共 50 条
A sensitive sandwich-type electrochemical immunosensor using nitrogen-doped graphene/metal-organic framework-derived CuMnCoOx and Au/MXene for the detection of breast cancer biomarker
被引:5
|作者:
Sakthivel, Rajalakshmi
[1
]
Lin, Yu-Chien
[1
,2
]
Yu, Min-Chin
[1
]
Dhawan, Udesh
[3
]
Liu, Xinke
[4
,5
]
Chen, Jung-Chih
[2
,6
,7
,8
]
Tung, Ching-Wei
[9
]
Chung, Ren-Jei
[1
,10
,11
]
机构:
[1] Natl Taipei Univ Technol Taipei Tech, Dept Chem Engn & Biotechnol, Taipei, Taiwan
[2] Natl Yang Ming Chiao Tung Univ, Inst Biomed Engn, Hsinchu, Taiwan
[3] Univ Glasgow, Mazumdar Shaw Adv Res Ctr, James Watt Sch Engn, Ctr Cellular Microenvironm,Div Biomed Engn, Glasgow City, Scotland
[4] Shenzhen Univ, Chinese Engn & Res Inst Microelect, Coll Mat Sci & Engn, Shenzhen, Peoples R China
[5] Natl Univ Singapore, Dept Elect & Comp Engn, Singapore, Singapore
[6] Natl Yang Ming Chiao Tung Univ, Dept Elect & Elect Engn, Hsinchu, Taiwan
[7] Catholic Mercy Hosp, Catholic Mercy Med Fdn, Hsinchu, Taiwan
[8] Natl Yang Ming Chiao Tung Univ, Med Device Innovat & Translat Ctr, Taipei, Taiwan
[9] Ming Chi Univ Technol, Dept Mat Engn, New Taipei City, Taiwan
[10] Natl Taipei Univ Technol Taipei Tech, High value Biomat Res & Commercializat Ctr, Taipei, Taiwan
[11] Natl Taipei Univ Technol Taipei Tech, Dept Chem Engn & Biotechnol, 1 Sect 3,Zhongxiao E Rd, Taipei 10608, Taiwan
关键词:
Sandwich-type electrochemical immunosensor;
Trimetallic oxide CuMnCoO x;
N -doped graphene;
Ti 3 C 2 T x MXene;
Breast cancer biomarker HER2-ECD;
THERMAL-STABILITY;
CLINICAL UTILITY;
NANOPARTICLES;
COMPOSITES;
NANOSHEETS;
D O I:
10.1016/j.colsurfb.2024.113755
中图分类号:
Q6 [生物物理学];
学科分类号:
071011 ;
摘要:
In terms of cancer-related deaths among women, breast cancer (BC) is the most common. Clinically, human epidermal growth receptor 2 (HER2) is one of the most commonly used diagnostic biomarkers for facilitating BC cell proliferation and malignant growth. In this study, a disposable gold electrode (DGE) modified with gold nanoparticle-decorated Ti(3)C(2)Tx (Au/MXene) was utilized as a sensing platform to immobilize the capturing antibody (Ab(1)/Au/MXene). Subsequently, nitrogen -doped graphene (NG) with a metal-organic framework (MOF)-derived copper-manganese-cobalt oxide, tagged as NG/CuMnCoOx, was used as a probe to label the detection antibody (Ab2). A sandwich-type immunosensor (NG/CuMnCoOx/Ab(2)/HER2-ECD /Ab(1)/Au/MXene/ DGE) was developed to quantify HER2-ECD. NG/CuMnCoOx enhances the conductivity, electrocatalytic active sites, and surface area to immobilize Ab(2). In addition, Au/MXene facilitates electron transport and captures more Ab(1) on its surface. Under optimal conditions, the resultant immunosensor displayed an excellent linear range of 0.0001 to 50.0 ng. mL(-1). The detection limit was 0.757 pg & sdot;mL(-1) with excellent selectivity, appreciable reproducibility, and high stability. Moreover, the applicability for determining HER2-ECD in human serum samples indicates its ability to monitor tumor markers clinically.
引用
收藏
页数:14
相关论文