Rapid and Simultaneous Determination of 238Pu, 239Pu, 240Pu, and 241Pu in Samples with High-Level Uranium Using ICP-MS/MS and Extraction Chromatography

被引:6
|
作者
Huang, Zhao [1 ,3 ]
Hou, Xiaolin [1 ,2 ,5 ]
Zhao, Xue [1 ,2 ,4 ]
机构
[1] Chinese Acad Sci, Inst Earth Environm, Xian AMS Ctr, Shaanxi Key Lab Accelerator Mass Spectrometry,Stat, Xian 710061, Peoples R China
[2] Pilot Natl Lab Marine Sci & Technol Qingdao, Open Studio Ocean Continental Climate & Environm C, Qingdao 266061, Peoples R China
[3] Univ Chinese Acad Sci, Beijing 100049, Peoples R China
[4] Xian Inst Innovat Earth Environm Res, Xian 710061, Peoples R China
[5] Tech Univ Denmark, Dept Environm & Resource Engn, DK-4000 Roskilde, Denmark
基金
中国国家自然科学基金;
关键词
PLASMA-MASS SPECTROMETRY; PLUTONIUM ISOTOPES; PU ISOTOPES; ENVIRONMENTAL-SAMPLES; SEDIMENT SAMPLES; SOIL; AM; MS; RADIONUCLIDES; ACTINIDES;
D O I
10.1021/acs.analchem.3c02526
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
As the most important plutonium isotopes, Pu-238, Pu-239, Pu-240, and Pu-241 arenormallymeasured by two to three techniques, which are tedious, time-consuming,and not suitable for rapid analysis in emergency situations. Recently,ICP-MS has become a competitive technique for the rapid measurementof Pu-239, Pu-240, and Pu-241. However,ICP-MS is difficult to measure Pu-238 due to the seriousisobaric interference of U-238. This work reports a rapidanalytical method to solve this problem for the simultaneous determinationof Pu-238, Pu-239, Pu-240, and Pu-241 using triple-quadrupole inductively coupled plasma massspectrometry (ICP-MS/MS) combined with chemical separation. Chemicalseparation achieved a high decontamination factor of 2.12 x 10(9) for the most critical interfering element, uranium, by usingtwo sequential TK200 columns. The interferences of (UH+)-U-238-H-1 and U-238(+) were effectivelyeliminated by using 12 mL/min He-6 mL/min NH3 asthe reaction gases in the octupole collision/reaction cell in ICP-MS/MS.Combined with chemical separation, the overall elimination efficiencyof (UH+)-U-238-H-1 reached 3.6 x 10(17), which is 10(5) times better than the reportedmethod. With the high U-238(+) elimination efficiencyof 1.12 x 10(4) in the ICP-MS/MS measurement, the overallremoval efficiency of U-238(+) reached 10(13), guaranteeing accurate determination of femtogram-level Pu-238 as well as Pu-239, Pu-240, and Pu-241 in the samples containing milligram-level U-238. Thedetection time is reduced to minutes, well fulfilling the requirementof rapid analysis. This method is validated by analyzing the standardreference material and the spiked samples.
引用
收藏
页码:12931 / 12939
页数:9
相关论文
共 50 条
  • [21] ICP-MS analysis of plutonium activities and 240Pu/239Pu ratio in alpha spectrometry planchet deposits
    H. Michel
    M. E. Ketterer
    G. Barci-Funel
    Journal of Radioanalytical and Nuclear Chemistry, 2007, 273 : 485 - 490
  • [22] Determination of ultra-low level plutonium isotopes (239Pu,240pu) in environmental samples with high uranium
    Xing, Shan
    Zhang, Weichao
    Qiao, Jixin
    Hou, Xiaolin
    TALANTA, 2018, 187 : 357 - 364
  • [23] First determination of Pu isotopes (239Pu, 240Pu and 241Pu) in radioactive particles derived from Fukushima Daiichi Nuclear Power Plant accident
    Junya Igarashi
    Jian Zheng
    Zijian Zhang
    Kazuhiko Ninomiya
    Yukihiko Satou
    Miho Fukuda
    Youyi Ni
    Tatsuo Aono
    Atsushi Shinohara
    Scientific Reports, 9
  • [24] First determination of Pu isotopes (239Pu, 240Pu and 241Pu) in radioactive particles derived from Fukushima Daiichi Nuclear Power Plant accident
    Igarashi, Junya
    Zheng, Jian
    Zhang, Zijian
    Ninomiya, Kazuhiko
    Satou, Yukihiko
    Fukuda, Miho
    Ni, Youyi
    Aono, Tatsuo
    Shinohara, Atsushi
    SCIENTIFIC REPORTS, 2019, 9 (1)
  • [25] Preventing uranium hydride formation in standard uranium samples for determination of 239Pu by ICP-MS
    Vais, V
    Li, CS
    Cornett, J
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2004, 19 (09) : 1281 - 1283
  • [26] Rapid fingerprinting of 239Pu and 240Pu in environmental samples with high U levels using on-line ion chromatography coupled with high-sensitivity quadrupole ICP-MS detection
    Epov, Vladimir N.
    Evans, R. Douglas
    Zheng, Jian
    Donard, O. F. X.
    Yamada, Masatoshi
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2007, 22 (09) : 1131 - 1137
  • [27] DETERMINATION OF 239PU AND 240PU IN IRRADIATED URANIUM FUELS BY ALPHA AND GAMMA SPECTROMETRY
    MANNONE, F
    BRESESTI, M
    CAPORALI, G
    RADIOCHIMICA ACTA, 1968, 10 (3-4) : 124 - &
  • [28] Determination of 238Pu, 239+240Pu and 241Am in air filters
    Katarzyna Rzemek
    Andrzej Czerwiński
    Jakub Ośko
    Katarzyna Tymińska
    Małgorzata Dymecka
    Tomasz Pliszczyński
    Journal of Radioanalytical and Nuclear Chemistry, 2017, 311 : 1271 - 1276
  • [29] Determination of 238Pu, 239+240Pu and 241Am in air filters
    Rzemek, Katarzyna
    Czerwinski, Andrzej
    Osko, Jakub
    Tyminska, Katarzyna
    Dymecka, Magorzata
    Pliszczynski, Tomasz
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2017, 311 (02) : 1271 - 1276
  • [30] Large volume preconcentration and purification for determining the 240Pu/239Pu isotopic ratio and 238Pu/239+240Pu alpha-activity ratio in seawater
    Norisuye, K
    Okamura, K
    Sohrin, Y
    Hasegawa, H
    Nakanishi, T
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2005, 267 (01) : 183 - 193