Experimental study on energy performance of active chilled beam systems

被引:5
|
作者
Nam D. [1 ]
Zhai Z. [1 ]
机构
[1] Department of Civil, Environmental and Architectural Engineering, University of Colorado Boulder, 1111 Engineering Dr., 428 UCB, Boulder, 80309-0401, CO
关键词
16;
D O I
10.1080/23744731.2019.1611119
中图分类号
学科分类号
摘要
Active chilled beam systems have gained attentions due to their excellent thermal and energy performance, leading to a variety of research in modeling and experimentation. However, few experimental studies have examined the detailed energy and thermal performance of active chilled beam systems with different combinations of supply air and water conditions. This study tested the cooling performance of six representative active chilled beam systems in a full-scale laboratory to analyze the air-side and water-side cooling capacity and associated impact factors. Particularly, the research explored the influences of supply airflow rate and the cooling coil water supply temperature on the energy performance of active chilled beams. The study further validated the impacts of air supply nozzle sizes of active chilled beams on cooling performance. © 2019, Copyright © 2019 ASHRAE.
引用
收藏
页码:1369 / 1379
页数:10
相关论文
共 50 条
  • [1] Performance evaluation of active chilled beam systems for office buildings - A literature review
    Latif, Haider
    Hultmark, Goran
    Rahnama, Samira
    Maccarini, Alessandro
    Afshari, Alireza
    SUSTAINABLE ENERGY TECHNOLOGIES AND ASSESSMENTS, 2022, 52
  • [2] Numerical optimization and experimental study of an active chilled beam with high entrainment efficiency
    Wen, Shihao
    Liu, Junjie
    Zhang, Jiaxin
    Liu, Sumei
    APPLIED THERMAL ENGINEERING, 2024, 255
  • [3] Experimental study of the energy and thermal comfort performance of chilled ceiling panels
    Fonseca Diaz, Nestor
    Cuevas, Cristian
    HVAC&R RESEARCH, 2011, 17 (03): : 377 - 393
  • [4] Experimental investigation on the control performance of an active chilled beam system under dynamic cooling loads
    Rhee, Kyu-Nam
    Choi, Sun-Ho
    Tsouvalas, Agisilaos
    APPLIED THERMAL ENGINEERING, 2021, 194
  • [5] Experimental investigation on airflow pattern for active chilled beam system
    Wu, Bingjie
    Cai, Wenjian
    Chen, Haoran
    Ji, Ke
    ENERGY AND BUILDINGS, 2018, 166 : 438 - 449
  • [6] A multi-objective optimization of energy consumption and thermal comfort for active chilled beam systems
    Wu, Bingjie
    Cai, Wenjian
    PROCEEDINGS OF THE 2021 IEEE 16TH CONFERENCE ON INDUSTRIAL ELECTRONICS AND APPLICATIONS (ICIEA 2021), 2021, : 1719 - 1723
  • [7] Optimization Study On The Location Of An Active Chilled Beam: Effect On Thermal Comfort And Energy Consumption
    Ghanta, Nikhilesh
    Coflan, Barry
    Glicksman, Leon
    PROCEEDINGS OF BUILDING SIMULATION 2019: 16TH CONFERENCE OF IBPSA, 2020, : 663 - 671
  • [8] A COMPARISON STUDY FOR ACTIVE CHILLED BEAM AND VARIABLE AIR VOLUME SYSTEMS FOR AN OFFICE BUILDING
    Yau, Y. H.
    Tam, J. H.
    CLEANER ENERGY FOR CLEANER CITIES, 2018, 152 : 378 - 383
  • [9] Efficient Space Humidity Control With Active Chilled Beam Systems
    Loudermilk, Kenneth J.
    Alexander, Darren S.
    ASHRAE JOURNAL, 2012, 54 (01) : 28 - +
  • [10] A full-scale experimental set-up for assessing the energy performance of radiant wall and active chilled beam for cooling buildings
    Le Dreau, Jerome
    Heiselberg, Per
    Jensen, Rasmus Lund
    BUILDING SIMULATION, 2015, 8 (01) : 39 - 50