATOGRAPHY A, 2015, 1408 : 255 - 260
  • [39] DESIGN OF EXPERIMENTS FOR THE DETERMINATION OF THE DETECTION LIMIT IN CHEMICAL-ANALYSIS
    KUSELMAN, I
    SHENHAR, A
    ANALYTICA CHIMICA ACTA, 1995, 306 (2-3) : 301 - 305
  • [40] DETERMINATION OF DETECTION LIMIT AND GUARANTEE OF PURITY IN EMISSION SPECTRAL ANALYSIS
    MATHERNY, M
    CHEMICKE ZVESTI, 1970, 24 (02): : 121 - &