Radiomic analysis of preoperative magnetic resonance imaging for the prediction of pituitary adenoma consistency

被引:6
|
作者
Mendi, Boekebatur Ahmet Rasit [1 ]
Batur, Halitcan [1 ]
Cay, Nurdan [2 ]
Cakir, Banu Topcu [3 ]
机构
[1] Nigde Omer Halisdemir Univ Training & Res Hosp, Dept Radiol, Hastaneler Cad, TR-51100 Nigde, Turkiye
[2] Ankara Yildirim Beyazit Univ, Ankara City Hosp, Fac Med, Dept Radiol, Ankara, Turkiye
[3] Hlth Sci Univ, Gulhane Training & Res Hosp, Fac Med, Dept Radiol, Ankara, Turkiye
关键词
Pituitary adenoma; radiomics; magnetic resonance imaging; machine learning; APPARENT DIFFUSION-COEFFICIENT; TUMOR CONSISTENCY; EXTERNAL VALIDATION; MACROADENOMAS; MRI; FEATURES;
D O I
10.1177/02841851231174462
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background The consistency of pituitary adenomas affects the course of surgical treatment. Purpose To evaluate the diagnostic capabilities of radiomics based on T1-weighted (T1W) and T2-weighted (T2W) magnetic resonance imaging (MRI) in conjunction with two machine-learning (ML) techniques (support vector machine [SVM] and random forest classifier [RFC]) for assessing the consistency of pituitary adenomas. Material and Methods The institutional database was retrospectively scanned for patients who underwent surgical excision of pituitary adenomas. Surgical notes were accepted as a reference for the adenoma consistency. Radiomics analysis was performed on preoperative coronal 3.0T T1W and T2W images. First- and second-order parameters were calculated. Inter-observer reproducibility was assessed with Spearman's Correlation (rho) and intra-observer reproducibility was evaluated with the intraclass correlation coefficient (ICC). Least absolute shrinkage and selection operator (LASSO) was used for dimensionality reduction. SVM and RFC were used as ML methods. Results A total of 52 patients who produced 206 regions of interest (ROIs) were included. Twenty adenomas that produced 88 ROIs had firm consistency. There was both inter-observer and intra-observer reproducibility. Ten parameters that were based on T2W images with high discriminative power and without correlation were chosen by LASSO. The diagnostic performance of SVM and RFC was as follows: sensitivity = 95.580% and 92.950%, specificity = 83.670% and 88.420%, area under the curve = 0.956 and 0.904, respectively. Conclusion Radiomics analysis based on T2W MRI combined with various ML techniques, such as SVM and RFC, can provide preoperative information regarding pituitary adenoma consistency with high diagnostic accuracy.
引用
收藏
页码:2470 / 2478
页数:9
相关论文
共 50 条
  • [1] Predicting pituitary adenoma consistency with preoperative magnetic resonance elastography
    Cohen-Cohen, Salomon
    Helal, Ahmed
    Yin, Ziying
    Ball, Matthew K.
    Ehman, Richard L.
    Van Gompel, Jamie J.
    Huston, John, III
    JOURNAL OF NEUROSURGERY, 2022, 136 (05) : 1356 - 1363
  • [2] Prediction of Consistency of Pituitary Adenomas by Magnetic Resonance Imaging
    Smith, Kyle A.
    Leever, John D.
    Chamoun, Roukoz B.
    JOURNAL OF NEUROLOGICAL SURGERY PART B-SKULL BASE, 2015, 76 (05) : 340 - 343
  • [3] Prediction of consistency of meningiomas with preoperative magnetic resonance imaging
    Yamaguchi, N
    Kawase, T
    Sagoh, M
    Ohira, T
    Shiga, H
    Toya, S
    SURGICAL NEUROLOGY, 1997, 48 (06): : 579 - 583
  • [4] Virtual magnetic resonance elastography has the feasibility to evaluate preoperative pituitary adenoma consistency
    Lagerstrand, Kerstin
    Gaedes, Nicholas
    Eriksson, Stig
    Farahmand, Dan
    De Coursey, Erica
    Johansson, Gudmundur
    Jonsson, Lars
    Skoglund, Thomas
    PITUITARY, 2021, 24 (04) : 530 - 541
  • [5] Virtual magnetic resonance elastography has the feasibility to evaluate preoperative pituitary adenoma consistency
    Kerstin Lagerstrand
    Nicholas Gaedes
    Stig Eriksson
    Dan Farahmand
    Erica De Coursey
    Gudmundur Johansson
    Lars Jönsson
    Thomas Skoglund
    Pituitary, 2021, 24 : 530 - 541
  • [6] Prediction of consistency of meningiomas with preoperative magnetic resonance imaging - Commentary
    Philippon, J
    SURGICAL NEUROLOGY, 1997, 48 (06): : 583 - 583
  • [7] Methods of preoperative prediction of pituitary adenoma consistency: a systematic review
    Cerny, Martin
    Sedlak, Vojtech
    Lesakova, Veronika
    Francuz, Peter
    Netuka, David
    NEUROSURGICAL REVIEW, 2023, 46 (01)
  • [8] Methods of preoperative prediction of pituitary adenoma consistency: a systematic review
    Martin Černý
    Vojtěch Sedlák
    Veronika Lesáková
    Peter Francůz
    David Netuka
    Neurosurgical Review, 46
  • [9] MACHINE LEARNING-BASED RADIOMIC MODEL USING MULTIPARAMETRIC MAGNETIC RESONANCE IMAGING FOR PREDICTION OF POSTOPERATIVE VISUAL RECOVERY OF PITUITARY ADENOMA PATIENTS
    Zhang, Y.
    Chen, C.
    Xu, J.
    NEURO-ONCOLOGY, 2023, 25
  • [10] Magnetic Resonance Fingerprinting for Preoperative Meningioma Consistency Prediction
    Bai, Yan
    Zhang, Rui
    Zhang, Xianchang
    Wang, Xinhui
    Nittka, Mathias
    Koerzdoerfer, Gregor
    Gong, Qiyong
    Wang, Meiyun
    ACADEMIC RADIOLOGY, 2022, 29 (08) : E157 - E165