Performance Evaluation of Active Chilled Beam in Real Office Conditions in a High-Performance Building in Heating

被引:0
|
作者
Upadhyay, Rohit
Mora, Rodrigo
机构
来源
关键词
D O I
暂无
中图分类号
O414.1 [热力学];
学科分类号
摘要
Active Chilled Beams (ACB) units are air induction units that handle the cooling needs of spaces with a Limited amount of primary air. These systems are energy-efficient and are widely adopted worldwide, however, in-depth investigations on the performance of ACB systems under real office conditions are still inadequate. The performance of ACB in heating mode has not been documented and deserves close investigation. The study investigated the operation of 4-pipe ACB under heating mode in a LEED Gold Building at British Columbia Institute of Technology in Vancouver climate under steady state conditions. The air velocity and temperature distribution inside an office under heating mode were studied and found that the ACB system is effective in heating. Surface temperature distribution was found close to the setpoint temperatures. The supply velocity and supply temperature at both slots of ACB were found different. It was concluded that the difference could be uneven pressure distribution in the primary air plenum and heat exchanger design of the ACB which need further research and investigation in a controlled environment.
引用
收藏
页码:238 / 246
页数:9
相关论文
共 50 条
  • [1] Performance evaluation of active chilled beam systems for office buildings - A literature review
    Latif, Haider
    Hultmark, Goran
    Rahnama, Samira
    Maccarini, Alessandro
    Afshari, Alireza
    SUSTAINABLE ENERGY TECHNOLOGIES AND ASSESSMENTS, 2022, 52
  • [2] Empirical Energy Performance Evaluation of a High-Performance Office Building in the US Midwest
    Liu, Ran
    Zhou, Xiaohui
    Lochhead, Scott
    Haberl, Nicholas
    ASHRAE TRANSACTIONS, VOL 122, PT 1, 2016, 122 : 326 - 342
  • [3] Experimental study on the performance evaluation of active chilled beams in heating and cooling operation under varied boundary conditions
    Upadhyay, Rohit
    Mora, Rodrigo
    Jean, Marc-Antoine
    Koupriyanov, Mike
    SCIENCE AND TECHNOLOGY FOR THE BUILT ENVIRONMENT, 2020, 26 (05) : 658 - 675
  • [4] CONCEPT 22/26, A HIGH PERFORMANCE OFFICE BUILDING WITHOUT ACTIVE HEATING, COOLING AND VENTILATION SYSTEMS
    Junghans, Lars P.
    PROCEEDINGS OF THE ISES SOLAR WORLD CONFERENCE 2015, 2015, : 56 - 65
  • [5] BUILDING SIMULATION AND EVOLUTIONARY OPTIMIZATION IN THE CONCEPTUAL DESIGN OF A HIGH-PERFORMANCE OFFICE BUILDING
    Trubiano, Franca
    Roudsari, Mostapha Sadeghipour
    Ozkan, Aylin
    BUILDING SIMULATION 2013: 13TH INTERNATIONAL CONFERENCE OF THE INTERNATIONAL BUILDING PERFORMANCE SIMULATION ASSOCIATION, 2013, : 1306 - 1314
  • [6] A COMPARISON STUDY FOR ACTIVE CHILLED BEAM AND VARIABLE AIR VOLUME SYSTEMS FOR AN OFFICE BUILDING
    Yau, Y. H.
    Tam, J. H.
    CLEANER ENERGY FOR CLEANER CITIES, 2018, 152 : 378 - 383
  • [7] High-Performance Office Space
    Laing, Andrew
    Craig, David
    White, Alex
    HARVARD BUSINESS REVIEW, 2011, 89 (09) : 32 - 33
  • [8] High-performance building
    Fortmeyer, Russell
    ARCHITECTURAL RECORD, 2007, 195 (10) : 170 - 170
  • [9] High-Performance Building
    Fisk, David
    INTERNATIONAL JOURNAL OF AMBIENT ENERGY, 2009, 30 (02) : 112 - 112
  • [10] Experimental study on energy performance of active chilled beam systems
    Nam D.
    Zhai Z.
    Science and Technology for the Built Environment, 2019, 25 (10) : 1369 - 1379