CFD simulations for layout optimal design for ground-mounted photovoltaic panel arrays

被引:8
|
作者
Sun, Jingbo [1 ,2 ,3 ]
He, Yuan [1 ,3 ]
Li, Xueying [1 ,3 ]
Lu, Zheng [1 ,3 ]
Yang, Xiaofan [1 ,3 ,4 ]
机构
[1] Beijing Normal Univ, Fac Geog Sci, State Key Lab Earth Surface Proc & Resource Ecol, Beijing 100875, Peoples R China
[2] Beijing Normal Univ, MOE Engn Res Ctr Desertificat & Blown Sand Control, Beijing 100875, Peoples R China
[3] Beijing Normal Univ, Fac Geog Sci, Sch Nat Resources, Beijing 100875, Peoples R China
[4] Beijing Normal Univ, Fac Geog Sci, Beijing 100875, Peoples R China
关键词
Ground-mounted photovoltaic panel; Airflow; Computational fluid dynamics; Wind resistance coefficient; Surface shear stress; Optimal design; WIND LOADS; NUMERICAL-SIMULATION; THERMAL PERFORMANCE; DUST POLLUTION; PV MODULES; SOLAR; SYSTEM; IMPACT; TEMPERATURE; DEPOSITION;
D O I
10.1016/j.jweia.2023.105558
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Photovoltaic (PV) power plants play an important role in regulating regional energy structures and reducing carbon emissions. The existence of PV power plants also alters the microclimate in surrounding environments, which requires an optimal design of their layout and structural parameters. PV power plants consist of arrays of ground-mounted PV panels. In this study, 3D computational fluid dynamics (CFD) simulations based on the shear-stress transport k-omega turbulence model were performed to study airflow around ground-mounted PV panel arrays. The accuracy of the CFD model was validated by comparing the simulated results with field data. Different scenarios were established by changing the wind velocity, arrangement of PV panel arrays (i.e., row and column spacing), and key structural parameters (i.e., panel inclination angle). The results showed that the highest drag coefficient (CD) and lift coefficients (CL) were found behind the first row of the arrays for straight winds (0 degrees and 180 degrees), while the minimum wind loads (lift and drag) are encountered by the middle of the array for oblique winds (45 degrees and 135 degrees). According to the wind resistance effect, the PV panel array with an inclination angle of 35 degrees, a column spacing of 0 m, and a row spacing of 3 m had the best efficiency of wind block. As the increase of ambient wind velocity, the inclination angle should be reduced to rise the resistance efficiency and avoid possible damage to PV panels. This study provides scientific reference for an optimal design and construction of PV power plants in terms of wind resistance.
引用
收藏
页数:16
相关论文
共 50 条
  • [11] The development of ground-mounted photovoltaic systems next to transport routes
    Mittelstaedt, Nora
    Manske, David
    Thraen, Daniela
    RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2025, 208
  • [12] Optimal Layout for Facade-Mounted Solar Photovoltaic Arrays in Constrained Fields
    Rehman, Naveed Ur
    JOURNAL OF SOLAR ENERGY ENGINEERING-TRANSACTIONS OF THE ASME, 2021, 143 (03):
  • [13] Optimum ground-mounted on-grid connected photovoltaic system
    Bawazir, Raimon O.
    Cetin, Numan S.
    Fadel, Waleed
    JOURNAL OF CLEANER PRODUCTION, 2024, 447
  • [14] Wind Tunnel Experiments on Ground-Mounted Photovoltaic Solar Panels
    Lopez, A.
    Parnas, E.
    Cataldo, J.
    REVISTA INGENIERIA DE CONSTRUCCION, 2019, 34 (01): : 15 - 24
  • [15] The effectiveness of the wind barrier in mitigating soiling of a ground-mounted photovoltaic panel at different angles and particle injection heights
    Raillani, Benyounes
    Chaatouf, Dounia
    Salhi, Mourad
    Bria, Abir
    Amraqui, Samir
    Mezrhab, Ahmed
    RESULTS IN ENGINEERING, 2022, 16
  • [16] A Comparative Review: Floating Photovoltaic, Agrivoltaics, and Ground-Mounted PV Systems
    Khoja, Inam-Ur-Raheem
    Saand, Abdul Sattar
    Jamali, Muhammad Ismail
    Koondhar, Mohsin Ali
    Kaloi, Ghulam Sarwar
    Albasha, Lutfi
    Aoudia, Mouloud
    Touti, Ezzeddine
    IEEE ACCESS, 2025, 13 : 45853 - 45873
  • [17] Wind Forces on Ground-Mounted Photovoltaic Solar Systems: A Comparative Study
    Aly Mousaad Aly
    Jennifer Whipple
    Applied Solar Energy (English translation of Geliotekhnika), 2021, 57 (05): : 444 - 471
  • [18] A Linear Optimization for Slope Leveling of Ground-Mounted Centralized Photovoltaic Sites
    Tao, Yanli
    Zheng, Nan
    Cheng, Yuanzhe
    Zhu, Jianfeng
    Zhong, Weibin
    Sun, Yasong
    Zhao, Jianyong
    Dong, Baoshun
    Wang, Yongming
    Ren, Jinming
    BUILDINGS, 2024, 14 (06)
  • [19] Economic evaluation of maintenance strategies for ground-mounted solar photovoltaic plants
    Peters, Lennart
    Madlener, Reinhard
    APPLIED ENERGY, 2017, 199 : 264 - 280
  • [20] Comparative Analysis of Ground-Mounted vs. Rooftop Photovoltaic Systems Optimized for Interrow Distance between Parallel Arrays
    Awan, Ahmed Bilal
    Alghassab, Mohammed
    Zubair, Muhammad
    Bhatti, Abdul Rauf
    Uzair, Muhammad
    Abbas, Ghulam
    ENERGIES, 2020, 13 (14)