Motion resilience of the balanced steady-state free precession geometric solution

被引:0
|
作者
Hoff, Michael N. [1 ]
Xiang, Qing-San [2 ,3 ]
Cross, Nathan M. [4 ]
Hippe, Daniel [5 ]
Andre, Jalal B. [4 ]
机构
[1] Univ Calif San Francisco, Dept Radiol & Biomed Imaging, 185 Berry St,Suite 380, San Francisco, CA 94107 USA
[2] Univ British Columbia, Dept Phys & Astron, Vancouver, BC, Canada
[3] Univ British Columbia, Dept Radiol, Vancouver, BC, Canada
[4] Univ Washington, Dept Radiol, Seattle, WA 98195 USA
[5] Fred Hutchinson Canc Res Ctr, Clin Biostat, 1124 Columbia St, Seattle, WA 98104 USA
关键词
banding artifact; bSSFP imaging; linearized geometric solution; motion artifact; phase cycling; IMAGING SEQUENCES; SPIN-ECHO; PHASE; REMOVAL; MRI;
D O I
10.1002/mrm.29438
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose Many MRI sequences are sensitive to motion and its associated artifacts. The linearized geometric solution (LGS), a balanced steady-state free precession (bSSFP) off-resonance signal demodulation technique, is evaluated with respect to motion artifact resilience. Theory and Methods The mechanism and extent of LGS motion artifact resilience is examined in simulated, flow phantom, and in vivo clinical imaging. Motion artifact correction capabilities are decoupled from susceptibility artifact correction when feasible to permit controlled analysis of motion artifact correction when comparing the LGS with standard and phase-cycle-averaged (complex sum) bSSFP imaging. Results Simulations reveal that the LGS demonstrates motion artifact reduction capabilities similar to standard clinical bSSFP imaging techniques, with slightly greater resilience in high SNR regions and for shorter-duration motion. Flow phantom experiments assert that the LGS reduces shorter-duration motion artifact error by similar to 24%-65% relative to the complex sum, whereas reconstructions exhibit similar error reduction for constant motion. In vivo analysis demonstrates that in the internal auditory canal/orbits, the LGS was deemed to have less artifact in 24%/49% and similar artifact in 76%/51% of radiological assessments relative to the complex sum, and the LGS had less artifact in 97%/81% and similar artifact in 3%/16% of assessments relative to standard bSSFP. Only 2 of 63 assessments deemed the LGS inferior to either complex sum or standard bSSFP in terms of artifact reduction. Conclusion The LGS provides sufficient bSSFP motion artifact resilience to permit robust elimination of susceptibility artifacts, inspiring its use in a wide variety of applications.
引用
收藏
页码:192 / 204
页数:13
相关论文
共 50 条
  • [41] Clinical Applications of Cine Balanced Steady-State Free Precession MRI for the Evaluation of the Subarachnoid Spaces
    Li, A. E.
    Wilkinson, M. D.
    McGrillen, K. M.
    Stoodley, M. A.
    Magnussen, J. S.
    CLINICAL NEURORADIOLOGY, 2015, 25 (04) : 349 - 360
  • [42] MTR variations in normal adult brain structures using balanced steady-state free precession
    Meritxell Garcia
    Monika Gloor
    Oliver Bieri
    Stephan G. Wetzel
    Ernst-Wilhelm Radue
    Klaus Scheffler
    Neuroradiology, 2011, 53 : 159 - 167
  • [43] Practical Applications of Balanced Steady-State Free-Precession (bSSFP) Imaging in the Abdomen and Pelvis
    Schieda, Nicola
    Isupov, Inga
    Chung, Andrew
    Coffey, Niamh
    Avruch, Leonard
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2017, 45 (01) : 11 - 20
  • [44] Investigating exchange and multicomponent relaxation in fully-balanced steady-state free precession imagaing
    Deoni, Sean C. L.
    Rutt, Brian K.
    Jones, Derek K.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2008, 27 (06) : 1421 - 1429
  • [45] MTR variations in normal adult brain structures using balanced steady-state free precession
    Garcia, Meritxell
    Gloor, Monika
    Bieri, Oliver
    Wetzel, Stephan G.
    Radue, Ernst-Wilhelm
    Scheffler, Klaus
    NEURORADIOLOGY, 2011, 53 (03) : 159 - 167
  • [46] Unenhanced MR angiography of the renal arteries with balanced steady-state free precession Dixon method
    Stafford, Randall B.
    Sabati, Mohammad
    Haakstad, Michael J.
    Mahallati, Houman
    Frayne, Richard
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2008, 191 (01) : 243 - 246
  • [47] CMR Imaging of Edema in Myocardial Infarction Using Cine Balanced Steady-State Free Precession
    Kumar, Andreas
    Beohar, Nirat
    Arumana, Jain Mangalathu
    Larose, Eric
    Li, Debiao
    Friedrich, Matthias G.
    Dharmakumar, Rohan
    JACC-CARDIOVASCULAR IMAGING, 2011, 4 (12) : 1265 - 1273
  • [48] Quantitative diffusion imaging with steady-state free precession
    Deoni, SCL
    Peters, TM
    Rutt, BK
    MAGNETIC RESONANCE IN MEDICINE, 2004, 51 (02) : 428 - 433
  • [49] STEADY-STATE FREE PRECESSION IN NUCLEAR MAGNETIC RESONANCE
    CARR, HY
    PHYSICAL REVIEW, 1958, 112 (05): : 1693 - 1701
  • [50] MR angiography using steady-state free precession
    Foo, TKF
    Ho, VB
    Marcos, HB
    Hood, MN
    Choyke, PL
    MAGNETIC RESONANCE IN MEDICINE, 2002, 48 (04) : 699 - 706