Biomechanical Research of Three Parallel Cannulated Compression Screws in Oblique Triangle Configuration for Fixation of Femoral Neck Unstable Fractures

被引:1
|
作者
Zhang, Ru-Yi [1 ]
Zhang, Wu-Peng [2 ,3 ,4 ]
Yang, Guang-Min [5 ]
Wang, Dao-Feng [6 ]
Su, Peng [1 ]
Zhang, Yi [1 ]
Nie, Shao-Bo [2 ,3 ]
Li, Jia [2 ,3 ]
Zhao, Zhe [5 ,7 ]
Li, Jian-Tao [2 ,3 ,7 ]
Zhang, Li-Cheng [2 ,3 ,7 ]
Tang, Pei-Fu [2 ,3 ]
机构
[1] Capital Med Univ, Beijing Shijingshan Hosp, Shijingshan Teaching Hosp, Dept Orthopaed, Beijing, Peoples R China
[2] Chinese Peoples Liberat Army Gen Hosp, Med Ctr 4, Dept Orthoped, Beijing, Peoples R China
[3] Natl Clin Res Ctr Orthoped Sports Med & Rehabil, Beijing, Peoples R China
[4] Nankai Univ, Sch Med, Tianjin, Peoples R China
[5] Tsinghua Univ, Sch Clin Med, Beijing Tsinghua Changgung Hosp, Dept Orthopaed, Beijing, Peoples R China
[6] Capital Med Univ, Beijing Jishuitan Hosp, Dept Sports Med, Sports Med Serv, Beijing, Peoples R China
[7] Chinese Peoples Liberat Army Gen Hosp, Med Ctr 4, Dept Orthoped, Beijing, Peoples R China
关键词
Biomechanics; Cannulated Compression Screw; Femoral Neck Fracture; Oblique Triangle; Spatial Configuration; INTERNAL-FIXATION; NAIL;
D O I
10.1111/os.14004
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objective: Surgical treatment with internal fixation, specifically percutaneous fixation with three cannulated compression screws (CCSs), is the preferred choice for young and middle-aged patients. The mechanical advantage of the optimal spatial configuration with three screws provides maximum dispersion and cortical support. We suspect that the spatial proportion of the oblique triangle configuration (OTC) in the cross-section of the femoral neck isthmus (FNI) may significantly improve shear and fatigue resistance of the fixed structure, thereby stabilizing the internal fixation system in femoral neck fracture (FNF). This study aims to explore the mechanical features of OTC and provide a mechanical basis for its clinical application. Methods: Twenty Sawbone femurs were prepared as Pauwels type III FNF models and divided equally into two fixation groups: OTC and inverted equilateral triangle configuration (IETC). Three 7.3 mm diameter cannulated compression screws (CCSs) were used for fixation. The specimens of FNF after screw internal fixation were subjected to static loading and cyclic loading tests, respectively, with five specimens for each test. Axial stiffness, 5 mm failure load, ultimate load, shear displacement, and frontal rotational angle of two fragments were evaluated. In the cyclic loading test, the load sizes were 700 N, 1400 N, and 2100 N, respectively, and the fracture end displacement was recorded. Results were presented as means +/- SD. Data with normal distributions were compared by the Student's t test. Results: In the static loading test, the axial stiffness, ultimate load, shear displacement, and frontal rotational angle of two fragments were (738.64 vs. 620.74) N/mm, (2957.61 vs. 2643.06) N, (4.67 vs. 5.39) mm, and (4.01 vs. 5.52)degrees (p < 0.05), respectively. Comparison between the femoral head displacement after 10,000 cycles of 700N cyclic loading and total displacement after 20,000 cycles of 700-1400N cyclic loading showed the OTC group was less than the IETC group (p < 0.05). A comparison of femoral head displacement after 10,000 cycles of 1400N and 2100N cycles and total displacement after 30,000 cycles of 700-2100N cycles showed the OTC group was less than another group, but the difference was not significant (p > 0.05). Conclusion: When three CCSs are inserted in parallel to fix FNF, the OTC of three screws has obvious biomechanical advantages, especially in shear resistance and early postoperative weight-bearing, which provides a mechanical basis for clinical selection of ideal spatial configuration for unstable FNF.
引用
收藏
页码:953 / 964
页数:12
相关论文
共 50 条
  • [11] In Vitro Biomechanical Study of Femoral Neck Fracture Fixation with Two or Three Cannulated Screws in Dogs
    Caldeira, Fatima Maria C.
    Rahal, Sheila C.
    Cassanego, Guilherme R.
    Ribeiro, Celso R.
    Serrato, Sergio A. A.
    Mele, Carlos E.
    Masseran, Paulo
    VETERINARY AND COMPARATIVE ORTHOPAEDICS AND TRAUMATOLOGY, 2025, 38 (01) : 18 - 24
  • [12] A new angle and its relationship with early fixation failure of femoral neck fractures treated with three cannulated compression screws
    Zhang, Y. L.
    Zhang, W.
    Zhang, C. Q.
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2017, 103 (02) : 229 - 234
  • [13] Cannulated screws fixation as an alternative treatment of femoral neck osteoporotic fractures
    Ciesielczyk, B
    Tuchocka-Piotrowska, A
    ANNALS OF THE RHEUMATIC DISEASES, 2005, 64 : 516 - +
  • [14] Biomechanical Evaluation of the Femoral Neck System in Unstable Pauwels III Femoral Neck Fractures: A Comparison with the Dynamic Hip Screw and Cannulated Screws
    Stoffel, Karl
    Zderic, Ivan
    Gras, Florian
    Sommer, Christoph
    Eberli, Ursula
    Mueller, David
    Oswald, Martin
    Gueorguiev, Boyko
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2017, 31 (03) : 131 - 137
  • [15] Biomechanical analysis of a new cannulated screw for unstable femoral neck fractures
    Chen, Zhigang
    Chen, Feiyang
    Xu, Xinbao
    Li, Xin
    Cui, Haidong
    Zhang, Wen
    Jiang, Dong
    Zhang, Feixiang
    Chen, Yinbing
    Zhou, Shiran
    Lyu, Shujun
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2024, 12
  • [16] Comparison of oblique triangular configuration and inverted equilateral triangular configuration of three cannulated screws in treating unstable femoral neck fracture: A finite element analysis
    Zhang, Ru-Yi
    Li, Jian-Tao
    Zhao, Jing-Xin
    Zhao, Zhe
    Zhang, Li-Cheng
    Yun, Cai
    Su, Xiu-Yun
    Tang, Pei-Fu
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2022, 53 (02): : 353 - 361
  • [17] Internal fixation using fully threaded cannulated compression screws for fresh femoral neck fractures in adults
    Kai-xuan Yuan
    Fan Yang
    Kai Fu
    Dao-yu Zhu
    Chen-yi Jiang
    Dong-xu Jin
    Ze-hao Wang
    Xiao-yuan Peng
    You-Shui Gao
    Peng-bo Luo
    Journal of Orthopaedic Surgery and Research, 17
  • [18] Internal fixation using fully threaded cannulated compression screws for fresh femoral neck fractures in adults
    Yuan, Kai-xuan
    Yang, Fan
    Fu, Kai
    Zhu, Dao-yu
    Jiang, Chen-yi
    Jin, Dong-xu
    Wang, Ze-hao
    Peng, Xiao-yuan
    Gao, You-Shui
    Luo, Peng-bo
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2022, 17 (01)
  • [19] Biomechanical evaluation of the expansive cannulated screw for fixation of femoral neck fractures
    Zhang, Yang
    Tian, Li
    Yan, Yabo
    Sang, Hongxun
    Ma, Zhensheng
    Jie, Qiang
    Lei, Wei
    Wu, Zixiang
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2011, 42 (11): : 1372 - 1376
  • [20] Femoral Neck System versus Three Cannulated Screws for Fixation of Femoral Neck Fractures in Younger Patients: A Retrospective Cohort Study
    Yan, Shuang G.
    Cui, Yiliang
    Li, Di
    Liu, Fanxiao
    Hua, Xingyi
    Schmidutz, Florian
    JOURNAL OF INVESTIGATIVE SURGERY, 2023, 36 (01)