Effect of active chilled beam layouts on ventilation performance and thermal comfort under variable heat gain conditions

被引:5
|
作者
Ming, Ru [1 ,2 ]
Mustakallio, Panu [3 ,4 ]
Kosonen, Risto [4 ,5 ]
Kaukola, Tuomas [3 ]
Kilpelainen, Simo [4 ]
Li, Baizhan [1 ,2 ]
Wu, Yuxin [6 ]
Yao, Runming [1 ,2 ,7 ]
机构
[1] Chongqing Univ, Minist Educ, Joint Int Res Lab Green Bldg & Built Environm, Chongqing 400045, Peoples R China
[2] Chongqing Univ, Minist Sci & Technol, Natl Ctr Int Res Low Carbon & Green Bldg, Chongqing 400045, Peoples R China
[3] Halton Oy, Helsinki, Finland
[4] Aalto Univ, Dept Mech Engn, Espoo 02150, Finland
[5] Nanjing Tech Univ, Coll Urban Construct, Nanjing 211899, Peoples R China
[6] Zhejiang Sci Tech Univ, Sch Civil Engn & Architecture, Hangzhou 310018, Peoples R China
[7] Univ Reading, Sch Built Environm, Reading RG6 6DB, Berks, England
关键词
4-way active chilled beam system; Thermal comfort; Air distribution; Terminal layout; Heat gain level; AIR-FLOW PATTERN; SYSTEMS; QUALITY; ENVIRONMENT; DRAFT;
D O I
10.1016/j.buildenv.2022.109872
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The active chilled beam system has been popularly used in office and meeting rooms. There are very few studies of their terminal configuration on the thermal comfort and ventilation performance of systems with different heat gains. A comparative experimental study was implemented in mock-up office and meeting rooms to provide a comprehensive evaluation of the airflow patterns, air distribution, ventilation effectiveness, and local thermal comfort of the 4-way system. Four different terminal layouts with two types of the chilled beams (600 unit and 1200 unit sized 0.6 m x 0.6 m and 1.2 m x 0.6 m, respectively) were tested at three heat gain levels: low (46W/ m2) and medium (66W/m2) heat gains in the office room, and high (92W/m2) heat gain in the meeting room. The results revealed that the terminal layouts and heat gain levels had significant effects on air distribution and local thermal comfort. The increased heat gains generated lower heat removal effectiveness, worse indoor thermal uniformity, and increased risk of draught. Generally, the 1200-unit system performed better than that with 600 units for heat removal effectiveness and contaminant removal effectiveness. In terms of local thermal comfort, the 600-unit system generally provided higher performance than that with the 1200-unit system. The practical recommendations for the system design and operation stages are provided based on the operating range of the 4-way systems under variable terminal layouts and heat gain conditions.
引用
收藏
页数:14
相关论文
共 50 条
  • [21] Performance comparison of heat exchangers with different circuitry arrangements for active chilled beam applications
    Chen, Can
    Cai, Wenjian
    Wang, Youyi
    Lin, Chen
    ENERGY AND BUILDINGS, 2014, 79 : 164 - 172
  • [22] EFFECTS OF EXHAUST LOCATION AND NUMBER ON THERMAL COMFORT PERFORMANCE UNDER STRATUM VENTILATION
    Li, Cong
    Ye, Wei-Biao
    Zhang, Da-Bing
    Hong, Yu-Xiang
    Huang, Si-Min
    COMPUTATIONAL THERMAL SCIENCES, 2018, 10 (01): : 23 - 46
  • [23] Performance Evaluation of Active Chilled Beam in Real Office Conditions in a High-Performance Building in Heating
    Upadhyay, Rohit
    Mora, Rodrigo
    ASHRAE TRANSACTIONS 2019, VOL 125, PT 1, 2019, 125 : 238 - 246
  • [24] Effect of natural ventilation mode on thermal comfort and ventilation performance: Full-scale measurement
    Omrani, Sara
    Garcia-Hansen, Veronica
    Capra, Bianca R.
    Drogemuller, Robin
    ENERGY AND BUILDINGS, 2017, 156 : 1 - 16
  • [25] A model-based multi-objective optimization of energy consumption and thermal comfort for active chilled beam systems
    Wu, Bingjie
    Cai, Wenjian
    Chen, Haoran
    APPLIED ENERGY, 2021, 287
  • [26] Operating characteristics and efficiencies of an active chilled beam terminal unit under variable air volume mode
    Chen, Can
    Cai, Wenjian
    Wang, Youyi
    Lin, Chen
    Wang, Lei
    APPLIED THERMAL ENGINEERING, 2015, 85 : 71 - 79
  • [27] Crosswinds Effect on the Thermal Performance of Wet Cooling Towers Under Variable Operating Conditions
    Chen, You Liang
    Shi, Yong Feng
    Hao, Jian Gang
    Chang, Hao
    Sun, Feng Zhong
    2017 INTERNATIONAL CONFERENCE ON POWER AND ENERGY ENGINEERING, 2018, 114
  • [28] Experimental investigation on the control performance of an active chilled beam system under dynamic cooling loads
    Rhee, Kyu-Nam
    Choi, Sun-Ho
    Tsouvalas, Agisilaos
    APPLIED THERMAL ENGINEERING, 2021, 194
  • [29] Effect of different raising systems on the thermal environment comfort and swine productive performance under spring conditions
    Cordeiro, Marcelo Bastos
    Ferreira Tinoco, Ilda de Fatima
    Victoria de Oliveira, Paulo Armando
    Menegali, Irene
    de Carvalho Guimaraes, Maria Clara
    Baeta, Fernando da Costa
    da Silva, Jadir Nogueira
    REVISTA BRASILEIRA DE ZOOTECNIA-BRAZILIAN JOURNAL OF ANIMAL SCIENCE, 2007, 36 (05): : 1597 - 1602
  • [30] THERMAL IGNITION OF A SYSTEM UNDER CONDITIONS OF VARIABLE HEAT-LOSSES
    GELMAN, EA
    SHTESSEL, EA
    COMBUSTION EXPLOSION AND SHOCK WAVES, 1990, 26 (02) : 156 - 159