Fluoride removal from diluted solutions by Donnan dialysis using full factorial design

被引:47
|
作者
Boubakri, Ali [1 ]
Helali, Nawel [2 ]
Tlili, Mohamed [2 ]
Ben Amor, Mohamed [2 ]
机构
[1] Ctr Res & Water Technol, Lab Wastewater Treatment, Soliman 8020, Tunisia
[2] Ctr Res & Water Technol, Lab Nat Water Treatment, Soliman 8020, Tunisia
关键词
Fluoride Removal; Fluoride Flux; Donnan Dialysis; Anion Exchange Membrane; Factorial Design; AQUEOUS-SOLUTION; EXCHANGE; GROUNDWATER; WATER;
D O I
10.1007/s11814-013-0263-9
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Excessive fluoride concentration in potable water can lead to fluorosis of teeth and bones. In the present study, Donnan dialysis (DD) is applied for the removal of fluoride ions from diluted sodium fluoride solutions. A four factor two level (2(4)) full factorial design was used to investigate the influence of different physico-chemical parameters on fluoride removal efficiency (Y (F) ) and fluoride flux (J (F) ) through anion exchange membrane. The statistical design determines factors which have the important effects on Donnan dialysis performance and studies all interactions among the considered parameters. The four significant factors were initial fluoride concentration, feed flow rate, temperature and agitation speed. The experimental results and statistical analysis show that the temperature and agitation speed have positive effects on fluoride removal efficiency and the initial fluoride concentration has a negative effect. In the case of fluoride flux, feed flow rate and initial concentration are the main effect and all factors have a positive effect. The interaction between studied parameters was not negligible on two responses. A maximum fluoride removal of 75.52% was obtained under optimum conditions and the highest value of fluoride flux obtained was 2.4 mg/cm(2)center dot h. Empirical regression models were also obtained and used to predict the flux and the fluoride removal profiles with satisfactory results.
引用
收藏
页码:461 / 466
页数:6
相关论文
共 50 条
  • [1] Fluoride removal from diluted solutions by Donnan dialysis using full factorial design
    Ali Boubakri
    Nawel Helali
    Mohamed Tlili
    Mohamed Ben Amor
    Korean Journal of Chemical Engineering, 2014, 31 : 461 - 466
  • [2] Fluoride removal from diluted solutions by Donnan dialysis with anion-exchange membranes
    Hichour, M
    Persin, F
    Molénat, J
    Sandeaux, J
    Gavach, C
    DESALINATION, 1999, 122 (01) : 53 - 62
  • [3] Fluoride removal from waters by Donnan dialysis
    Hichour, M
    Persin, F
    Sandeaux, J
    Gavach, C
    SEPARATION AND PURIFICATION TECHNOLOGY, 2000, 18 (01) : 1 - 11
  • [4] Fluoride removal from waters by Donnan dialysis
    Lab. Mat. et Procedes Membranaires, UMR 5635, CNRS, 1919 Rte. M., Montpellier, France
    Sep. Purif. Technol., 1 (1-11):
  • [5] Modelisation of fluoride removal in Donnan dialysis
    Ruiz, T
    Persin, F
    Hichour, M
    Sandeaux, J
    JOURNAL OF MEMBRANE SCIENCE, 2003, 212 (1-2) : 113 - 121
  • [6] Boron removal from aqueous solutions by adsorption using full factorial design
    Öztürk, N
    Kavak, D
    FRESENIUS ENVIRONMENTAL BULLETIN, 2003, 12 (12): : 1450 - 1456
  • [7] Fluoride removal by Donnan dialysis with anion exchange membranes
    Durmaz, F
    Kara, H
    Cengeloglu, Y
    Ersoz, M
    DESALINATION, 2005, 177 (1-3) : 51 - 57
  • [8] Bromide Ion Removal from Water Solutions by Donnan Dialysis
    Lakomska, Sylwia
    Wisniewski, Jacek A.
    OCHRONA SRODOWISKA, 2012, 34 (01): : 33 - 39
  • [9] Application of Donnan Dialysis for Cyanide Removal from Aqueous Solutions
    Nasser, Iben I.
    Ahmed, C.
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH, 2015, 9 (02) : 505 - 510
  • [10] SIMULTANEOUS REMOVAL OF NITRATES AND NITRITES FROM WATER BY DONNAN DIALYSIS USING DOEHLERT DESIGN
    Trifi, IKhlass Marzouk
    Trifi, Beyram
    Djemal, Amira
    Hamrouni, Bechir
    ENVIRONMENTAL ENGINEERING AND MANAGEMENT JOURNAL, 2021, 20 (06): : 973 - 983