Automatic reorientation by deep learning to generate short-axis SPECT myocardial perfusion images

被引:3
|
作者
Zhu, Fubao [1 ]
Wang, Guojie [1 ]
Zhao, Chen [2 ]
Malhotra, Saurabh [3 ,4 ]
Zhao, Min [5 ]
He, Zhuo [2 ]
Shi, Jianzhou
Jiang, Zhixin [8 ]
Zhou, Weihua [2 ,6 ,7 ]
机构
[1] Zhengzhou Univ Light Ind, Sch Comp & Commun Engn, Zhengzhou 450000, Henan, Peoples R China
[2] Michigan Technol Univ, Dept Appl Comp, Houghton, MI 49931 USA
[3] Cook Cty Hlth & Hosp Syst, Div Cardiol, Chicago, IL 60612 USA
[4] Rush Med Coll, Div Cardiol, Chicago, IL 60612 USA
[5] Cent South Univ, Xiangya Hosp, Dept Nucl Med, Changsha 410008, Peoples R China
[6] Michigan Technol Univ, Inst Comp & Cybersyst, Ctr Biocomp & Digital Hlth, 1400 Townsend Dr, Houghton, MI 49931 USA
[7] Michigan Technol Univ, Hlth Res Inst, 1400 Townsend Dr, Houghton, MI 49931 USA
[8] Nanjing Med Univ, Affiliated Hosp 1, Dept Cardiol, Guangzhou Rd 300, Nanjing 210029, Jiangsu, Peoples R China
基金
中国国家自然科学基金;
关键词
SPECT MPI; reorientation; deep learning; convolutional neural networks; VENTRICULAR LONG-AXIS;
D O I
10.1007/s12350-023-03226-2
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BackgroundSingle photon emission computed tomography (SPECT) myocardial perfusion images (MPI) can be displayed both in traditional short-axis (SA) cardiac planes and polar maps for interpretation and quantification. It is essential to reorient the reconstructed transaxial SPECT MPI into standard SA slices. This study is aimed to develop a deep-learning-based approach for automatic reorientation of MPI.MethodsA total of 254 patients were enrolled, including 226 stress SPECT MPIs and 247 rest SPECT MPIs. Fivefold cross-validation with 180 stress and 201 rest MPIs was used for training and internal validation; the remaining images were used for testing. The rigid transformation parameters (translation and rotation) from manual reorientation were annotated by an experienced nuclear cardiologist and used as the reference standard. A convolutional neural network (CNN) was designed to predict the transformation parameters. Then, the derived transform was applied to the grid generator and sampler in spatial transformer network (STN) to generate the reoriented image. A loss function containing mean absolute errors for translation and mean square errors for rotation was employed. A three-stage optimization strategy was adopted for model optimization: (1) optimize the translation parameters while fixing the rotation parameters; (2) optimize rotation parameters while fixing the translation parameters; (3) optimize both translation and rotation parameters together.ResultsIn the test set, the Spearman determination coefficients of the translation distances and rotation angles between the model prediction and the reference standard were 0.993 in X axis, 0.992 in Y axis, 0.994 in Z axis, 0.987 along X axis, 0.990 along Y axis and 0.996 along Z axis, respectively. For the 46 stress MPIs in the test set, the Spearman determination coefficients were 0.858 in percentage of profusion defect (PPD) and 0.858 in summed stress score (SSS); for the 46 rest MPIs in the test set, the Spearman determination coefficients were 0.9 in PPD and 0.9 in summed rest score (SRS).ConclusionsOur deep learning-based LV reorientation method is able to accurately generate the SA images. Technical validations and subsequent evaluations of measured clinical parameters show that it has great promise for clinical use.
引用
收藏
页码:1825 / 1835
页数:11
相关论文
共 50 条
  • [41] A new method incorporating deep learning with shape priors for left ventricular segmentation in myocardial perfusion SPECT images
    Zhu, Fubao
    Li, Longxi
    Zhao, Jinyu
    Zhao, Chen
    Tang, Shaojie
    Nan, Jiaofen
    Li, Yanting
    Zhao, Zhongqiang
    Shi, Jianzhou
    Chen, Zenghong
    Han, Chuang
    Jiang, Zhixin
    Zhou, Weihua
    COMPUTERS IN BIOLOGY AND MEDICINE, 2023, 160
  • [42] Deep Learning Based Automatic Left Ventricle Segmentation from the Transgastric Short-Axis View on Transesophageal Echocardiography: A Feasibility Study
    Tian, Yuan
    Qin, Wenting
    Zhao, Zihang
    Wang, Chunrong
    Tian, Yajie
    Zhang, Yuelun
    He, Kai
    Zhang, Yuguan
    Shen, Le
    Zhou, Zhuhuang
    Yu, Chunhua
    DIAGNOSTICS, 2024, 14 (15)
  • [43] Learning-Based Heart Coverage Estimation for Short-Axis Cine Cardiac MR Images
    Tarroni, Giacomo
    Oktay, Ozan
    Bai, Wenjia
    Schuh, Andreas
    Suzuki, Hideaki
    Passerat-Palmbach, Jonathan
    Glocker, Ben
    de Marvao, Antonio
    O'Regan, Declan
    Cook, Stuart
    Rueckert, Daniel
    FUNCTIONAL IMAGING AND MODELLING OF THE HEART, 2017, 10263 : 73 - 82
  • [44] Deep learning approximation of attenuation maps for myocardial perfusion SPECT with an IQ.SPECT collimator
    Huxohl, Tamino
    Patel, Gopesh
    Zabel, Reinhard
    Burchert, Wolfgang
    EJNMMI PHYSICS, 2023, 10 (01):
  • [45] Right ventricular strain and volume analyses through deep learning-based fully automatic segmentation based on radial long-axis reconstruction of short-axis cine magnetic resonance images
    Masateru Kawakubo
    Daichi Moriyama
    Yuzo Yamasaki
    Kohtaro Abe
    Kazuya Hosokawa
    Tetsuhiro Moriyama
    Pandji Triadyaksa
    Adi Wibowo
    Michinobu Nagao
    Hideo Arai
    Hiroshi Nishimura
    Toshiaki Kadokami
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2022, 35 : 911 - 921
  • [46] Right ventricular strain and volume analyses through deep learning-based fully automatic segmentation based on radial long-axis reconstruction of short-axis cine magnetic resonance images
    Kawakubo, Masateru
    Moriyama, Daichi
    Yamasaki, Yuzo
    Abe, Kohtaro
    Hosokawa, Kazuya
    Moriyama, Tetsuhiro
    Triadyaksa, Pandji
    Wibowo, Adi
    Nagao, Michinobu
    Arai, Hideo
    Nishimura, Hiroshi
    Kadokami, Toshiaki
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2022, 35 (06) : 911 - 921
  • [47] Deep learning–based denoising of low-dose SPECT myocardial perfusion images: quantitative assessment and clinical performance
    Narges Aghakhan Olia
    Alireza Kamali-Asl
    Sanaz Hariri Tabrizi
    Parham Geramifar
    Peyman Sheikhzadeh
    Saeed Farzanefar
    Hossein Arabi
    Habib Zaidi
    European Journal of Nuclear Medicine and Molecular Imaging, 2022, 49 : 1508 - 1522
  • [48] An Explainable Classification Method of SPECT Myocardial Perfusion Images in Nuclear Cardiology Using Deep Learning and Grad-CAM
    Papandrianos, Nikolaos, I
    Feleki, Anna
    Moustakidis, Serafeim
    Papageorgiou, Elpiniki, I
    Apostolopoulos, Ioannis D.
    Apostolopoulos, Dimitris J.
    APPLIED SCIENCES-BASEL, 2022, 12 (15):
  • [49] Deep learning-based attenuation map generation for myocardial perfusion SPECT
    Shi, Luyao
    Onofrey, John A.
    Liu, Hui
    Liu, Yi-Hwa
    Liu, Chi
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2020, 47 (10) : 2383 - 2395
  • [50] Deep learning-based attenuation map generation for myocardial perfusion SPECT
    Luyao Shi
    John A. Onofrey
    Hui Liu
    Yi-Hwa Liu
    Chi Liu
    European Journal of Nuclear Medicine and Molecular Imaging, 2020, 47 : 2383 - 2395