When one equals two: Chemometrics turns Mossbauer spectrometer into X-ray fluorescence one

被引:0
|
作者
Semenov, Valentin [1 ,2 ]
Grigoriev, Mikhail [1 ]
Kirsanov, Dmitry [1 ]
Panchuk, Vitaly [1 ,2 ]
机构
[1] St Petersburg State Univ, Inst Chem, St Petersburg, Russia
[2] RAS, Inst Analyt Instrumentat, St Petersburg, Russia
基金
俄罗斯科学基金会;
关键词
EDXRF; Mossbauer spectroscopy; Chemometrics; X-ray fluorescence; SPECTROSCOPY;
D O I
10.1016/j.sab.2024.106878
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
Here we explore the feasibility of using classical Mossbauer spectroscopy setup in scattering geometry to assess the elemental composition of samples using characteristic X-ray fluorescence. Even though, the scintillation detector of Mossbauer spectrometer yields rather low spectral resolution spectra, this can be effectively compensated using chemometric data processing. This hypothesis was first checked with simulated spectra of steel samples and afterwards was confirmed with real experiments. The results of Ti, Cr, Mn, Ni, Nb and Mo quantification in real steel samples obtained from Mossbauer spectrometer were compared with those obtained with commercial energy dispersive X-ray fluorescence (EDXRF) spectrometer. In case of Ti, Cr and Ni the accuracy attained with Mossbauer spectrometer was similar to that of an ordinary commercial EDXRF device.
引用
收藏
页数:6
相关论文
共 50 条
  • [41] Honouring the two Braggs: the first X-ray crystal structure and the first X-ray spectrometer
    Helliwell, John R.
    CRYSTALLOGRAPHY REVIEWS, 2013, 19 (03) : 108 - 116
  • [42] Mossbauer and X-ray fluorescence measurements of authentic and counterfeited banknote pigments
    Rusanov, V.
    Chakarova, K.
    Winkler, H.
    Trautwein, A. X.
    DYES AND PIGMENTS, 2009, 81 (03) : 254 - 258
  • [43] Does chemometrics work for matrix effects correction in X-ray fluorescence analysis?
    Aidene, Soraya
    Khaydukova, Maria
    Pashkova, Galina
    Chubarov, Victor
    Savinov, Sergey
    Semenov, Valentin
    Kirsanov, Dmitry
    Panchuk, Vitaly
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2021, 185
  • [44] Determination of the emission spectrum of an X-ray tube of a wavelength-dispersive series X-ray fluorescence spectrometer
    K. V. Oskolok
    O. V. Monogarova
    Journal of Analytical Chemistry, 2008, 63 : 1176 - 1181
  • [45] Determination of the emission spectrum of an X-ray tube of a wavelength-dispersive series X-ray fluorescence spectrometer
    Oskolok, K. V.
    Monogarova, O. V.
    JOURNAL OF ANALYTICAL CHEMISTRY, 2008, 63 (12) : 1176 - 1181
  • [46] Transmission calculations for one- and two-dimensional x-ray waveguides
    Jark, W
    Di Fonzo, S
    DESIGN AND MICROFABRICATION OF NOVEL X-RAY OPTICS II, 2004, 5539 : 138 - 147
  • [47] Determination of the emission spectrum of an X-ray tube of a wavelength-dispersive series X-ray fluorescence spectrometer
    Oskolok, K.V.
    Monogarova, O.V.
    Journal of Analytical Chemistry, 2008, 63 (12): : 1176 - 1181
  • [48] PRELIMINARY TESTING OF A PROTOTYPE PORTABLE X-RAY FLUORESCENCE SPECTROMETER.
    PATTERN, LOWELL L.
    ANDERSON, NEAL B.
    STEVENSON, JOHN J.
    1982,
  • [49] Analysis of art objects using a portable x-ray fluorescence spectrometer
    Moioli, P
    Seccaroni, C
    X-RAY SPECTROMETRY, 2000, 29 (01) : 48 - 52
  • [50] Analysis of gunshot residue using a handheld X-ray fluorescence spectrometer
    Tunney, Gene
    Pugh, Michael E.
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2013, 245