共 22 条
Infection following deep brain stimulator implantation performed in the conventional versus magnetic resonance imaging-equipped operating room
被引:32
|作者:
Gorgulho, Alessandra
[1
]
Juillard, Catherine
[1
]
Uslan, Daniel Z.
[2
]
Tajik, Katayoun
[1
]
Aurasteh, Poorang
[1
]
Behnke, Eric
[1
]
Pegues, David
[2
]
De Salles, Antonio A. F.
[1
]
机构:
[1] Univ Calif Los Angeles, Dept Neurosurg, Los Angeles, CA 90095 USA
[2] Univ Calif Los Angeles, David Geffen Sch Med, Dept Med, Div Infect Dis, Los Angeles, CA 90095 USA
关键词:
conventional operating room;
deep brain stimulation;
implantation;
infection;
magnetic resonance imaging-equipped operating room;
risk factor;
HARDWARE-RELATED COMPLICATIONS;
FUNCTIONAL NEUROSURGERY;
MRI ENVIRONMENT;
SURGERY;
D O I:
10.3171/2008.6.17603
中图分类号:
R74 [神经病学与精神病学];
学科分类号:
摘要:
Object. Risk factors for deep brain stimulator (DBS) infection are poorly defined. Because DBS implants are not frequently performed in the MR imaging-equipped operating room (OR), no specific data about infection of DBS implants performed in the MR imaging environment are available in the literature. In this Study the authors focus on the incidence of infection in patients undergoing surgery in the conventional versus MR imaging-equipped OR. Methods. To identify cases of DBS-associated infection. the authors performed a retrospective cohort study with nested case-control analysis of all patients undergoing DBS implantation at the University of California Los Angeles Medical Center. Cases of DBS infection were identified using standardized clinical and microbiological criteria. Results. Between January 1998 and September 2003,228 DBSs were implanted. Forty-seven operations (20.6%) were performed in the conventional OR and 181 (79.4%) in the MR imaging-equipped OR. There was definite infection in 13 cases (5.7%) and possible infection in 7 cases (3%), for an overall infection rate of 8.7% (20 of 228 cases). There was no significant difference in infection rates in the conventional (7 [14.89%] of 47) versus MR imaging-equipped OR (13 [7.18%] of 181) (p = 0.7). Staphylococcus aureus was isolated in 62% of cases. Twelve of 13 confirmed cases underwent complete hardware removal. On case-control analysis, younger age (<=. 58.5 years) was a significant predictor of DBS infection (odds ratio 3.4, p = 0.027) Conclusions. Infection is a serious complication of DBS implantation and commonly requires device removal for cure. The authors found that DBS implantation can be safely performed in MR imaging-equipped suites, possibly allowing improved lead placement. Young age was associated with an increased risk of DBS infection. (DOI: 10.3171/2008.6.17603)
引用
收藏
页码:239 / 246