When one equals two: Chemometrics turns Mossbauer spectrometer into X-ray fluorescence one

被引:0
|
作者
Semenov, Valentin [1 ,2 ]
Grigoriev, Mikhail [1 ]
Kirsanov, Dmitry [1 ]
Panchuk, Vitaly [1 ,2 ]
机构
[1] St Petersburg State Univ, Inst Chem, St Petersburg, Russia
[2] RAS, Inst Analyt Instrumentat, St Petersburg, Russia
基金
俄罗斯科学基金会;
关键词
EDXRF; Mossbauer spectroscopy; Chemometrics; X-ray fluorescence; SPECTROSCOPY;
D O I
10.1016/j.sab.2024.106878
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
Here we explore the feasibility of using classical Mossbauer spectroscopy setup in scattering geometry to assess the elemental composition of samples using characteristic X-ray fluorescence. Even though, the scintillation detector of Mossbauer spectrometer yields rather low spectral resolution spectra, this can be effectively compensated using chemometric data processing. This hypothesis was first checked with simulated spectra of steel samples and afterwards was confirmed with real experiments. The results of Ti, Cr, Mn, Ni, Nb and Mo quantification in real steel samples obtained from Mossbauer spectrometer were compared with those obtained with commercial energy dispersive X-ray fluorescence (EDXRF) spectrometer. In case of Ti, Cr and Ni the accuracy attained with Mossbauer spectrometer was similar to that of an ordinary commercial EDXRF device.
引用
收藏
页数:6
相关论文
共 50 条
  • [32] An imaging X-ray fluorescence spectrometer for near earth objects
    Martin, AP
    Brunton, AN
    Fraser, GW
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 422 (1-3): : 567 - 571
  • [33] Basic studies on x-ray fluorescence analysis for active x-ray spectrometer on SELENE-2
    Kusano, Hiroki
    Hasebe, Nobuyuki
    Nagaoka, Hiroshi
    Kodama, Takuro
    Oyama, Yuki
    Tanaka, Reiko
    Amano, Yoshiharu
    Kim, Kyeong J.
    Matias Lopes, Jose A.
    HARD X-RAY, GAMMA-RAY, AND NEUTRON DETECTOR PHYSICS XV, 2013, 8852
  • [34] Development of Portable X-Ray Diffractometer Equipped with X-Ray Fluorescence Spectrometer and Its Application to Archaeology
    Yamashita, Daisuke
    Ishizaki, Atsushi
    Uda, Masayuki
    BUNSEKI KAGAKU, 2009, 58 (05) : 347 - 355
  • [35] An X-ray fluorescence spectrometer with a pyroelectric X-ray generator and a secondary target for the determination of Cr in steel
    Ida, H
    Kawai, J
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2005, 60 (01) : 89 - 93
  • [36] X-ray Scattering and Chemometrics as Tools to Assist in the Identifiication of Gunshot Residues by Wavelength Dispersive X-ray Fluorescence Spectrometry
    Madeira, Fernanda B.
    Saide, Victor G. P.
    Castro, Martha T. P. O.
    Barra, Cristina M.
    Rocha, Sheisi F. L. S.
    Almeida, Vanessa G. K.
    Canuto, Andre V. S.
    Shimamoto, Gustavo G.
    Tubino, Matthieu
    Rocha, Jose G., Jr.
    JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2020, 31 (12) : 2470 - 2478
  • [37] An X-ray refractive lens comprising two sections cut from a gramophone record for a portable total reflection X-ray fluorescence spectrometer
    Kunimura, Shinsuke
    Kawai, Jun
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2009, 64 (08) : 771 - 774
  • [38] When one plus one equals more than two - a novel stain for renal biopsies is a combination of two classical stains
    Brodsky, Sergey V.
    Albawardi, Alia
    Satoskar, Anjali A.
    Nadasdy, Gyongyi
    Nadasdy, Tibor
    HISTOLOGY AND HISTOPATHOLOGY, 2010, 25 (11) : 1379 - 1383
  • [39] Ultrafast one- and two-dimensional x-ray imaging by use of x-ray streak cameras with one- and two-dimensional image-sampling technique
    Shiraga, H
    Heya, M
    Fujioka, S
    Miyanaga, N
    Matsuoka, M
    Azechi, H
    Yamanaka, T
    24TH INTERNATIONAL CONGRESS ON HIGH-SPEED PHOTOGRAPHY AND PHOTONICS, 2001, 4183 : 339 - 350
  • [40] Combining X-ray and Three-Dimensional Scanning of Sawlogs - Comparison between One and Two X-ray Directions
    Skog, Johan
    Oja, Johan
    2009 PROCEEDINGS OF 6TH INTERNATIONAL SYMPOSIUM ON IMAGE AND SIGNAL PROCESSING AND ANALYSIS (ISPA 2009), 2009, : 353 - 358