Rapid and Simultaneous Determination of 238Pu, 239Pu, 240Pu, and 241Pu in Samples with High-Level Uranium Using ICP-MS/MS and Extraction Chromatography

被引:6
|
作者
Huang, Zhao [1 ,3 ]
Hou, Xiaolin [1 ,2 ,5 ]
Zhao, Xue [1 ,2 ,4 ]
机构
[1] Chinese Acad Sci, Inst Earth Environm, Xian AMS Ctr, Shaanxi Key Lab Accelerator Mass Spectrometry,Stat, Xian 710061, Peoples R China
[2] Pilot Natl Lab Marine Sci & Technol Qingdao, Open Studio Ocean Continental Climate & Environm C, Qingdao 266061, Peoples R China
[3] Univ Chinese Acad Sci, Beijing 100049, Peoples R China
[4] Xian Inst Innovat Earth Environm Res, Xian 710061, Peoples R China
[5] Tech Univ Denmark, Dept Environm & Resource Engn, DK-4000 Roskilde, Denmark
基金
中国国家自然科学基金;
关键词
PLASMA-MASS SPECTROMETRY; PLUTONIUM ISOTOPES; PU ISOTOPES; ENVIRONMENTAL-SAMPLES; SEDIMENT SAMPLES; SOIL; AM; MS; RADIONUCLIDES; ACTINIDES;
D O I
10.1021/acs.analchem.3c02526
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
As the most important plutonium isotopes, Pu-238, Pu-239, Pu-240, and Pu-241 arenormallymeasured by two to three techniques, which are tedious, time-consuming,and not suitable for rapid analysis in emergency situations. Recently,ICP-MS has become a competitive technique for the rapid measurementof Pu-239, Pu-240, and Pu-241. However,ICP-MS is difficult to measure Pu-238 due to the seriousisobaric interference of U-238. This work reports a rapidanalytical method to solve this problem for the simultaneous determinationof Pu-238, Pu-239, Pu-240, and Pu-241 using triple-quadrupole inductively coupled plasma massspectrometry (ICP-MS/MS) combined with chemical separation. Chemicalseparation achieved a high decontamination factor of 2.12 x 10(9) for the most critical interfering element, uranium, by usingtwo sequential TK200 columns. The interferences of (UH+)-U-238-H-1 and U-238(+) were effectivelyeliminated by using 12 mL/min He-6 mL/min NH3 asthe reaction gases in the octupole collision/reaction cell in ICP-MS/MS.Combined with chemical separation, the overall elimination efficiencyof (UH+)-U-238-H-1 reached 3.6 x 10(17), which is 10(5) times better than the reportedmethod. With the high U-238(+) elimination efficiencyof 1.12 x 10(4) in the ICP-MS/MS measurement, the overallremoval efficiency of U-238(+) reached 10(13), guaranteeing accurate determination of femtogram-level Pu-238 as well as Pu-239, Pu-240, and Pu-241 in the samples containing milligram-level U-238. Thedetection time is reduced to minutes, well fulfilling the requirementof rapid analysis. This method is validated by analyzing the standardreference material and the spiked samples.
引用
收藏
页码:12931 / 12939
页数:9
相关论文
共 50 条
  • [31] Determination of 239Pu, 240Pu, 241Pu and 242Pu at femtogram and attogram levels - evidence for the migration of fallout plutonium in an ombrotrophic peat bog profile
    Quinto, Francesca
    Hrnecek, Erich
    Krachler, Michael
    Shotyk, William
    Steier, Peter
    Winkler, Stephan R.
    ENVIRONMENTAL SCIENCE-PROCESSES & IMPACTS, 2013, 15 (04) : 839 - 847
  • [32] SIMULTANEOUS DETERMINATION OF PU-241,PU-238 AND PU-239,PU-240 IN LOW ACTIVITY ENVIRONMENTAL-SAMPLES
    HAKANEN, M
    JAAKKOLA, T
    KORPELA, H
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1984, 223 (2-3): : 382 - 385
  • [33] Determination of Ultra- Low Levels of 239Pu and 240Pu in Biological Samples
    Wang, Yong-Chang
    Zhang, Meng-Ting
    Hou, Xiao-Lin
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2024, 52 (05) : 706 - 716
  • [34] Multimodal analysis of prompt neutron spectra for 238Pu(sf), 240Pu(sf), 242Pu(sf) and 239Pu(nth,f)
    Ohsawa, T
    Horiguchi, T
    Mitsuhashi, M
    NUCLEAR PHYSICS A, 2000, 665 (1-2) : 3 - 12
  • [35] Simultaneous determination of radiocesium (135Cs, 137Cs) and plutonium (239Pu, 240Pu) isotopes in river suspended particles by ICP-MS/MS and SF-ICP-MS
    Cao, Liguo
    Zheng, Jian
    Tsukada, Hirofumi
    Pan, Shaoming
    Wang, Zhongtang
    Tagami, Keiko
    Uchida, Shigeo
    TALANTA, 2016, 159 : 55 - 63
  • [36] Alpha spectrometric determination of trace level of 239-240Pu and 238Pu in uranium compounds and solutions
    Bertaux, M
    Hanssens, A
    Madic, C
    RADIOCHIMICA ACTA, 1999, 84 (01) : 11 - 19
  • [37] 239Pu, 240Pu, and 241Am Determination in Hot Particles by Low Level Gamma-Spectrometry
    Jimenez-Ramos, M. G.
    Hurtado, S.
    Chamizo, E.
    Garcia-Tenorio, R.
    Leon-Vintro, L.
    Mitchell, P. I.
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2010, 44 (11) : 4247 - 4252
  • [38] In situ determination of 238Pu in the presence of uranium by triple quadrupole ICP-MS (ICP-QQQ-MS)
    Ling Ying Diane Tiong
    Shimin Tan
    Journal of Radioanalytical and Nuclear Chemistry, 2019, 322 : 399 - 406
  • [39] Determination of 90Sr and actinides (241Am, 239,240Pu, 238Pu) in nuclear waste samples
    Gerhart, P
    Prazsky, M
    Weilová, A
    Virágová, D
    ADVANCES IN DESTRUCTIVE AND NON-DESTRUCTIVE ANALYSIS FOR ENVIRONMENTAL MONITORING AND NUCLEAR FORENSICS, 2003, : 329 - 331
  • [40] Multi-isotopic determination of plutonium (239Pu, 240Pu, 241Pu and 242Pu) in marine sediments using sector-field inductively coupled plasma mass spectrometry
    Donard, O. F. X.
    Bruneau, F.
    Moldovan, M.
    Garraud, H.
    Epov, V. N.
    Boust, D.
    ANALYTICA CHIMICA ACTA, 2007, 587 (02) : 170 - 179