Fabrication and Characterization of Piezoelectric PEO/SF/BaTiO3 Scaffolds for Cardiac Tissue Engineering

被引:4
|
作者
Khalil, Abdelrahman K. A. [1 ]
Fouad, Hassan [2 ]
Abdal-hay, Abdalla [3 ,4 ]
Abd El-salam, Nasser M. M. [2 ]
Khalil, Khalil Abdelrazek [5 ]
机构
[1] King Saud Univ, Coll Engn, Grad Mech Engn Dept, Riyadh 12372, Saudi Arabia
[2] King Saud Univ, Community Coll, Appl Med Sci Dept, Riyadh 12642, Saudi Arabia
[3] Univ Queensland, Sch Dent, Herston Campus, St Lucia, Qld 4072, Australia
[4] South Valley Univ, Fac Engn, Dept Mech Engn, Qena 83523, Egypt
[5] Univ Sharjah, Coll Engn, Dept Mech & Nucl Engn, POB 27272, Sharjah, U Arab Emirates
来源
JOURNAL OF COMPOSITES SCIENCE | 2023年 / 7卷 / 05期
关键词
cardiac tissue engineering; PEO; piezoelectric properties; barium titanate; HEART-FAILURE; SILK FIBROIN; MORTALITY; NANOFIBERS; STRATEGIES; MORBIDITY; PATHWAYS; THERAPY; DISEASE; MATRIX;
D O I
10.3390/jcs7050200
中图分类号
TB33 [复合材料];
学科分类号
摘要
The existence of an intrinsic electrical platform responsible for the formation and transmission of impulses is essential, especially in cardiac tissue. However, most cardiac tissue made from biodegradable polymeric materials lacks conductive characteristics; this delays regional conduction, potentially causing arrhythmias. This study proposes a conductive polyethylene oxide (PEO)/silk fibroin (SF)-based material conjugated with conductive nanoparticles as a cardiac patch to fix any infarcted heart part. A new composite of PEO/15 wt%SF/0.2 wt%BaTiO3 was prepared and characterized in vitro. The obtained patches were characterized by conventional Bragg-platinum-conductive action (XRD), FTIR spectroscopy, Raman spectra, and thermogravimetric analysis. A PiezoTester device was used to evaluate the piezoelectric properties. The produced samples of 500 mu m thickness were assessed in tapping mode. The applied load was selected to be as low as possible, and the frequencies were adjusted to simulate the heartbeats, ranging from 10 to 100 Hz. The results showed that a maximum of around 1100 mV was obtained at a load of 20 N. A maximum of about 80 mV was received at an applied force of 1 N and a frequency of 100 Hz, which matches the electricity generated by the human heart. The cytotoxicity effect of prepared films was tested against AC16 cells using microculture tetrazolium assay (MTT). The pristine PEO cell viability either was not affected by adding SF or slightly decreased. However, the cell viability dramatically increased by adding BaTiO3 to the PEO/SF composites. The confocal microscope images proved that the cells showed a spread morphology. The cells adhered to the PEO membranes and demonstrated a well-spread morphology. Overall, our study suggests that the PEO/SF/BaTiO3 composite can be a promising cardiac patch material for repairing infarcted heart tissue, as it is conductive, has good mechanical properties, and is biocompatible.
引用
收藏
页数:14
相关论文
共 50 条
  • [41] Artificial Scaffolds in Cardiac Tissue Engineering
    Roacho-Perez, Jorge A.
    Garza-Trevino, Elsa N.
    Moncada-Saucedo, Nidia K.
    Carriquiry-Chequer, Pablo A.
    Valencia-Gomez, Laura E.
    Matthews, Elizabeth Renee
    Gomez-Flores, Victor
    Simental-Mendia, Mario
    Delgado-Gonzalez, Paulina
    Delgado-Gallegos, Juan Luis
    Padilla-Rivas, Gerardo R.
    Islas, Jose Francisco
    LIFE-BASEL, 2022, 12 (08):
  • [42] Fabrication of BaTiO3 microstructures by hydrothermal growth
    Hoffmann, T
    Doll, T
    Fuenzalida, VM
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1997, 144 (11) : L292 - L293
  • [43] Scaffolds for tissue engineering of cardiac valves
    Jana, S.
    Tefft, B. J.
    Spoon, D. B.
    Simari, R. D.
    ACTA BIOMATERIALIA, 2014, 10 (07) : 2877 - 2893
  • [44] Fabrication and Characterization of NiO-doped BaTiO3 for Multilayer Ceramic Capacitor
    Hossain, T. M. S. A.
    Matin, M. A.
    Hakim, M. A.
    Islam, M. F.
    2018 10TH INTERNATIONAL CONFERENCE ON ELECTRICAL AND COMPUTER ENGINEERING (ICECE), 2018, : 77 - 80
  • [45] Electrostrictive and piezoelectric effect in BaTiO3 and PbZrO3
    Wieczorek, K.
    Ziebinska, A.
    Ujma, Z.
    Szot, K.
    Gorny, M.
    Franke, I.
    Koperski, J.
    Soszynski, A.
    Roleder, K.
    FERROELECTRICS, 2006, 336 : 61 - 67
  • [46] 3D fabrication methods for producing tissue engineering scaffolds
    Gadegaard, N.
    Seunarine, K.
    Meredith, D. O.
    Khan, M. A.
    Tormen, M.
    Wilkinson, C. D. W.
    Riehle, M. O.
    MICROPROCESSES AND NANOTECHNOLOGY 2007, DIGEST OF PAPERS, 2007, : 410 - +
  • [47] Design, fabrication, and characterization of 3D-printed ABS and PLA scaffolds potentially for tissue engineering
    Rahatuzzaman, Md
    Mahmud, Minar
    Rahman, Sazedur
    Hoque, Md Enamul
    RESULTS IN ENGINEERING, 2024, 21 (21)
  • [48] Fabrication and Characterization of Waterborne Biodegradable Polyurethanes 3-Dimensional Porous Scaffolds for Vascular Tissue Engineering
    Jiang, Xia
    Yu, Feilong
    Wang, Zhigao
    Li, Jiehua
    Tan, Hong
    Ding, Mingming
    Fu, Qiang
    JOURNAL OF BIOMATERIALS SCIENCE-POLYMER EDITION, 2010, 21 (12) : 1637 - 1652
  • [49] Fabrication and characterization of hybrid PCL/PEG 3D scaffolds for potential tissue engineering applications
    Hoque, M. Enamul
    Meng, Terrence Teh Hooi
    Chuan, Y. Leng
    Chowdhury, Moniruddin
    Prasad, R. G. S. V.
    MATERIALS LETTERS, 2014, 131 : 255 - 258
  • [50] Fabrication of Bioceramic Bone Scaffolds for Tissue Engineering
    Fwu-Hsing Liu
    Journal of Materials Engineering and Performance, 2014, 23 : 3762 - 3769