Prediction of Hemodynamic-Related Hemolysis in Carotid Stenosis and Aiding in Treatment Planning and Risk Stratification Using Computational Fluid Dynamics

被引:2
|
作者
Jedrzejczak, Krystian [1 ]
Orciuch, Wojciech [1 ]
Wojtas, Krzysztof [1 ]
Kozlowski, Michal [2 ]
Piasecki, Piotr [3 ]
Narloch, Jerzy [3 ]
Wierzbicki, Marek [3 ]
Makowski, Lukasz [1 ]
机构
[1] Warsaw Univ Technol, Fac Chem & Proc Engn, Warynskiego 1, PL-00645 Warsaw, Poland
[2] Med Univ Silesia, Dept Cardiol & Struct Heart Dis, Ziolowa 47, PL-40635 Katowice, Poland
[3] Natl Res Inst, Mil Inst Med, Intervent Radiol Dept, Szaserow 128, PL-04141 Warsaw, Poland
关键词
arteriosclerosis; hemolysis; blood; CFD; coronary artery; carotid artery; percutaneous coronary intervention; hemoglobin; NONHOMOGENEOUS CONSTITUTIVE MODEL; OPTICAL COHERENCE TOMOGRAPHY; NEWTONIAN BLOOD-FLOW; NANOPARTICLE CLUSTERS; MECHANICAL HEMOLYSIS; NUMERICAL-SIMULATION; COMPUTED-TOMOGRAPHY; MAGNETIC-RESONANCE; HEART-VALVE; IN-VIVO;
D O I
10.3390/biomedicines12010037
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Atherosclerosis affects human health in many ways, leading to disability or premature death due to ischemic heart disease, stroke, or limb ischemia. Poststenotic blood flow disruption may also play an essential role in artery wall impairment linked with hemolysis related to shear stress. The maximum shear stress in the atherosclerotic plaque area is the main parameter determining hemolysis risk. In our work, a 3D internal carotid artery model was built from CT scans performed on patients qualified for percutaneous angioplasty due to its symptomatic stenosis. The obtained stenosis geometries were used to conduct a series of computer simulations to identify critical parameters corresponding to the increase in shear stress in the arteries. Stenosis shape parameters responsible for the increase in shear stress were determined. The effect of changes in the carotid artery size, length, and degree of narrowing on the change in maximum shear stress was demonstrated. Then, a correlation for the quick initial diagnosis of atherosclerotic stenoses regarding the risk of hemolysis was developed. The developed relationship for rapid hemolysis risk assessment uses information from typical non-invasive tests for treated patients. Practical guidelines have been developed regarding which stenosis shape parameters pose a risk of hemolysis, which may be adapted in medical practice.
引用
收藏
页数:20
相关论文
共 25 条
  • [11] Hemodynamic Changes in the Carotid Artery after Infusion of Normal Saline Using Computational Fluid Dynamics
    Lee, Ui Yun
    Kim, Chul In
    Chung, Gyung Ho
    Jung, Jinmu
    Kwak, Hyo Sung
    DIAGNOSTICS, 2020, 10 (07)
  • [12] Hemodynamic analysis of cerebral aneurysm and stenosed carotid bifurcation using computational fluid dynamics technique
    Qian, Yi
    Harada, Tetsuji
    Fukui, Koichi
    Urnezu, Mitsuo
    Takao, Hiroyuki
    Murayama, Yuichi
    Life System Modeling and Simulation, Proceedings, 2007, 4689 : 292 - 299
  • [13] USING COMPUTATIONAL FLUID DYNAMICS TO DESIGN AND OPTIMIZE A NOVEL ENDOVASCULAR PROCEDURE FOR CAROTID STENOSIS REPAIR
    Yeh, Victoria
    Figueroa, C. Alberto
    Les, Andrea
    Ho, Jacqueline P.
    Dalman, Ronald
    Taylor, Charles A.
    PROCEEDINGS OF THE ASME SUMMER BIOENGINEERING CONFERENCE 2008, PTS A AND B, 2009, : 593 - 594
  • [14] Computational simulation of carotid stenosis and flow dynamics based on patient ultrasound data - A new tool for risk assessment and surgical planning
    Sousa, Luisa C.
    Castro, Catarina F.
    Antonio, Carlos C.
    Sousa, Fernando
    Santos, Rosa
    Castro, Pedro
    Azevedo, Elsa
    ADVANCES IN MEDICAL SCIENCES, 2016, 61 (01): : 32 - 39
  • [15] Assessing the Risk of Intracranial Aneurysm Rupture Using Morphological and Hemodynamic Biomarkers Evaluated from Magnetic Resonance Fluid Dynamics and Computational Fluid Dynamics
    Perera, Roshani
    Isoda, Haruo
    Ishiguro, Kenta
    Mizuno, Takashi
    Takehara, Yasuo
    Terada, Masaki
    Tanoi, Chiharu
    Naito, Takehiro
    Sakahara, Harumi
    Hiramatsu, Hisaya
    Namba, Hiroki
    Izumi, Takashi
    Wakabayashi, Toshihiko
    Kosugi, Takafumi
    Onishi, Yuki
    Alley, Marcus
    Komori, Yoshiaki
    Ikeda, Mitsuru
    Naganawa, Shinji
    MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2020, 19 (04) : 333 - 344
  • [16] ASSESSMENT OF HEMODYNAMIC PARAMETERS DISTRIBUTION IN NORMAL CAROTID ARTERY BY USING COMPUTATIONAL FLUID DYNAMICS BASED ON CE-MRA DATA
    Li, Xiao
    Sun, Beibei
    Suo, Shiteng
    Ge, Xiaoqian
    Zhao, Huilin
    Sun, Yi
    Xu, Jianrong
    Gao, Bulang
    Liu, Xiaosheng
    BIOSCIENCE JOURNAL, 2018, 34 (02): : 1134 - 1139
  • [17] The Hemodynamic Effect of Enhanced External Counterpulsation Treatment on Atherosclerotic Plaque in the Carotid Artery: A Framework of Patient-Specific Computational Fluid Dynamics Analysis
    Du, Jianhang
    Wu, Guangyao
    Wu, Bokai
    Liu, Chang
    Mai, Zhouming
    Liu, Yumeng
    Wang, Yawei
    Zhang, Pandeng
    Wu, Guifu
    Liu, Jia
    CARDIOLOGY RESEARCH AND PRACTICE, 2020, 2020
  • [18] Virtual treatment planning in three patients with univentricular physiology using computational fluid dynamics-Pitfalls and strategies
    Schafstedde, Marie
    Yevtushenko, Pavlo
    Nordmeyer, Sarah
    Kramer, Peter
    Schleiger, Anastasia
    Solowjowa, Natalia
    Berger, Felix
    Photiadis, Joachim
    Mykychak, Yaroslav
    Cho, Mi-Young
    Ovroutski, Stanislav
    Kuehne, Titus
    Bruening, Jan
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2022, 9
  • [19] Virtual Stent Grafting in Personalized Surgical Planning for Treatment of Aortic Aneurysms Using Image-Based Computational Fluid Dynamics
    Xiong, Guanglei
    Taylor, Charles A.
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2010, PT III, 2010, 6363 : 375 - +
  • [20] Hemodynamic analysis of renal artery stenosis using computational fluid dynamics technology based on unenhanced steady-state free precession magnetic resonance angiography: preliminary results
    Zhang, Weisheng
    Qian, Yi
    Lin, Jiang
    Lv, Peng
    Karunanithi, Kaavya
    Zeng, Mengsu
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2014, 30 (02): : 367 - 375