Formation of spread-out Bragg peak for helium-ion beam using microdosimetric kinetic model

被引:2
|
作者
Akagi, Takashi [1 ]
Maeda, Takuya [2 ]
Suga, Masaki [1 ]
Yamashita, Tomohiro [3 ]
机构
[1] Hyogo Ion Beam Med Ctr, Dept Radiat Phys, Tatsuno City, Hyogo, Japan
[2] Hyogo Ion Beam Med Ctr, Res Div, Tatsuno City, Japan
[3] Kobe Proton Ctr, Kobe, Japan
关键词
Helium -ion therapy; Microdosimetric kinetic model; Ridge filter; HSG cell line; CELL-SURVIVAL; THERAPY; PARTICLE; PROTON; RADIOTHERAPY; C-12; HE-4;
D O I
10.1016/j.ejmp.2023.102587
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To evaluate the applicability of microdosimetric kinetic model (MKM) to helium-ion therapy by forming a spread-out Bragg peak (SOBP) of a helium-ion beam using the MKM developed for carbon-ion radiotherapy and confirming the predictions in biological experiments. Methods: Using a ridge filter, a 90-mm wide SOBP for a 210 MeV/u helium-ion beam was created in a broad beam delivery system. The ridge filter was designed such that a uniform biological response was achieved with a cell survival rate of 7% over the SOBP region. Biological experiments were then performed using the SOBP beam in a human salivary gland (HSG) cell line to measure the cell survival rates. Results: The biological responses were uniform in the SOBP region, as expected by the MKM; however, the mean of the measured cell survival rates was (11.2 +/- 0.6) % in the SOBP region, which was 60% higher than the designed rate. When investigating the biological parameters of the HSG cell line used in the experiments, we found that they were altered slightly from the MKM parameters used for carbon-ion radiotherapy. The new beta parameter reproduced the measured survival rates within 6.5% in the SOBP region. Conclusion: We produced biologically uniform SOBP using MKM for carbon-ion radiotherapy. The measured survival rates in the SOBP region were higher than expected, and the survival rates were reproduced by modifying the MKM parameter. This study was limited to one SOBP, and further investigations are required to prove that MKM is generally applicable to helium-ion radiotherapy.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] The prediction of output factors for spread-out proton Bragg peak fields in clinical practice
    Kooy, HM
    Rosenthal, SJ
    Engelsman, M
    Mazal, A
    Slopsema, RL
    Paganetti, H
    Flanz, JB
    PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (24): : 5847 - 5856
  • [42] Reconstruction of the 3-dimensional spread-out Bragg peak with the MINUIT fit package
    Inkyu Park
    Seokon Kang
    Sangnam Park
    Geun-Beom Kim
    Garam Hahn
    Journal of the Korean Physical Society, 2012, 60 : 1327 - 1332
  • [43] Reconstruction of the 3-Dimensional Spread-out Bragg Peak with the MINUIT Fit Package
    Park, Inkyu
    Kang, Seokon
    Park, Sangnam
    Kim, Geun-Beom
    Hahn, Garam
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2012, 60 (09) : 1327 - 1332
  • [44] Spread-out Bragg peak measurements using a compact quality assurance range calorimeter at the Clatterbridge cancer centre
    Shaikh, Saad
    Escribano-Rodriguez, Sonia
    Radogna, Raffaella
    Kelleter, Laurent
    Godden, Connor
    Warren, Matthew
    Attree, Derek
    Saakyan, Ruben
    Mortimer, Linda
    Corlett, Peter
    Warry, Alison
    Gosling, Andrew
    Baker, Colin
    Poynter, Andrew
    Kacperek, Andrzej
    Jolly, Simon
    PHYSICS IN MEDICINE AND BIOLOGY, 2024, 69 (11):
  • [45] Investigating the Implications of a Variable RBE on Proton Dose Fractionation Across a Clinical Pencil Beam Scanned Spread-Out Bragg Peak
    Marshall, Thomas I.
    Chaudhary, Pankaj
    Michaelidesova, Anna
    Vachelova, Jana
    Davidkova, Marie
    Vondracek, Vladimir
    Schettino, Giuseppe
    Prise, Kevin M.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2016, 95 (01): : 70 - 77
  • [46] Feasibility Study of Quality Assurance of Proton Range Compensator Using the Proximal Side of Spread-Out Bragg Peak
    Jin, H.
    Ahmad, S.
    MEDICAL PHYSICS, 2017, 44 (06)
  • [47] Demonstration of the FLASH Effect Within the Spread-out Bragg Peak After Abdominal Irradiation of Mice
    Evans, Tucker
    Cooley, James
    Wagner, Miles
    Yu, Tianning
    Zwart, Townsend
    INTERNATIONAL JOURNAL OF PARTICLE THERAPY, 2022, 8 (04) : 68 - 75
  • [48] Response of a radioresistant human melanoma cell line along the proton spread-out Bragg peak
    Petrovic, Ivan
    Ristic-Fira, Aleksandra
    Todorovic, Danijela
    Koricanac, Lela
    Valastro, Lucia
    Cirrone, Pablo
    Cuttone, Giacomo
    INTERNATIONAL JOURNAL OF RADIATION BIOLOGY, 2010, 86 (09) : 742 - 751
  • [49] Simulation of the Interaction of Protons with Devices for Forming a Spread-Out Bragg Peak by the Monte Carlo Method
    A. A. Abduvaliev
    J. Kh. Khushvaktov
    T. N. Tran
    Physics of Particles and Nuclei Letters, 2023, 20 : 1287 - 1291
  • [50] Evaluation of the effect of soft tissue composition on the characteristics of spread-out Bragg peak in proton therapy
    Ghorbani, Mahdi
    Jia, Sayyed Bijan
    Khosroabadi, Mohsen
    Sadoughi, Hamid Reza
    Knaup, Courtney
    JOURNAL OF CANCER RESEARCH AND THERAPEUTICS, 2017, 13 (06) : 974 - 980