High-resolution entry and exit surface dosimetry in a 1.5 T MR-linac

被引:5
|
作者
Patterson, E. [1 ]
Stokes, P. [4 ]
Cutajar, D. [1 ]
Rosenfeld, A. [1 ,2 ]
Baines, J. [4 ,5 ]
Metcalfe, P. [1 ,2 ,3 ]
Powers, M. [4 ,5 ]
机构
[1] Univ Wollongong, Ctr Med & Radiat Phys, Wollongong, NSW, Australia
[2] Univ Wollongong, Illawarra Hlth Med Res Inst, Wollongong, NSW, Australia
[3] Ingham Inst Appl Med Res, Liverpool, NSW, Australia
[4] Townsville Hosp, Townsville Canc Ctr, Hlth Serv, Townsville, Qld, Australia
[5] James Cook Univ, Coll Sci & Engn, Townsville, Qld, Australia
关键词
MR-linac; Elekta Unity; MOSFET; Skin dose; Surface dosimetry; Monte Carlo; MV RADIOTHERAPY ACCELERATOR; SKIN DOSE MEASUREMENT; IN-VIVO DOSIMETRY; MAGNETIC-FIELD; MOSKIN DETECTOR; TLD EXTRAPOLATION; SCANNER; BEAM; ORIENTATION; ENTRANCE;
D O I
10.1007/s13246-023-01251-6
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The magnetic field of a transverse MR-linac alters electron trajectories as the photon beam transits through materials, causing lower doses at flat entry surfaces and increased doses at flat beam-exiting surfaces. This study investigated the response of a MOSFET detector, known as the MOSkin (TM), for high-resolution surface and near-surface percentage depth dose measurements on an Elekta Unity. Simulations with Geant4 and the Monaco treatment planning system (TPS), and EBT-3 film measurements, were also performed for comparison. Measured MOSkin (TM) entry surface doses, relative to D-max, were (9.9 +/- 0.2)%, (10.1 +/- 0.3)%, (11.3 +/- 0.6)%, (12.9 +/- 1.0)%, and (13.4 +/- 1.0)% for 1 x 1 cm(2), 3 x 3 cm(2), 5 x 5 cm(2), 10 x 10 cm(2), and 22 x 22 cm(2) fields, respectively. For the investigated fields, the maximum percent differences of Geant4, TPS, and film doses extrapolated and interpolated to a depth suitable for skin dose assessment at the beam entry, relative to MOSkin (TM) measurements at an equivalent depth were 1.0%, 2.8%, and 14.3%, respectively, and at a WED of 199.67 mm at the beam exit, 3.2%, 3.7% and 5.7%, respectively. The largest measured increase in exit dose, due to the electron return effect, was 15.4% for the 10 x 10 cm(2) field size using the MOSkin (TM) and 17.9% for the 22 x 22 cm(2) field size, using Geant4 calculations. The results presented in the study validate the suitability of the MOSkin (TM) detector for transverse MR-linac surface dosimetry.
引用
收藏
页码:787 / 800
页数:14
相关论文
共 50 条
  • [41] Comparison of Skin Dose for Brain Cancer Patients Between a 1.5 T MR-Linac and a Conventional Linac
    Kim, A.
    McCann, C.
    Ruschin, M. E.
    Tseng, C. L.
    Sahgal, A.
    Keller, B. M.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2020, 108 (03): : E279 - E279
  • [42] Feasibility study: Polymer Gel Dosimetry On 0.35T MR-Linac System
    Marage, L.
    Boudet, J.
    Aubignac, L.
    Bessieres, I.
    Petitfils, A.
    MEDICAL PHYSICS, 2022, 49 (06) : E769 - E769
  • [43] Commissioning of a 1.5T Elekta Unity MR-linac: A single institution experience
    Snyder, Jeffrey E.
    St-Aubin, Joel
    Yaddanapudi, Sridhar
    Boczkowski, Amanda
    Dunkerley, David A. P.
    Graves, Stephen A.
    Hyer, Daniel E.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2020, 21 (07): : 160 - 172
  • [44] Evaluation of Unity 1.5 T MR-linac plan quality in patients with prostate cancer
    Tanaka, Shohei
    Kadoya, Noriyuki
    Ishizawa, Miyu
    Katsuta, Yoshiyuki
    Arai, Kazuhiro
    Takahashi, Haruna
    Xiao, Yushan
    Takahashi, Noriyoshi
    Sato, Kiyokazu
    Takeda, Ken
    Jingu, Keiichi
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2023, 24 (12):
  • [45] Optimizing MRI Readout of Fricke Gel Dosimeters On a 1.5T MR-Linac
    MacCallum, M.
    Malajovich, I.
    Serai, S.
    Salzillo, T.
    Dresner, A.
    Ibbott, G.
    Kim, L.
    MEDICAL PHYSICS, 2022, 49 (06) : E768 - E769
  • [46] The impact of a 1.5 T MR-Linac fringe field on neighbouring linear accelerators.
    Perik, T.
    Kaas, J.
    Wittkamper, F.
    RADIOTHERAPY AND ONCOLOGY, 2017, 123 : S230 - S231
  • [47] An efficient setup for weekly dose output constancy of a 1.5T MR-Linac
    Yang, B.
    Lam, W. W.
    Ho, Y. W.
    Ho, C. C.
    Hung, C.
    Cheung, K. Y.
    Yu, S. K.
    RADIOTHERAPY AND ONCOLOGY, 2020, 152 : S710 - S711
  • [48] Preliminary functional imaging study on an integrated 1.5T MR-Linac machine
    Kadbi, M.
    Ding, Y.
    Wang, J.
    Fuller, C. D.
    RADIOTHERAPY AND ONCOLOGY, 2017, 123 : S915 - S916
  • [49] Out-of-field dose and its constituent components for a 1.5 T MR-Linac
    Yang, Bin
    Tang, Ka Keung
    Huang, Chen-Yu
    Geng, Hui
    Lam, Wai Wang
    Wong, Yeung Sum
    Tse, Mei Yan
    Lau, Ka Ki
    Cheung, Kin Yin
    Yu, Siu Ki
    PHYSICS IN MEDICINE AND BIOLOGY, 2021, 66 (22):
  • [50] Automated Planning for Prostate Stereotactic Body Radiation Therapy on the 1.5 T MR-Linac
    Naccarato, Stefania
    Rigo, Michele
    Pellegrini, Roberto
    Voet, Peter
    Akhiat, Hafid
    Gurrera, Davide
    De Simone, Antonio
    Sicignano, Gianluisa
    Mazzola, Rosario
    Figlia, Vanessa
    Ricchetti, Francesco
    Nicosia, Luca
    Giaj-Levra, Niccolo
    Cuccia, Francesco
    Stavreva, Nadejda
    Pressyanov, Dobromir S.
    Stavrev, Pavel
    Alongi, Filippo
    Ruggieri, Ruggero
    ADVANCES IN RADIATION ONCOLOGY, 2022, 7 (03)