Motion resilience of the balanced steady-state free precession geometric solution

被引:0
|
作者
Hoff, Michael N. [1 ]
Xiang, Qing-San [2 ,3 ]
Cross, Nathan M. [4 ]
Hippe, Daniel [5 ]
Andre, Jalal B. [4 ]
机构
[1] Univ Calif San Francisco, Dept Radiol & Biomed Imaging, 185 Berry St,Suite 380, San Francisco, CA 94107 USA
[2] Univ British Columbia, Dept Phys & Astron, Vancouver, BC, Canada
[3] Univ British Columbia, Dept Radiol, Vancouver, BC, Canada
[4] Univ Washington, Dept Radiol, Seattle, WA 98195 USA
[5] Fred Hutchinson Canc Res Ctr, Clin Biostat, 1124 Columbia St, Seattle, WA 98104 USA
关键词
banding artifact; bSSFP imaging; linearized geometric solution; motion artifact; phase cycling; IMAGING SEQUENCES; SPIN-ECHO; PHASE; REMOVAL; MRI;
D O I
10.1002/mrm.29438
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose Many MRI sequences are sensitive to motion and its associated artifacts. The linearized geometric solution (LGS), a balanced steady-state free precession (bSSFP) off-resonance signal demodulation technique, is evaluated with respect to motion artifact resilience. Theory and Methods The mechanism and extent of LGS motion artifact resilience is examined in simulated, flow phantom, and in vivo clinical imaging. Motion artifact correction capabilities are decoupled from susceptibility artifact correction when feasible to permit controlled analysis of motion artifact correction when comparing the LGS with standard and phase-cycle-averaged (complex sum) bSSFP imaging. Results Simulations reveal that the LGS demonstrates motion artifact reduction capabilities similar to standard clinical bSSFP imaging techniques, with slightly greater resilience in high SNR regions and for shorter-duration motion. Flow phantom experiments assert that the LGS reduces shorter-duration motion artifact error by similar to 24%-65% relative to the complex sum, whereas reconstructions exhibit similar error reduction for constant motion. In vivo analysis demonstrates that in the internal auditory canal/orbits, the LGS was deemed to have less artifact in 24%/49% and similar artifact in 76%/51% of radiological assessments relative to the complex sum, and the LGS had less artifact in 97%/81% and similar artifact in 3%/16% of assessments relative to standard bSSFP. Only 2 of 63 assessments deemed the LGS inferior to either complex sum or standard bSSFP in terms of artifact reduction. Conclusion The LGS provides sufficient bSSFP motion artifact resilience to permit robust elimination of susceptibility artifacts, inspiring its use in a wide variety of applications.
引用
收藏
页码:192 / 204
页数:13
相关论文
共 50 条
  • [21] Magnetization evolution in balanced steady-state free precession with continuously moving table
    Stafford, Randall B.
    Sabati, Mohammad
    Mahallati, Houman
    Frayne, Richard
    PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (08): : N173 - N184
  • [22] Intrinsic fat suppression in TIDE balanced steady-state free precession imaging
    Paul, Dominik
    Hennig, Juergen
    Zaitsev, Maxim
    MAGNETIC RESONANCE IN MEDICINE, 2006, 56 (06) : 1328 - 1335
  • [23] INTRAVOXEL INCOHERENT MOTION IMAGING USING STEADY-STATE FREE PRECESSION
    LEBIHAN, D
    MAGNETIC RESONANCE IN MEDICINE, 1988, 7 (03) : 346 - 351
  • [25] Analytical Solution to the Transient Phase of Steady-State Free Precession Sequences
    Ganter, Carl
    MAGNETIC RESONANCE IN MEDICINE, 2009, 62 (01) : 149 - 164
  • [26] Analytical Characterization of RF Phase-Cycled Balanced Steady-State Free Precession
    Lauzon, M. Louis
    Frayne, Richard
    CONCEPTS IN MAGNETIC RESONANCE PART A, 2009, 34A (03) : 133 - 143
  • [27] Parameter Estimation Approach to Banding Artifact Reduction in Balanced Steady-State Free Precession
    Bjork, Marcus
    Ingle, R. Reeve
    Gudmundson, Erik
    Stoica, Petre
    Nishimura, Dwight G.
    Barral, Joelle K.
    MAGNETIC RESONANCE IN MEDICINE, 2014, 72 (03) : 880 - 892
  • [28] Fat and water separation in balanced steady-state free precession using the Dixon method
    Huang, TY
    Chung, HW
    Wang, FN
    Ko, CW
    Chen, CY
    MAGNETIC RESONANCE IN MEDICINE, 2004, 51 (02) : 243 - 247
  • [29] Physiological and Functional Magnetic Resonance Imaging Using Balanced Steady-state Free Precession
    Park, Sung-Hong
    Han, Paul Kyu
    Choi, Seung Hong
    KOREAN JOURNAL OF RADIOLOGY, 2015, 16 (03) : 550 - 559
  • [30] Use of Balanced Steady-State Free Precession Sequences in Evaluation of Drop Metastases Reply
    Buch, K.
    Rincon, S.
    Caruso, P.
    Kirsch, J. E.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2019, 40 (05) : E21 - E21