A Tool to Enable Intraoperative Insertion Force Measurements for Cochlear Implant Surgery

被引:4
|
作者
Boettcher-Rebmann, Georg [1 ,2 ]
Schell, Viktor [1 ,2 ]
Budde, Leon [3 ]
Zuniga, M. Geraldine [1 ,2 ]
Baier, Claas [4 ]
Lenarz, Thomas [1 ,2 ]
Rau, Thomas S. S. [1 ,2 ]
机构
[1] Hannover Med Sch, Dept Otorhinolaryngol Head & Neck Surg, D-30625 Hannover, Germany
[2] Hannover Med Sch, Cluster Excellence EXC 2177 1 Hearing4all, D-30625 Hannover, Germany
[3] Leibniz Univ Hannover, Inst Mechatron Syst, Hannover, Germany
[4] Hannover Med Sch, Inst Med Microbiol & Hosp Epidemiol, Hannover, Germany
关键词
Force measurement; Surgery; Biomedical measurement; Force sensors; Manuals; Ear; Sensors; Cochlear implant; gravity-independent force measurement; insertion forces; intraoperative insertion force measurement; manual insertion tool; AUTOMATED INSERTION;
D O I
10.1109/TBME.2022.3224528
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective: Residual hearing preservation during cochlear implant (CI) surgery is closely linked to the magnitude of intracochlear forces acting during the insertion process. So far, these forces have only been measured in vitro. Therefore, the range of insertion forces and the magnitude of damage-inducing thresholds in the human cochlea in vivo remain unknown. We aimed to develop a method to intraoperatively measure insertion forces without negatively affecting the established surgical workflow. Initial experiments showed that this requires the compensation of orientation-dependent gravitational forces. Methods: We devised design requirements for a force-sensing manual insertion tool. Experienced CI surgeons evaluated the proposed design for surgical safety and handling quality. Measured forces from automated and manual insertions into an artificial cochlea model were evaluated against data from a static external force sensor representing the gold standard. Results: The finalized manual insertion tool uses an embedded force sensor and inertial measurement unit to measure insertion forces. The evaluation of the proposed design shows the feasibility of orientation-independent insertion force measurements. Recorded forces correspond well to externally recorded reference forces after reliable removal of gravitational disturbances. CI surgeons successfully used the tool to insert electrode arrays into human cadaver cochleae. Conclusion: The presented positive evaluation poses the first step towards intraoperative use of the proposed tool. Further in vitro experiments with human specimens will ensure reliable in vivo measurements. Significance: Intraoperative insertion force measurements enabled by this tool will provide insights on the relationship between forces and hearing outcomes in cochlear implant surgery.
引用
收藏
页码:1643 / 1650
页数:8
相关论文
共 50 条
  • [41] Comparison of Skull Radiograph and Computed Tomography Measurements of Cochlear Implant Insertion Angles
    Gallant, Sara
    Friedmann, David R.
    Hagiwara, Mari
    Roland, J. Thomas, Jr.
    Svirsky, Mario A.
    Jethanamest, Daniel
    OTOLOGY & NEUROTOLOGY, 2019, 40 (03) : E298 - E303
  • [42] Cochlear Implant Surgery
    Mowry, Sarah E.
    Woodson, Erika
    JAMA OTOLARYNGOLOGY-HEAD & NECK SURGERY, 2020, 146 (01) : 92 - 92
  • [43] New window for cochlear implant insertion
    Colletti, V
    Fiorino, FG
    ACTA OTO-LARYNGOLOGICA, 1999, 119 (02) : 214 - 218
  • [44] Optimal Cochlear Implant Insertion Vectors
    Meshik, Xenia
    Holden, Timothy A.
    Chole, Richard A.
    Hullar, Timothy E.
    OTOLOGY & NEUROTOLOGY, 2010, 31 (01) : 58 - 63
  • [45] Remote Intraoperative Neural Response Telemetry: Technique and Results in Cochlear Implant Surgery
    Kouhi, Ali
    Swanson, Austin
    Fitzgerald, Matthew B.
    Blevins, Nikolas H.
    OTOLOGY & NEUROTOLOGY, 2022, 43 (06) : 638 - 642
  • [46] First clinical implementation of insertion force measurement in cochlear implantation surgery
    Rau, Thomas S.
    Boettcher-Rebmann, Georg
    Schell, Viktor
    Cramer, Jakob
    Artukarslan, Eralp
    Baier, Claas
    Lenarz, Thomas
    Salcher, Rolf
    FRONTIERS IN NEUROLOGY, 2024, 15
  • [47] Does pediatric cochlear implant insertion technique affect intraoperative neural response telemetry thresholds?
    Poley, Marian
    Overmyer, Emma
    Craun, Patricia
    Holcomb, Meredith
    Reilly, Brian
    White, David
    Preciado, Diego
    INTERNATIONAL JOURNAL OF PEDIATRIC OTORHINOLARYNGOLOGY, 2015, 79 (09) : 1404 - 1407
  • [48] Deep round window insertion versus standard approach in cochlear implant surgery
    Nordfalk, Karl Fredrik
    Rasmussen, Kjell
    Bunne, Marie
    Jablonski, Greg Eigner
    EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 2016, 273 (01) : 43 - 50
  • [49] Deep round window insertion versus standard approach in cochlear implant surgery
    Karl Fredrik Nordfalk
    Kjell Rasmussen
    Marie Bunne
    Greg Eigner Jablonski
    European Archives of Oto-Rhino-Laryngology, 2016, 273 : 43 - 50
  • [50] Factors Associated with Incomplete Insertion of Electrodes in Cochlear Implant Surgery: A Histopathologic Study
    Lee, Joonhan
    Nadol, Joseph B., Jr.
    Eddington, Donald K.
    AUDIOLOGY AND NEURO-OTOLOGY, 2011, 16 (02) : 69 - 81