Monitoring and Prediction of Indoor Air Quality for Enhanced Occupational Health

被引:3
|
作者
Pop , Adela [1 ]
Fanca, Alexandra [1 ]
Gota, Dan Ioan [1 ]
Valean, Honoriu [1 ]
机构
[1] Tech Univ Cluj Napoca, Cluj Napoca, Romania
来源
关键词
Machine learning; indoor air quality; humidity; carbon dioxide; relative humidity; SYSTEM;
D O I
10.32604/iasc.2023.025069
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
The amount of moisture in the air is represented by relative humidity (RH); an ideal level of humidity in the interior environment is between 40% and 60% at temperatures between 18 degrees and 20 degrees Celsius. When the RH falls below this level, the environment becomes dry, which can cause skin dryness, irritation, and discomfort at low temperatures. When the humidity level rises above 60%, a wet atmosphere develops, which encourages the growth of mold and mites. Asthma and allergy symptoms may occur as a result. Human health is harmed by excessive humidity or a lack thereof. Dehumidifiers can be used to provide an optimal level of humidity and a stable and pleasant atmosphere; certain models disinfect and purify the water, reducing the spread of bacteria. The design and implementation of a client-server indoor and outdoor air quality monitoring application are presented in this paper. The Netatmo station was used to acquire the data needed in the application. The client is an Android application that allows the user to monitor air quality over a period of their choosing. For a good monitoring process, the Netatmo modules were used to collect data from both environments (indoor: temperature (T), RH, carbon dioxide (CO2), atmospheric pressure (Pa), noise and outdoor: T and RH). The data is stored in a database, using MySQL. The Android application allows the user to view the evolution of the measured parameters in the form of graphs. Also, the paper presents a prediction model of RH using Azure Machine Learning Studio (Azure ML Studio). The model is evaluated using metrics: Mean Absolute Error (MAE), Root Mean Squared Error (RMSE), Relative Absolute Error (RAE), Relative Squared Error (RSE) and Coefficient of Determination (CoD).
引用
收藏
页码:925 / 940
页数:16
相关论文
共 50 条
  • [31] Indoor air humidity, air quality, and health - An overview
    Wolkoff, Peder
    INTERNATIONAL JOURNAL OF HYGIENE AND ENVIRONMENTAL HEALTH, 2018, 221 (03) : 376 - 390
  • [32] Prediction of Concentration Change and Influence Analysis of Indoor/Outdoor in Subway Station using Indoor Air Quality Monitoring Data
    Kim, Jong Bum
    Park, Sechan
    Lee, Yongil
    Lee, Seonyeop
    Kim, Jeongho
    Park, Duckshin
    JOURNAL OF KOREAN SOCIETY FOR ATMOSPHERIC ENVIRONMENT, 2022, 38 (01) : 30 - 45
  • [33] An Intelligent Wireless Sensing and Control System to Improve Indoor Air Quality: Monitoring, Prediction, and Preaction
    Yu, Tsang-Chu
    Lin, Chung-Chih
    INTERNATIONAL JOURNAL OF DISTRIBUTED SENSOR NETWORKS, 2015,
  • [34] Indoor air quality: an environmental and health priority
    La Grutta, Stefania
    Cibella, Fabio
    EPIDEMIOLOGIA & PREVENZIONE, 2009, 33 (03): : 115 - 118
  • [35] HOUSING AND HEALTH - INDOOR AIR-QUALITY
    LOWRY, S
    BRITISH MEDICAL JOURNAL, 1989, 299 (6712): : 1388 - 1390
  • [36] Comment on 'Indoor air quality and health' - Discussion
    Yu, KN
    ATMOSPHERIC ENVIRONMENT, 2000, 34 (16) : 2663 - 2663
  • [37] Indoor air quality and respiratory health of children
    Franklin, Peter J.
    PAEDIATRIC RESPIRATORY REVIEWS, 2007, 8 (04) : 281 - 286
  • [38] Assessment of Indoor Air Quality Problems in Office-Like Environments: Role of Occupational Health Services
    Carrer, Paolo
    Wolkoff, Peder
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2018, 15 (04):
  • [39] Use of an Electronic Nose for Indoor Air Quality Monitoring
    Sironi, Selena
    Eusebio, Lidia
    Capelli, Laura
    Remondini, Marco
    Del Rosso, Renato
    NOSE2014: 4TH INTERNATIONAL CONFERENCE ON ENVIRONMENTAL ODOUR MONITORING AND CONTROL, 2014, 40 : 73 - +
  • [40] Chamber Studies for Indoor Air Quality Modeling and Monitoring
    Chinthala, Sumanth
    Gulia, Sunil
    Khare, Mukesh
    INDOOR ENVIRONMENTAL QUALITY, ACIEQ, 2020, 60 : 45 - 52