Skin erosion following deep brain stimulator implantation: A case report

被引:0
|
作者
Xiao, Zhiyuan [1 ]
Gong, Le [1 ]
Chang, Guojing [2 ]
Long, Xiao [2 ]
Pan, Zhouxian [3 ]
Guo, Xiaopeng [1 ]
Wang, Yu [1 ]
Zhang, Yi [1 ]
Ma, Wenbin [1 ]
Guo, Yi [1 ,4 ]
机构
[1] Chinese Acad Med Sci & Peking Union Med Coll, Peking Union Med Coll Hosp, Dept Neurosurg, Beijing, Peoples R China
[2] Chinese Acad Med Sci & Peking Union Med Coll, Peking Union Med Coll Hosp, Dept Plast & Aesthet Surg, Beijing, Peoples R China
[3] Chinese Acad Med Sci & Peking Union Med Coll, Peking Union Med Coll Hosp, Dept Allergy, Beijing, Peoples R China
[4] Peking Union Med Coll Hosp East, 1 Shuaifuyuan Wangfujing Dongcheng Dist, Beijing, Peoples R China
关键词
Deep brain stimulation; Parkinson's disease; Skin erosion; HARDWARE-RELATED COMPLICATIONS; SCALP EROSION; ALLERGIC REACTION; MANAGEMENT;
D O I
10.1016/j.inat.2023.101891
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Deep brain stimulation (DBS) is an established safe neurosurgical symptomatic therapy for Parkinson's disease (PD) in whom medical treatment fails to provide adequate symptom control. Skin-related complications, particularly skin erosion, may lead to exposure of the DBS device, compromising the effectiveness of the DBS device. We presented a patient who suffered from skin erosion over bilateral burr hole site. A Multidisciplinary Team (MDT) approach was used to provide staged surgical treatment for scalp reconstruction. Without the removal of the DBS system. No alteration of DBS system efficacy was observed and the bilateral wounds healed well during the follow-up period.
引用
收藏
页数:5
相关论文
共 50 条
  • [21] Spinal lumbar multimodal neurophysiological monitoring in a patient with deep brain Stimulator: A case report
    San-juan, Daniel
    Diaz-Martinez, Rafael
    Alcocer-Barradas, Victor
    Ortega-Porcayo, Luis Alberto
    Osuna-Zazueta, Marcela Amparo
    Tejada-Pineda, Maria Fernanda
    CLINICAL NEUROPHYSIOLOGY PRACTICE, 2024, 9 : 261 - 265
  • [22] Transcranial Motor Evoked Potential Monitoring in a Patient With a Deep Brain Stimulator: A Case Report
    Srisooksai, Gevalin
    Mohamed, Basma A.
    Martin, Pamela A.
    Blakemore, Laurel C.
    Seubert, Christoph N.
    JOURNAL OF CLINICAL NEUROPHYSIOLOGY, 2021, 38 (01) : E1 - E4
  • [23] Intracranial Hemorrhage Following Removal of Deep Brain Stimulator Electrode
    Liu, James K.
    Soliman, Hesham
    Deogaonkar, Milind
    Machado, Andre
    Rezai, Ali
    JOURNAL OF NEUROSURGERY, 2009, 111 (02) : 418 - 419
  • [24] Surgical Management of Deep Brain Stimulator Scalp Erosion without Hardware Removal
    Staudt, Michael D.
    Pourtaheri, Navid
    Lakin, Gregory E.
    Soltanian, Hooman T.
    Miller, Jonathan P.
    STEREOTACTIC AND FUNCTIONAL NEUROSURGERY, 2017, 95 (06) : 385 - 391
  • [25] A Report of Paraparesis Following Spinal Cord Stimulator Trial, Implantation and Revision
    Smith, Clark C.
    Lin, John L.
    Shokat, Max
    Dosanjh, Sonny S.
    Casthely, Dionne
    PAIN PHYSICIAN, 2010, 13 (04) : 357 - 363
  • [26] Erosion Management after TVT Implantation - A Case Report
    Juse, D.
    Anthuber, C.
    GEBURTSHILFE UND FRAUENHEILKUNDE, 2024, 84 (06) : E47 - E47
  • [27] Vacuum-Assisted Closure with Temporalis Muscle Reconstruction for Recurrent Scalp Erosion Following Deep Brain Stimulation: A Case Report
    Oh, Byeong Ho
    Park, Yoon Young
    Park, Ji Kang
    Park, Young Seok
    JOURNAL OF PARKINSONS DISEASE, 2021, 11 (03) : 1465 - 1469
  • [28] Pedicled Omental Transposition for Recurrent Skin Erosion Following Deep Brain Stimulation Without Hardware Removal
    Guan, Haonan
    Pan, Yixin
    Huang, Peng
    Tang, Jiajun
    Sun, Bomin
    Lu, Shuliang
    INDIAN JOURNAL OF SURGERY, 2023, 85 (01) : 143 - 148
  • [29] Pedicled Omental Transposition for Recurrent Skin Erosion Following Deep Brain Stimulation Without Hardware Removal
    Haonan Guan
    Yixin Pan
    Peng Huang
    Jiajun Tang
    Bomin Sun
    Shuliang Lu
    Indian Journal of Surgery, 2023, 85 : 143 - 148
  • [30] Infection following deep brain stimulator implantation performed in the conventional versus magnetic resonance imaging-equipped operating room
    Gorgulho, Alessandra
    Juillard, Catherine
    Uslan, Daniel Z.
    Tajik, Katayoun
    Aurasteh, Poorang
    Behnke, Eric
    Pegues, David
    De Salles, Antonio A. F.
    JOURNAL OF NEUROSURGERY, 2009, 110 (02) : 239 - 246