Portable biosensor combining CRISPR/Cas12a and loop-mediated isothermal amplification for antibiotic resistance gene ermB in wastewater

被引:21
|
作者
Mao, Kang [1 ]
Zhang, Hua [1 ]
Ran, Fang [1 ]
Cao, Haorui [1 ]
Feng, Rida [1 ]
Du, Wei [2 ]
Li, Xiqing [3 ]
Yang, Zhugen [4 ]
机构
[1] Chinese Acad Sci, Inst Geochem, State Key Lab Environm Geochem, Guiyang 550081, Peoples R China
[2] Kunming Univ Sci & Technol, Fac Environm Sci & Engn, Kunming 650500, Peoples R China
[3] Peking Univ, Coll Urban & Environm Sci, Lab Earth Surface Proc, Beijing 100871, Peoples R China
[4] Cranfield Univ, Sch Water Energy & Environm, Cranfield MK43 0AL, England
基金
中国国家自然科学基金;
关键词
Antibiotic resistance gene; CRISPR/Cas12a; Loop-mediated isothermal amplification; Biosensor; Wastewater; NUCLEIC-ACID DETECTION; DIAGNOSTICS; SARS-COV-2;
D O I
10.1016/j.jhazmat.2023.132793
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Wastewater is among the main sources of antibiotic resistance genes (ARGs) in the environment, but effective methods to quickly assess ARGs on-site in wastewater are lacking. Here, using the typical ARG ermB as the target, we report a portable biosensor combining CRISPR/Cas12a and loop-mediated isothermal amplification (LAMP) for the detection of ARGs. Six primers of LAMP and the crRNA of CRISPR/Cas12a were first designed to be preamplification with LAMP and lead Cas12a to recognize the ermB via base pairing. Due to the trans-cleavage activity of CRISPR/Cas12a after amplicon recognition, ssDNA probes modified with reporter molecules were used to implement a visual assay with lateral flow test strips and fluorescence. After a simple nucleic acid extraction with magnetic beads, the constructed biosensor possesses excellent sensitivity and selectivity as low as 2.75 x 103 copies/mu L using fluorescence and later flow strips in wastewater. We further evaluated the community-wide prevalence of ermB in wastewater influent and found high mass loads of ermB during different months. This user-friendly and low-cost biosensor is applicable for rapid on-site ARG detection, providing a
引用
收藏
页数:10
相关论文
共 50 条
  • [21] Development of Two Loop-Mediated Isothermal Amplification Assays for Rapid Detection of ermB and mefA Genes in Streptococcus suis
    Li, LuLu
    Ren, JinRui
    Zhang, Qing
    Luo, YanBo
    Zhang, Yin
    Qi, Jing
    Zhao, XiaoNan
    Hu, Ming
    Liu, YuQing
    FOODBORNE PATHOGENS AND DISEASE, 2022, 19 (12) : 817 - 822
  • [22] Application of loop-mediated isothermal amplification to detect the aph gene in staphylococcus
    Li, Xiu-Mei
    Liang, Zhi-Xuan
    Li, Ying
    Li, Xia
    Huang, Jin-Hai
    Wang, Hong-Jun
    Modern Food Science and Technology, 2015, 31 (07) : 326 - 330
  • [23] Development of a reverse transcription loop-mediated isothermal amplification based clustered regularly interspaced short palindromic repeats Cas12a assay for duck Tembusu virus
    Ding, Yangbao
    Huang, Zhanhong
    Li, Xinbo
    Tang, Mei
    Li, Weiqiang
    Feng, Siyu
    Zhao, Luxiang
    Zhang, Junsheng
    Yuan, Shichao
    Shan, Fen
    Jiao, Peirong
    FRONTIERS IN MICROBIOLOGY, 2023, 14
  • [24] CRISPR/Cas12a-Assisted Ligation-Initiated Loop-Mediated Isothermal Amplification (CAL-LAMP) for Highly Specific Detection of microRNAs
    Zhang, Mai
    Wang, Honghong
    Wang, Hui
    Wang, Fangfang
    Li, Zhengping
    ANALYTICAL CHEMISTRY, 2021, 93 (22) : 7942 - 7948
  • [25] Detection of Four Porcine Enteric Coronaviruses Using CRISPR-Cas12a Combined with Multiplex Reverse Transcriptase Loop-Mediated Isothermal Amplification Assay
    Liu, Jiajia
    Tao, Dagang
    Chen, Xinquan
    Shen, Linyuan
    Zhu, Li
    Xu, Bingrong
    Liu, Hailong
    Zhao, Shuhong
    Li, Xinyun
    Liu, Xiangdong
    Xie, Shengsong
    Niu, Lili
    VIRUSES-BASEL, 2022, 14 (04):
  • [26] ISFET Biosensor with Loop-Mediated Isothermal Amplification for Electronic Rapid Detection of Mycoplasma Pneumoniae
    Zou, Jie
    Hu, Jie
    Shen, Yan
    Zhang, Limei
    Bai, Weiyi
    Wang, Lei
    Li, Jianlong
    Yan, Lin
    Zhang, Zhifeng
    Bai, Hao
    Hu, Wenchuang
    SENSORS, 2025, 25 (05)
  • [27] Design and Application of a Portable Multi-Channel Turbidimeter by Loop-Mediated Isothermal Amplification
    Yang, Tong
    Wu, Chao
    Li, Zhiyang
    Chen, Yuxin
    Chen, Hui
    Gao, Hansong
    Liu, Mei
    He, Nongyue
    Liu, Hongna
    Liu, Bin
    Chen, Zhu
    Elingarami, Sauli
    Shah, Muhammad Ali
    NANOSCIENCE AND NANOTECHNOLOGY LETTERS, 2017, 9 (12) : 1926 - 1933
  • [28] Portable loop-mediated isothermal amplification device with spectrometric detection for rapid pathogen identification
    Pan, Chun Yu
    Kijamnajsuk, Puchong
    Chen, Jyh Jian
    ANALYTICAL BIOCHEMISTRY, 2024, 694
  • [29] CUT-LAMP: Contamination-Free Loop-Mediated Isothermal Amplification Based on the CRISPR/Cas9 Cleavage
    Bao, Yijuan
    Jiang, Yongzhong
    Xiong, Erhu
    Tian, Tian
    Zhang, Zhenzhen
    Lv, Jing
    Li, Yang
    Zhou, Xiaoming
    ACS SENSORS, 2020, 5 (04) : 1082 - 1091
  • [30] Amplification-Based CRISPR/Cas12a Biosensor Targeting the COX1 Gene for Specific Detection of Porcine DNA
    Janudin, Arifah A. S.
    Kurup, Chitra P.
    Chee, Lim Ya
    Mohd-Naim, Noor F.
    Ahmed, Minhaz U.
    ACS OMEGA, 2023, 8 (41): : 38212 - 38219