Removal of harmful oxyanions from contaminated water by Donnan dialysis

被引:3
|
作者
Akula, Vishnu V. [1 ]
Philip, Ligy [1 ]
机构
[1] IIT Madras, Dept Civil Engn, Environm Engn Div, Chennai 600036, India
关键词
Oxyanion; Donnan dialysis; Anion exchange membranes; FAD PET 75; FAS PET 75; Predictive kinetic modelling; NITRATE REMOVAL; ANION-EXCHANGE; WASTE-WATER; PERCHLORATE; REGENERATION; GROUNDWATER; REDUCTION; MEMBRANES; RESIN;
D O I
10.1016/j.jwpe.2023.104085
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The removal of oxyanions like nitrate, sulphate, phosphate, chromate and perchlorate was investigated in single, binary and multi-component feed systems using Donnan dialysis across two homogeneous anion exchange membranes, FAD PET 75 and FAS PET 75. The ion exchange isotherms were established for oxyanion - chloride binary systems with both anion exchange membranes. The effect of initial concentration, recirculation flow rate, and receiver salt concentration was examined with FAD PET 75. The overall kinetic coefficient was calculated from the flux equation and was used to compare the transport kinetics of different oxyanions. The kinetics of oxyanions removal followed the order of nitrate > perchlorate > chromate > sulphate > phosphate, which can be attributed to the hydrated radius and structure of the oxyanions. The presence of co-existing oxyanions did not show a significant effect on the removal of nitrate, perchlorate, and chromate while sulphate and phosphate were influenced by their presence. Based on the present study, FAD PET 75 was able to remove all the target oxyanions effectively whereas FAS PET 75 was ineffective in the removal of sulphate and phosphate because of the higher cross linkage of the matrix which was evident with its lower water content.
引用
收藏
页数:12
相关论文
共 50 条
  • [31] Potential of Donnan dialysis water purification processes
    Hasson, David
    Semiat, Raphael
    Shemer, Hilla
    DESALINATION AND WATER TREATMENT, 2017, 69 : 12 - 17
  • [32] Elimination of selected anions and cations from water by means of the donnan dialysis
    Wiśniewski J.A.
    Kabsch-Korbutowicz M.
    Environment Protection Engineering, 2021, 43 (03): : 189 - 205
  • [33] ELIMINATION OF SELECTED ANIONS AND CATIONS FROM WATER BY MEANS OF THE DONNAN DIALYSIS
    Wisniewski, Jacek A.
    Kabsch-Korbutowicz, Malgorzata
    ENVIRONMENT PROTECTION ENGINEERING, 2017, 43 (03): : 189 - 205
  • [34] Divalent Cation Removal by Donnan Dialysis for Improved Reverse Electrodialysis
    Rijnaarts, Timon
    Shenkute, Nathnael T.
    Wood, Jeffery A.
    de Vos, Wiebe M.
    Nijmeijer, Kitty
    ACS SUSTAINABLE CHEMISTRY & ENGINEERING, 2018, 6 (05): : 7035 - 7041
  • [35] Phosphate removal from aqueous solution by Donnan dialysis with anion-exchange membrane
    Shi-yang Chen
    Zhou Shi
    Yong Song
    Xue-rui Li
    Yuan-lai Hu
    Journal of Central South University, 2014, 21 : 1968 - 1973
  • [36] Phosphate removal from aqueous solution by Donnan dialysis with anion-exchange membrane
    陈世洋
    施周
    宋勇
    李学瑞
    胡远来
    JournalofCentralSouthUniversity, 2014, 21 (05) : 1968 - 1973
  • [37] Fluoride removal from diluted solutions by Donnan dialysis using full factorial design
    Ali Boubakri
    Nawel Helali
    Mohamed Tlili
    Mohamed Ben Amor
    Korean Journal of Chemical Engineering, 2014, 31 : 461 - 466
  • [38] Phosphate removal from aqueous solution by Donnan dialysis with anion-exchange membrane
    Chen Shi-yang
    Shi Zhou
    Song Yong
    Li Xue-rui
    Hu Yuan-lai
    JOURNAL OF CENTRAL SOUTH UNIVERSITY, 2014, 21 (05) : 1968 - 1973
  • [39] Fluoride removal from diluted solutions by Donnan dialysis using full factorial design
    Boubakri, Ali
    Helali, Nawel
    Tlili, Mohamed
    Ben Amor, Mohamed
    KOREAN JOURNAL OF CHEMICAL ENGINEERING, 2014, 31 (03) : 461 - 466
  • [40] Fluoride removal from diluted solutions by Donnan dialysis with anion-exchange membranes
    Hichour, M
    Persin, F
    Molénat, J
    Sandeaux, J
    Gavach, C
    DESALINATION, 1999, 122 (01) : 53 - 62