Formation of spread-out Bragg peak for helium-ion beam using microdosimetric kinetic model

被引:2
|
作者
Akagi, Takashi [1 ]
Maeda, Takuya [2 ]
Suga, Masaki [1 ]
Yamashita, Tomohiro [3 ]
机构
[1] Hyogo Ion Beam Med Ctr, Dept Radiat Phys, Tatsuno City, Hyogo, Japan
[2] Hyogo Ion Beam Med Ctr, Res Div, Tatsuno City, Japan
[3] Kobe Proton Ctr, Kobe, Japan
关键词
Helium -ion therapy; Microdosimetric kinetic model; Ridge filter; HSG cell line; CELL-SURVIVAL; THERAPY; PARTICLE; PROTON; RADIOTHERAPY; C-12; HE-4;
D O I
10.1016/j.ejmp.2023.102587
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To evaluate the applicability of microdosimetric kinetic model (MKM) to helium-ion therapy by forming a spread-out Bragg peak (SOBP) of a helium-ion beam using the MKM developed for carbon-ion radiotherapy and confirming the predictions in biological experiments. Methods: Using a ridge filter, a 90-mm wide SOBP for a 210 MeV/u helium-ion beam was created in a broad beam delivery system. The ridge filter was designed such that a uniform biological response was achieved with a cell survival rate of 7% over the SOBP region. Biological experiments were then performed using the SOBP beam in a human salivary gland (HSG) cell line to measure the cell survival rates. Results: The biological responses were uniform in the SOBP region, as expected by the MKM; however, the mean of the measured cell survival rates was (11.2 +/- 0.6) % in the SOBP region, which was 60% higher than the designed rate. When investigating the biological parameters of the HSG cell line used in the experiments, we found that they were altered slightly from the MKM parameters used for carbon-ion radiotherapy. The new beta parameter reproduced the measured survival rates within 6.5% in the SOBP region. Conclusion: We produced biologically uniform SOBP using MKM for carbon-ion radiotherapy. The measured survival rates in the SOBP region were higher than expected, and the survival rates were reproduced by modifying the MKM parameter. This study was limited to one SOBP, and further investigations are required to prove that MKM is generally applicable to helium-ion radiotherapy.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Relative biological effectiveness in a proton spread-out Bragg peak formed by pencil beam scanning mode
    Michaelidesova, Anna
    Vachelova, Jana
    Puchalska, Monika
    Brabcova, Katerina Pachnerova
    Vondracek, Vladimir
    Sihver, Lembit
    Davidkova, Marie
    AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2017, 40 (02) : 359 - 368
  • [22] Plasmid DNA damage by heavy ions at spread-out Bragg peak energies
    H. M. Dang
    M. J. van Goethem
    E. R. van der Graaf
    S. Brandenburg
    R. Hoekstra
    T. Schlathölter
    The European Physical Journal D, 2010, 60 : 51 - 58
  • [23] Optimization of current modulation function for proton spread-out Bragg peak fields
    Lu, HM
    Kooy, H
    MEDICAL PHYSICS, 2006, 33 (05) : 1281 - 1287
  • [24] Measurement of microdosimetric spectra produced from a 290 MeV/n Spread Out Bragg Peak carbon beam
    Endo, Satoru
    Takada, Masashi
    Tanaka, Hiroki
    Onizuka, Yoshihiko
    Tanaka, Kenichi
    Miyahara, Nobuyuki
    Baba, Hiromi
    Oishi, Ayumu
    Ishikawa, Masayori
    Hoshi, Masaharu
    Kimura, Shinzo
    Minematsu, Masakazu
    Morimune, Yuki
    Kojima, Yasuaki
    Shizuma, Kiyoshi
    RADIATION AND ENVIRONMENTAL BIOPHYSICS, 2010, 49 (03) : 469 - 475
  • [25] Plasmid DNA damage by heavy ions at spread-out Bragg peak energies
    Dang, H. M.
    van Goethem, M. J.
    van der Graaf, E. R.
    Brandenburg, S.
    Hoekstra, R.
    Schlatholter, T.
    EUROPEAN PHYSICAL JOURNAL D, 2010, 60 (01): : 51 - 58
  • [26] Cell survival probability in a spread-out Bragg peak for novel treatment planning
    Surdutovich, Eugene
    Solov'yov, Andrey V.
    EUROPEAN PHYSICAL JOURNAL D, 2017, 71 (08):
  • [27] Measurement of microdosimetric spectra produced from a 290 MeV/n Spread Out Bragg Peak carbon beam
    Satoru Endo
    Masashi Takada
    Hiroki Tanaka
    Yoshihiko Onizuka
    Kenichi Tanaka
    Nobuyuki Miyahara
    Hiromi Baba
    Ayumu Oishi
    Masayori Ishikawa
    Masaharu Hoshi
    Shinzo Kimura
    Masakazu Minematsu
    Yuki Morimune
    Yasuaki Kojima
    Kiyoshi Shizuma
    Radiation and Environmental Biophysics, 2010, 49 : 469 - 475
  • [28] Correcting Spread-Out Bragg Peak Slope Using Time-Resolved Monte Carlo Simulations and Beam Current Modulation
    Hill, P.
    Klein, E.
    Bloch, C.
    MEDICAL PHYSICS, 2012, 39 (06) : 3871 - 3872
  • [29] Calculation method using Clarkson integration for the physical dose at the center of the spread-out Bragg peak in carbon-ion radiotherapy
    Tajiri, Minoru
    Maeda, Takamasa
    Koba, Yusuke
    Isobe, Yoshiharu
    Kuroiwa, Toshitaka
    Fukuda, Shigekazu
    Tanimoto, Katsuyuki
    Shibayama, Koichi
    MEDICAL PHYSICS, 2013, 40 (07)
  • [30] Improving the Accuracy of Monte Carlo Spread-Out Bragg Peak Treatment Head Models Using Beam Current Modulation Optimization
    Bednarz, B.
    Lu, H.
    Engelsman, M.
    Paganetti, H.
    MEDICAL PHYSICS, 2010, 37 (06)