Automatic reorientation by deep learning to generate short-axis SPECT myocardial perfusion images

被引:3
|
作者
Zhu, Fubao [1 ]
Wang, Guojie [1 ]
Zhao, Chen [2 ]
Malhotra, Saurabh [3 ,4 ]
Zhao, Min [5 ]
He, Zhuo [2 ]
Shi, Jianzhou
Jiang, Zhixin [8 ]
Zhou, Weihua [2 ,6 ,7 ]
机构
[1] Zhengzhou Univ Light Ind, Sch Comp & Commun Engn, Zhengzhou 450000, Henan, Peoples R China
[2] Michigan Technol Univ, Dept Appl Comp, Houghton, MI 49931 USA
[3] Cook Cty Hlth & Hosp Syst, Div Cardiol, Chicago, IL 60612 USA
[4] Rush Med Coll, Div Cardiol, Chicago, IL 60612 USA
[5] Cent South Univ, Xiangya Hosp, Dept Nucl Med, Changsha 410008, Peoples R China
[6] Michigan Technol Univ, Inst Comp & Cybersyst, Ctr Biocomp & Digital Hlth, 1400 Townsend Dr, Houghton, MI 49931 USA
[7] Michigan Technol Univ, Hlth Res Inst, 1400 Townsend Dr, Houghton, MI 49931 USA
[8] Nanjing Med Univ, Affiliated Hosp 1, Dept Cardiol, Guangzhou Rd 300, Nanjing 210029, Jiangsu, Peoples R China
基金
中国国家自然科学基金;
关键词
SPECT MPI; reorientation; deep learning; convolutional neural networks; VENTRICULAR LONG-AXIS;
D O I
10.1007/s12350-023-03226-2
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BackgroundSingle photon emission computed tomography (SPECT) myocardial perfusion images (MPI) can be displayed both in traditional short-axis (SA) cardiac planes and polar maps for interpretation and quantification. It is essential to reorient the reconstructed transaxial SPECT MPI into standard SA slices. This study is aimed to develop a deep-learning-based approach for automatic reorientation of MPI.MethodsA total of 254 patients were enrolled, including 226 stress SPECT MPIs and 247 rest SPECT MPIs. Fivefold cross-validation with 180 stress and 201 rest MPIs was used for training and internal validation; the remaining images were used for testing. The rigid transformation parameters (translation and rotation) from manual reorientation were annotated by an experienced nuclear cardiologist and used as the reference standard. A convolutional neural network (CNN) was designed to predict the transformation parameters. Then, the derived transform was applied to the grid generator and sampler in spatial transformer network (STN) to generate the reoriented image. A loss function containing mean absolute errors for translation and mean square errors for rotation was employed. A three-stage optimization strategy was adopted for model optimization: (1) optimize the translation parameters while fixing the rotation parameters; (2) optimize rotation parameters while fixing the translation parameters; (3) optimize both translation and rotation parameters together.ResultsIn the test set, the Spearman determination coefficients of the translation distances and rotation angles between the model prediction and the reference standard were 0.993 in X axis, 0.992 in Y axis, 0.994 in Z axis, 0.987 along X axis, 0.990 along Y axis and 0.996 along Z axis, respectively. For the 46 stress MPIs in the test set, the Spearman determination coefficients were 0.858 in percentage of profusion defect (PPD) and 0.858 in summed stress score (SSS); for the 46 rest MPIs in the test set, the Spearman determination coefficients were 0.9 in PPD and 0.9 in summed rest score (SRS).ConclusionsOur deep learning-based LV reorientation method is able to accurately generate the SA images. Technical validations and subsequent evaluations of measured clinical parameters show that it has great promise for clinical use.
引用
收藏
页码:1825 / 1835
页数:11
相关论文
共 50 条
  • [31] A cascade approach for automatic segmentation of cardiac structures in short-axis cine-MR images using deep neural networks
    Santos da Silva, Italo Francyles
    Silva, Aristofanes Correa
    de Paiva, Anselmo Cardoso
    Gattass, Marcelo
    EXPERT SYSTEMS WITH APPLICATIONS, 2022, 197
  • [32] Fusion of short-axis and long-axis cardiac MR images
    Goshtasby, AA
    Turner, DA
    PROCEEDINGS OF THE IEEE WORKSHOP ON MATHEMATICAL METHODS IN BIOMEDICAL IMAGE ANALYSIS, 1996, : 202 - 211
  • [33] AUTOMATIC ANALYSIS OF LEFT VENTRICLE WALL THICKNESS USING SHORT-AXIS CINE CMR IMAGES
    Khalifa, F.
    Beache, G. M.
    Nitzken, M.
    Gimel'farb, G.
    Giridharan, G.
    El-Baz, A.
    2011 8TH IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: FROM NANO TO MACRO, 2011, : 1306 - 1309
  • [34] Evaluation of a Semi-automatic Right Ventricle Segmentation Method on Short-Axis MR Images
    Pinar Yilmaz
    Karel Wallecan
    Wisnumurti Kristanto
    Jean-Paul Aben
    Adriaan Moelker
    Journal of Digital Imaging, 2018, 31 : 670 - 679
  • [35] Impact of reorientation algorithms on quantitative myocardial SPECT perfusion imaging
    Haddad, M
    Porenta, G
    JOURNAL OF NUCLEAR MEDICINE, 1998, 39 (11) : 1864 - 1869
  • [36] Attenuation correction using deep learning for brain perfusion SPECT images
    Kenta Sakaguchi
    Hayato Kaida
    Shuhei Yoshida
    Kazunari Ishii
    Annals of Nuclear Medicine, 2021, 35 : 589 - 599
  • [37] Attenuation correction using deep learning for brain perfusion SPECT images
    Sakaguchi, Kenta
    Kaida, Hayato
    Yoshida, Shuhei
    Ishii, Kazunari
    ANNALS OF NUCLEAR MEDICINE, 2021, 35 (05) : 589 - 599
  • [38] FULLY AUTOMATIC SEGMENTATION OF SHORT-AXIS CARDIAC R USING MODIFIED DEEP LAYER AGGREGATION
    Li, Zhongyu
    Lou, Yixuan
    Yan, Zhennan
    Al'Aref, Subhi
    Min, James K.
    Axel, Leon
    Metaxas, Dimitris N.
    2019 IEEE 16TH INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (ISBI 2019), 2019, : 793 - 797
  • [39] Frequency specific denoising for myocardial perfusion SPECT using deep learning
    Du, Yu
    Sun, Jingzhang
    Li, Chien-Ying
    Wu, Tung-Hsin
    Yang, Bang-Hung
    Mok, Greta
    JOURNAL OF NUCLEAR MEDICINE, 2023, 64
  • [40] Anatomically-guided deep learning for left ventricle geometry generation with uncertainty quantification based on short-axis MR images
    Von Zuben, Andre
    Perotti, Luigi E.
    Viana, Felipe A. C.
    ENGINEERING APPLICATIONS OF ARTIFICIAL INTELLIGENCE, 2023, 121