The Hemodynamic Effect of Enhanced External Counterpulsation Treatment on Atherosclerotic Plaque in the Carotid Artery: A Framework of Patient-Specific Computational Fluid Dynamics Analysis

被引:4
|
作者
Du, Jianhang [1 ,2 ,3 ]
Wu, Guangyao [4 ]
Wu, Bokai [5 ]
Liu, Chang [5 ]
Mai, Zhouming [1 ,2 ]
Liu, Yumeng [5 ]
Wang, Yawei [6 ]
Zhang, Pandeng [5 ]
Wu, Guifu [1 ,2 ,3 ]
Liu, Jia [5 ,7 ]
机构
[1] Sun Yat Sen Univ, Affiliated Hosp 8, Dept Cardiol, Shenzhen 518033, Peoples R China
[2] Sun Yat Sen Univ, Guangdong Innovat Engn & Technol Res Ctr Assisted, Shenzhen 518033, Peoples R China
[3] Sun Yat Sen Univ, NHC Key Lab Assisted Circulat, Guangzhou 510080, Peoples R China
[4] Shenzhen Univ Gen Hosp, Dept Radiol, Shenzhen 518055, Peoples R China
[5] Chinese Acad Sci, Shenzhen Inst Adv Technol, Lab Engn & Sci Comp, Shenzhen 518055, Peoples R China
[6] Beihang Univ, Sch Biol Sci & Med Engn, Beijing 100083, Peoples R China
[7] Shenzhen Key Lab Exascale Engn & Sci Comp, Shenzhen, Peoples R China
基金
中国国家自然科学基金;
关键词
ISCHEMIC-STROKE; FLOW; ANGINA; PROGRESSION; GUIDELINES; MANAGEMENT; PRESSURE; LOCATION;
D O I
10.1155/2020/5903790
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Long-term enhanced external counterpulsation (EECP) therapy has been recommended for antiatherogenesis in recent clinical observations and trials. However, the precise mechanism underlying the benefits has not been fully clarified. To quantify the effect of EECP intervention on arterial hemodynamic environment, a framework of numerical assessment was introduced using a parallel computing algorithm. A 3D endothelial surface of the carotid artery with mild atherosclerotic plaque was constructed from images of magnetic resonance angiography (MRA). Physiologic boundary conditions were derived from images of the ultrasound flow velocity spectrum measured at the common carotid artery and before and during EECP intervention. Hemodynamic factors relating to wall shear stress (WSS) and its spatial and temporal fluctuations were calculated and analyzed, which included AWSS, OSI, and AWSSG. Measuring and computational results showed that diastole blood pressure, perfusion, and WSS level in carotid bifurcation were significantly increased during EECP intervention. Mean AWSS level throughout the model increased by 16.9%, while OSI level did not show a significant change during EECP. We thus suggested that long-term EECP treatment might inhibit the initiation and development of atherosclerotic plaque via improving the hemodynamic environment in the carotid artery. Meanwhile, EECP performance induced a 19.6% increase in AWSSG level, and whether it would influence the endothelial functions may need a further study. Moreover, the numerical method proposed in this study was expected to be useful for the instant assessment of clinical application of EECP .
引用
下载
收藏
页数:12
相关论文
共 50 条
  • [1] Spatiotemporal transfer of nitric oxide in patient-specific atherosclerotic carotid artery bifurcations with MRI and computational fluid dynamics modeling
    Qian, Shan
    Ma, Tianxiang
    Zhang, Nan
    Liu, Xiao
    Zhao, Ping
    Li, Xiaoyin
    Chen, Duo
    Hu, Liang
    Chang, Lingqian
    Xu, Lei
    Deng, Xiaoyan
    Fan, Yubo
    COMPUTERS IN BIOLOGY AND MEDICINE, 2020, 125
  • [2] Analysis of Patient-Specific Carotid Bifurcation Models Using Computational Fluid Dynamics
    Tu, Jiyuan
    Wong, Kelvin K. L.
    Cheung, Sherman C. P.
    Beare, Richard
    Phan, Thanh
    JOURNAL OF MEDICAL IMAGING AND HEALTH INFORMATICS, 2011, 1 (02) : 116 - 125
  • [3] A real-time patient-specific treatment strategy for enhanced external counterpulsation
    Li, Bao
    Liu, Youjun
    Li, Guangfei
    Zhang, Zhe
    Feng, Yue
    Mao, Boyan
    INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING, 2024, 40 (04)
  • [4] Computational Fluid Dynamics Analysis of Carotid-Ophthalmic Aneurysms with Concomitant Ophthalmic Artery Infundibulum in a Patient-Specific Model
    Ba, Dechun
    Zhu, Zhipeng
    Yue, Xiangji
    Xu, Ping
    Yan, Pengfei
    Xiao, Dongdong
    WORLD NEUROSURGERY, 2019, 125 : E1023 - E1033
  • [5] Effect of Inlet Velocity Profiles on Patient-Specific Computational Fluid Dynamics Simulations of the Carotid Bifurcation
    Campbell, Ian C.
    Ries, Jared
    Dhawan, Saurabh S.
    Quyyumi, Arshed A.
    Taylor, W. Robert
    Oshinski, John N.
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2012, 134 (05):
  • [6] Combined imaging, computational and histological analysis of a ruptured carotid plaque: A patient-specific analysis
    Soloperto G.
    Keenan N.G.
    Sheppard M.N.
    Ohayon J.
    Wood N.B.
    Pennell D.J.
    Mohiaddin R.H.
    Xu X.Y.
    Artery Research, 2010, 4 (2) : 59 - 65
  • [7] Analysis of haemodynamic disturbance in the atherosclerotic carotid artery using computational fluid dynamics
    Daniel Birchall
    Azfar Zaman
    Jacob Hacker
    Gavin Davies
    David Mendelow
    European Radiology, 2006, 16 : 1074 - 1083
  • [8] Analysis of haemodynamic disturbance in the atherosclerotic carotid artery using computational fluid dynamics
    Birchall, D
    Zaman, A
    Hacker, J
    Davies, G
    Mendelow, D
    EUROPEAN RADIOLOGY, 2006, 16 (05) : 1074 - 1083
  • [9] Preliminary study of hemodynamic distribution in patient-specific stenotic carotid bifurcation by image-based computational fluid dynamics
    Xue, Y. -J.
    Gao, P. -Y.
    Duan, Q.
    Lin, Y.
    Dai, C. -B.
    ACTA RADIOLOGICA, 2008, 49 (05) : 558 - 565
  • [10] A comparison of estimation methods for computational fluid dynamics outflow boundary conditions using patient-specific carotid artery
    Lee, Chang-Joon
    Uemiya, Nahoko
    Ishihara, Shoichiro
    Zhang, Yu
    Qian, Yi
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2013, 227 (H6) : 663 - 671