Radiomic analysis of preoperative magnetic resonance imaging for the prediction of pituitary adenoma consistency

被引:6
|
作者
Mendi, Boekebatur Ahmet Rasit [1 ]
Batur, Halitcan [1 ]
Cay, Nurdan [2 ]
Cakir, Banu Topcu [3 ]
机构
[1] Nigde Omer Halisdemir Univ Training & Res Hosp, Dept Radiol, Hastaneler Cad, TR-51100 Nigde, Turkiye
[2] Ankara Yildirim Beyazit Univ, Ankara City Hosp, Fac Med, Dept Radiol, Ankara, Turkiye
[3] Hlth Sci Univ, Gulhane Training & Res Hosp, Fac Med, Dept Radiol, Ankara, Turkiye
关键词
Pituitary adenoma; radiomics; magnetic resonance imaging; machine learning; APPARENT DIFFUSION-COEFFICIENT; TUMOR CONSISTENCY; EXTERNAL VALIDATION; MACROADENOMAS; MRI; FEATURES;
D O I
10.1177/02841851231174462
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background The consistency of pituitary adenomas affects the course of surgical treatment. Purpose To evaluate the diagnostic capabilities of radiomics based on T1-weighted (T1W) and T2-weighted (T2W) magnetic resonance imaging (MRI) in conjunction with two machine-learning (ML) techniques (support vector machine [SVM] and random forest classifier [RFC]) for assessing the consistency of pituitary adenomas. Material and Methods The institutional database was retrospectively scanned for patients who underwent surgical excision of pituitary adenomas. Surgical notes were accepted as a reference for the adenoma consistency. Radiomics analysis was performed on preoperative coronal 3.0T T1W and T2W images. First- and second-order parameters were calculated. Inter-observer reproducibility was assessed with Spearman's Correlation (rho) and intra-observer reproducibility was evaluated with the intraclass correlation coefficient (ICC). Least absolute shrinkage and selection operator (LASSO) was used for dimensionality reduction. SVM and RFC were used as ML methods. Results A total of 52 patients who produced 206 regions of interest (ROIs) were included. Twenty adenomas that produced 88 ROIs had firm consistency. There was both inter-observer and intra-observer reproducibility. Ten parameters that were based on T2W images with high discriminative power and without correlation were chosen by LASSO. The diagnostic performance of SVM and RFC was as follows: sensitivity = 95.580% and 92.950%, specificity = 83.670% and 88.420%, area under the curve = 0.956 and 0.904, respectively. Conclusion Radiomics analysis based on T2W MRI combined with various ML techniques, such as SVM and RFC, can provide preoperative information regarding pituitary adenoma consistency with high diagnostic accuracy.
引用
收藏
页码:2470 / 2478
页数:9
相关论文
共 50 条
  • [31] Predicting Subtype of Growth Hormone Pituitary Adenoma based on Magnetic Resonance Imaging Characteristics
    Liu, Chen-Xi
    Wang, Sheng-Zhong
    Heng, Li-Jun
    Han, Yu
    Ma, Yu-Hui
    Yan, Lin-Feng
    Yu, Ying
    Wang, Wen
    Hu, Yu-Chuan
    Cui, Guang-Bin
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2022, 46 (01) : 124 - 130
  • [32] Development and validation of a prediction model for consistency of pituitary adenoma: the PiTCon score
    Cancela, Alberto Acitores
    Berrocal, Victor Rodriguez
    Arias, Hector Pian
    Gomez, Juan Jose Diez
    Lozano, Pedro Iglesias
    ACTA NEUROCHIRURGICA, 2024, 166 (01)
  • [33] MAGNETIC RESONANCE RADIOMIC ANALYSIS FOR THE PREDICTION OF GRAFT FAILURE IN PATIENTS WITH KIDNEY TRANSPLANTATION
    Fontana, Francesco
    Alfano, Gaetano
    Monelli, Filippo
    Besutti, Giulia
    Trojani, Valeria
    Donati, Gabriele
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 2023, 38 : I932 - I932
  • [34] Vanishing pituitary mass revealed by timely magnetic resonance imaging: examples of spontaneous resolution of nonfunctioning pituitary adenoma
    Yoshino, A
    Katayama, Y
    Watanabe, T
    Hirota, H
    ACTA NEUROCHIRURGICA, 2005, 147 (03) : 253 - 257
  • [35] Prediction of microvascular invasion in hepatocellular carcinoma with preoperative imaging radiomic analysis: Is it ready for prime time?
    Gang Xu
    Hua-Yu Yang
    Hai-Feng Xu
    Hepatobiliary & Pancreatic Diseases International, 2019, 18 (03) : 289 - 290
  • [36] Magnetic Resonance Imaging Features of the Sphenoid Sinus in Patients with Non-Functioning Pituitary Adenoma
    Ciurea, Mircea-Viorel
    Florian, Ioan Stefan
    Lenghel, Manuela
    Petea-Balea, Diana-Raluca
    Roman, Alexandra
    Albu, Silviu
    MEDICINA-LITHUANIA, 2024, 60 (05):
  • [37] Aggressive giant pituitary adenoma presenting as a nasopharyngeal mass: magnetic resonance imaging and pathologic findings
    Ravichandran, TP
    Bakshi, R
    Heffner, RR
    Gibbons, KJ
    Bates, VE
    Durante, DJ
    Kinkel, WR
    JOURNAL OF NEURO-ONCOLOGY, 1999, 41 (01) : 71 - 75
  • [38] Aggressive Giant Pituitary Adenoma Presenting as a Nasopharyngeal Mass: Magnetic Resonance Imaging and Pathologic Findings
    Thulasiraman P. Ravichandran
    Rohit Bakshi
    Reid R. Heffner
    Kevin J. Gibbons
    Vernice E. Bates
    David J. Durante
    William R. Kinkel
    Journal of Neuro-Oncology, 1999, 41 : 71 - 75
  • [39] Prediction of microvascular invasion in hepatocellular carcinoma with preoperative imaging radiomic analysis: Is it ready for prime time?
    Xu, Gang
    Yang, Hua-Yu
    Xu, Hai-Feng
    HEPATOBILIARY & PANCREATIC DISEASES INTERNATIONAL, 2019, 18 (03) : 289 - 290
  • [40] Magnetic resonance imaging of cavernous sinus invasion by pituitary adenoma: Diagnostic criteria and surgical findings
    Vieira, JO
    Cukiert, A
    Liberman, B
    ARQUIVOS DE NEURO-PSIQUIATRIA, 2004, 62 (2B) : 437 - 443