Preparation of spherical silica hydroxyl-functionalized covalent organic polymer composites for mixed-mode liquid chromatography

被引:0
|
作者
Chen, Jun [1 ,2 ]
Wang, Xiang [1 ]
Fan, Kun [1 ]
Luo, Pan [1 ]
Peng, Huanjun [1 ]
Peng, Jingdong [1 ]
机构
[1] Southwest Univ, Sch Chem & Chem Engn, Chongqing 400715, Peoples R China
[2] China West Normal Univ, Coll Chem & Chem Engn, Chem Synth & Pollut Control Key Lab Sichuan Prov, Nanchong, Peoples R China
基金
中国国家自然科学基金;
关键词
Composites; covalent organic polymers; high-performance liquid chromatography; mixed-mode; stationary phase; STATIONARY-PHASE; CONSTRUCTION; FRAMEWORKS;
D O I
10.1002/jssc.202200637
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Covalent organic polymers are an emerging class of amorphous microporous materials that have raised increasing concerns in analytical chemistry due to their unique structural and surface chemical properties. However, the application of covalent organic polymers as mixed-mode stationary phases in chromatographic separations has rarely been reported. Herein, novel spherical silica hydroxyl-functionalized covalent organic polymer composites were successfully prepared via a layer-by-layer approach. The structure and morphology of the materials were carefully characterized by elemental analysis, Fourier-transform infrared spectroscopy, scanning electron microscopy, transmission electron microscopy, X-ray diffraction, thermogravimetric analysis, Brunauer-Emmett-Teller, and contact angle measurements. Baseline separations of various alkylbenzenes, polycyclic aromatic hydrocarbons, and nucleosides and bases were achieved on the prepared stationary phase under reversed-phase/hydrophilic interaction mode. The column efficiencies of 23 853 and 36 580 plates/m were obtained for butylbenzene and uracil, respectively, and the relative standard deviation of the retention time for continuous injections was less than 1.38% (n = 10), suggesting satisfactory column efficiency and repeatability. Additionally, this novel stationary phase realized the complete separation of the endocrine-disrupting chemicals in river water. This work affords a new route for synthesizing covalent organic polymers-based mixed-mode stationary phase and further reveals their great potential in chromatographic separation.
引用
收藏
页数:12
相关论文
共 50 条
  • [31] Facile fabrication of silica@covalent organic polymers core-shell composites as the mixed-mode stationary phase for hydrophilic interaction/reversed-phase/ion-exchange chromatography
    Chen, Jun
    Peng, Huanjun
    Zhang, Zilong
    Zhang, Zhongying
    Ni, Ranxi
    Chen, Yaping
    Chen, Piao
    Peng, Jingdong
    TALANTA, 2021, 233
  • [32] Preparation of Polymer-Based Amino Acid Stationary Phase and Its Application for Mixed-Mode Chromatography
    Hanlin Zeng
    Jingdong Peng
    Huanjun Peng
    Xiang Wang
    Zilong Zhang
    Hanqi Yang
    Jiayu Yu
    Jiajia Wu
    Chromatographia, 2024, 87 : 147 - 157
  • [33] A novel approach for the preparation of core-shell MOF/polymer composites as mixed-mode stationary phase
    Si, Tiantian
    Wang, Licheng
    Zhang, Haixia
    Liang, Xiaojing
    Lu, Xiaofeng
    Wang, Shuai
    Guo, Yong
    TALANTA, 2021, 232
  • [34] Preparation of an aminophenylboronic acid and N-isopropyl acrylamide copolymer functionalized stationary phase for mixed-mode chromatography
    Zhou, Di
    Luo, Qiurong
    Zeng, Qin
    Zheng, Yunchao
    Ren, Xiujun
    Gao, Die
    Fu, Qifeng
    Zhang, Kailian
    Xia, Zhining
    Wang, Lujun
    JOURNAL OF CHROMATOGRAPHY A, 2020, 1627 (1627)
  • [35] Preparation and characterization of glucose-based covalent organic polymer coated silica as stationary phase for high-performance liquid chromatography
    Gao, Li
    Wang, Yuan
    Qin, Yaqiong
    Sun, Yaming
    He, Lijun
    Zhang, Shusheng
    Zhao, Wenjie
    JOURNAL OF CHROMATOGRAPHY A, 2023, 1693
  • [36] Preparation and evaluation a mixed-mode stationary phase with imidazolium and carboxyl group for high performance liquid chromatography
    Xian, Hong
    Peng, Huanjun
    Wang, Xiang
    Long, Dengying
    Ni, Ranxi
    Chen, Jun
    Li, Shiyu
    Zhang, Zhongying
    Peng, Jingdong
    MICROCHEMICAL JOURNAL, 2019, 150
  • [37] Facile Fabrication of Polymeric Ionic Liquid Grafted Porous Polymer Monolith for Mixed-Mode High Performance Liquid Chromatography
    Li, Yaping
    Qi, Li
    Shen, Ying
    Zhang, Haizhi
    Ma, Huimin
    CHINESE JOURNAL OF CHEMISTRY, 2014, 32 (07) : 619 - 625
  • [38] Preparation of two zwitterionic polymer functionalized stationary phases and comparative evaluation under mixed-mode of reversed phase/hydrophilic interaction/ion exchange chromatography
    Wang, Xiang
    Zhu, Tianrun
    Wang, Xingrui
    Peng, Huanjun
    Zhou, Guangming
    Peng, Jingdong
    JOURNAL OF CHROMATOGRAPHY A, 2024, 1714
  • [39] Synthesis of monodisperse silica microspheres and modification with diazoresin for mixed-mode ultra high performance liquid chromatography separations
    Cong, Hailin
    Yu, Bing
    Tian, Chao
    Zhang, Shuai
    Yuan, Hua
    JOURNAL OF SEPARATION SCIENCE, 2017, 40 (22) : 4320 - 4328
  • [40] One-pot preparation of mercaptotetrazole-silica hybrid monoliths by the thiol-ene click reaction for mixed-mode capillary liquid chromatography
    Wang, Haojiang
    Hu, Wenli
    Zheng, Qiong
    Bian, Wei
    Lin, Zian
    JOURNAL OF SEPARATION SCIENCE, 2017, 40 (11) : 2344 - 2354