Creating uniform cluster dose spread-out Bragg peaks for proton and carbon beams

被引:0
|
作者
Ortiz, Ramon [1 ,2 ]
Faddegon, Bruce [1 ]
机构
[1] Univ Calif San Francisco, Dept Radiat Oncol, San Francisco, CA USA
[2] 1600 Divisadero St, San Francisco, CA 94115 USA
基金
美国国家卫生研究院;
关键词
cluster dose; ionization detail; Monte Carlo; nanodosimetry; particle therapy; TRACK STRUCTURE; NANODOSIMETRY; THERAPY; TOPAS; IONS;
D O I
10.1002/mp.16991
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
BackgroundPreliminary data have shown a close association of the generalized ionization cluster size dose (in short, cluster dose) with cell survival, independent of particle type, and energy, when cluster dose is derived from an ionization detail parameter preferred for its association with cell survival. Such results suggest cluster dose has the potential to replace RBE-weighted dose in proton and ion beam radiotherapy treatment plan optimization, should a uniform cluster dose lead to comparable biological effects. However, further preclinical investigations are warranted to confirm this premise.PurposeTo present an analytical approach to create uniform cluster dose spread-out Bragg peaks (SOBP) for evaluation of the potential of cluster dose to result in uniform biological effect.MethodsWe modified the coefficients of the Bortfeld and Schlegel weight formula, an analytical method typically used for the creation of radiation dose SOBP in particle therapy, to produce uniform cluster dose SOBP of different widths (1-5 cm) at relevant clinical proton and carbon beam energies. Optimum parameters were found by minimization of the ratio between the maximum and minimum cluster dose in the SOBP region using the Nelder-Mead method.ResultsThe coefficients of the Bortfeld and Schlegel weight formula leading to uniform cluster dose SOBPs were determined for each combination of beam energy and SOBP width studied. The uniformity of the resulting cluster dose SOBPs, calculated as the relative difference between the maximum and minimum cluster dose within the SOBP, was within 0.3%-3.5% for the evaluated proton beams and 1.3%-3.4% for the evaluated carbon beams.ConclusionsThe modifications to the analytical approach to create radiation dose SOBPs resulted in uniform cluster dose proton and carbon SOBPs over a wide range of beam energies and SOBP widths. Such SOBPs should prove valuable in preclinical investigations for the selection of nanodosimetric quantities to be used in proton and ion therapy treatment planning.
引用
收藏
页码:4482 / 4488
页数:7
相关论文
共 50 条
  • [21] Characteristics of optically stimulated luminescence dosimeters in the spread-out Bragg peak region of clinical proton beams
    Kerns, James R.
    Kry, Stephen F.
    Sahoo, Narayan
    MEDICAL PHYSICS, 2012, 39 (04) : 1854 - 1863
  • [22] An analytical reconstruction model of the spread-out Bragg peak using laser-accelerated proton beams
    Tao, Li
    Zhu, Kun
    Zhu, Jungao
    Xu, Xiaohan
    Lin, Chen
    Ma, Wenjun
    Lu, Haiyang
    Zhao, Yanying
    Lu, Yuanrong
    Chen, Jia-er
    Yan, Xueqing
    PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (13): : 5200 - 5212
  • [23] Optimization of current modulation function for proton spread-out Bragg peak fields
    Lu, HM
    Kooy, H
    MEDICAL PHYSICS, 2006, 33 (05) : 1281 - 1287
  • [24] Practical biological spread-out Bragg peak design for a carbon beam
    Chang Hyeuk Kim
    Hwa-Ryun Lee
    Seduk Chang
    Hong Suk Jang
    Jeong Hwan Kim
    Dong Wook Park
    Won Taek Hwang
    Tea-Keun Yang
    Journal of the Korean Physical Society, 2015, 67 : 1440 - 1443
  • [25] Practical biological spread-out Bragg peak design for a carbon beam
    Kim, Chang Hyeuk
    Lee, Hwa-Ryun
    Chang, Seduk
    Jang, Hong Suk
    Kim, Jeong Hwan
    Park, Dong Wook
    Hwang, Won Taek
    Yang, Tea-Keun
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2015, 67 (08) : 1440 - 1443
  • [26] Biological Quality Assurance of Carbon-ion Beam Irradiation at Spread-out Bragg Peak (SOBP) Beams
    Takahashi, T.
    Yoshida, Y.
    Musha, A.
    Ando, K.
    Furusawa, Y.
    Kanai, T.
    Murata, K.
    Takahashi, A.
    Ohno, T.
    Nakano, T.
    EUROPEAN JOURNAL OF CANCER, 2011, 47 : S197 - S197
  • [27] PREDICTION OF OUTPUT FACTOR, RANGE, AND SPREAD-OUT BRAGG PEAK FOR PROTON THERAPY
    Kim, Dong Wook
    Lim, Young Kyung
    Ahn, Sung Hwan
    Shin, Jungwook
    Shin, Dongho
    Yoon, Myongguen
    Lee, Se Byeong
    Kim, Dae Yong
    Park, Sung Yong
    MEDICAL DOSIMETRY, 2011, 36 (02) : 145 - 152
  • [28] Investigating the impact of a variable RBE on proton dose fractionation across an actively scanned spread-out Bragg peak
    Prise, K. M.
    Marshall, T. I.
    Chaudhary, P.
    Michaelidesova, A.
    Vachelova, J.
    Davidkova, M.
    Vondracek, V.
    Schettino, G.
    RADIOTHERAPY AND ONCOLOGY, 2016, 118 : S87 - S88
  • [29] Radiobiological significance of beamline dependent proton energy distributions in a spread-out Bragg peak
    Paganetti, H
    Goitein, M
    MEDICAL PHYSICS, 2000, 27 (05) : 1119 - 1126
  • [30] The prediction of output factors for spread-out proton Bragg peak fields in clinical practice
    Kooy, HM
    Rosenthal, SJ
    Engelsman, M
    Mazal, A
    Slopsema, RL
    Paganetti, H
    Flanz, JB
    PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (24): : 5847 - 5856