Visual outcomes of non-diffractive extended-depth-of-focus and enhanced monofocal intraocular lenses: A case-control study

被引:12
|
作者
Sabur, Huri [1 ]
Unsal, Ugur [2 ]
机构
[1] Univ Hlth Sci, Dept Ophthalmol, Diskapi Yildirim Beyazit Training & Res Hosp, Ankara, Turkey
[2] Batigoz Eye Hlth Ctr, Dept Ophthalmol, Izmir, Turkey
关键词
Cataract surgery; intraocular lens; AcrySof IQ Vivity; EDoF; monofocal; Tecnis Eyhance; QUALITY;
D O I
10.1177/11206721221125004
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Objective To compare the visual outcomes of a non-diffractive extended-depth-of-focus (EDoF) intraocular lens (IOL) with an enhanced monofocal IOL. Methods We evaluated 76 eyes from 38 patients who had undergone bilateral cataract surgery with implantation of either an EDoF IOL (AcrySof IQ Vivity, n = 40 eyes) or an enhanced monofocal IOL (Tecnis Eyhance, n = 36 eyes). Objective refraction, monocular and binocular uncorrected and corrected distance visual acuity (UDVA, CDVA), uncorrected and distance-corrected intermediate visual acuity (UIVA, DCIVA), uncorrected and distance-corrected near visual acuity (UNVA, DCNVA), binocular defocus curves, contrast sensitivity, halo and glare perception, and spectacle independence were compared. Results Monocular and binocular UDVA, CDVA, UIVA, and DCIVA were comparable in both groups, whereas UNVA and DCNVA were significantly better with the Vivity group than with the Eyhance group. The two groups had no statistically significant difference regarding photopic and scotopic contrast sensitivities or halo and glare perception. Compared to the Eyhance IOL, the Vivity IOL had a larger landing zone in the defocus curve and provided higher spectacle independence for near vision. Conclusion Both the AcrySof IQ Vivity and Tecnis Eyhance IOLs had excellent distant and intermediate visual acuity, while the former had more satisfactory near vision outcomes with greater spectacle independence rate. No differences were obtained between two IOLs in terms of patient satisfaction and visual disturbances such as halo and glare.
引用
收藏
页码:262 / 268
页数:7
相关论文
共 50 条
  • [11] Comparison of visual performance between bifocal and extended-depth-of-focus intraocular lenses
    Tabuchi, Hitoshi
    Tanabe, Hirotaka
    Shirakami, Tomoki
    Takase, Kosuke
    Shojo, Tomohiro
    Yamauchi, Tomofusa
    PLOS ONE, 2023, 18 (07):
  • [12] Comparing an Advanced Monofocal With a Non-diffractive Extended Depth of Focus Intraocular Lens Using a Mini-Monovision Approach
    Zeilinger, Johannes
    Kronschlaeger, Martin
    Schlatter, Andreas
    Georgiev, Stefan
    Ruiss, Manuel
    Pilwachs, Caroline
    Findl, Oliver
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2025, 271 : 86 - 95
  • [13] Real-world visual outcomes of a non-diffractive extended depth of focus intraocular lens implanted in Australian sites
    Mangat, Simran
    Sabel, Robyn
    Rose, Monique
    Perez-Vives, Caridad
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2023, 51 (09): : 1015 - 1016
  • [14] Positioning of enhanced monofocal intraocular lenses between conventional monofocal and extended depth of focus lenses: a scoping review
    Joaquín Fernández
    Carlos Rocha-de-Lossada
    Francisco Zamorano-Martín
    Marina Rodríguez-Calvo-de-Mora
    Manuel Rodríguez-Vallejo
    BMC Ophthalmology, 23
  • [15] Influence of visual field on visual acuity and contrast sensitivity of glaucomatous eyes with monofocal and diffractive extended depth -of focus intraocular lenses
    Minami, Keiichiro
    Ota, Yuka
    Taira, Yoko
    Bissen-Miyajima, Hiroko
    Takemura, Ryo
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2024, 65 (07)
  • [16] Positioning of enhanced monofocal intraocular lenses between conventional monofocal and extended depth of focus lenses: a scoping review
    Fernandez, Joaquin
    Rocha-de-Lossada, Carlos
    Zamorano-Martin, Francisco
    Rodriguez-Calvo-de-Mora, Marina
    Rodriguez-Vallejo, Manuel
    BMC OPHTHALMOLOGY, 2023, 23 (01)
  • [17] Visual function in eyes with diffractive extended depth-of-focus and monofocal intraocular lenses: 2-year comparison
    Hisai, Takahiro
    Takada, Keita
    Tokuda, Shota
    Nejima, Ryohei
    Mori, Yosai
    Minami, Keiichiro
    Miyata, Kazunori
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2023, 261 (09) : 2567 - 2573
  • [18] Visual function in eyes with diffractive extended depth-of-focus and monofocal intraocular lenses: 2-year comparison
    Takahiro Hisai
    Keita Takada
    Shota Tokuda
    Ryohei Nejima
    Yosai Mori
    Keiichiro Minami
    Kazunori Miyata
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2023, 261 : 2567 - 2573
  • [19] Postoperative Visual Function of Extended Depth-of-Focus Intraocular Lenses Versus Monofocal Lenses
    Komatsu, Koji
    Masuda, Yoichiro
    Tachibana, Sei
    Sano, Kei
    Iida, Masanobu
    Ichihara, Kosuke
    Oki, Tetutaro
    Fukai, Kota
    Tatemichi, Masayuki
    Nakano, Tadashi
    JOURNAL OF REFRACTIVE SURGERY, 2024, 40 (07) : E499 - +
  • [20] Evaluation of Visual and Patient-Reported Outcomes, Spectacle Dependence after Bilateral Implantation with a Non-Diffractive Extended Depth of Focus Intraocular Lens Compared to Other Intraocular Lenses
    Dolowiec-Kwapisz, Anna
    Piotrowska, Halina
    Misiuk-Hojlo, Marta
    JOURNAL OF CLINICAL MEDICINE, 2022, 11 (17)