Practical biological spread-out Bragg peak design for a carbon beam

被引:0
|
作者
Chang Hyeuk Kim
Hwa-Ryun Lee
Seduk Chang
Hong Suk Jang
Jeong Hwan Kim
Dong Wook Park
Won Taek Hwang
Tea-Keun Yang
机构
[1] Korea Institute of Radiological and Medical Science,
来源
关键词
Carbon beam therapy; Spread-out Bragg peak; Relative biological effectiveness;
D O I
暂无
中图分类号
学科分类号
摘要
In radiation therapy, the carbon beams has more advantages with respect to biological properties then a proton beam. The carbon beam has a high linear energy transfer (LET) to the medium and a higher relative biological effectiveness (RBE). To design the spread-out Bragg peak (SOBP) of biological dose for a carbon beam, we propose a practical method using the linear-quadratic (LQ) model and the Geant4-based Monte Carlo simulation code. Various Bragg peak profiles and LETs were calculated for each slice in the target region. To generate an appropriate biological SOBP, we applied a set of weighting factors, which are power functions in terms of energy steps, to each obtained physical dose. The designed biological SOBP showed a uniformity of 1.34%.
引用
收藏
页码:1440 / 1443
页数:3
相关论文
共 50 条
  • [1] Practical biological spread-out Bragg peak design for a carbon beam
    Kim, Chang Hyeuk
    Lee, Hwa-Ryun
    Chang, Seduk
    Jang, Hong Suk
    Kim, Jeong Hwan
    Park, Dong Wook
    Hwang, Won Taek
    Yang, Tea-Keun
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2015, 67 (08) : 1440 - 1443
  • [2] Biological Quality Assurance of Carbon-ion Beam Irradiation at Spread-out Bragg Peak (SOBP) Beams
    Takahashi, T.
    Yoshida, Y.
    Musha, A.
    Ando, K.
    Furusawa, Y.
    Kanai, T.
    Murata, K.
    Takahashi, A.
    Ohno, T.
    Nakano, T.
    EUROPEAN JOURNAL OF CANCER, 2011, 47 : S197 - S197
  • [3] Irradiation of mixed beam and design of spread-out Bragg peak for heavy-ion radiotherapy
    Kanai, T
    Furusawa, Y
    Fukutsu, K
    Itsukaichi, H
    EguchiKasai, K
    Ohara, H
    RADIATION RESEARCH, 1997, 147 (01) : 78 - 85
  • [4] Relative biological effectiveness in a proton spread-out Bragg peak formed by pencil beam scanning mode
    Anna Michaelidesová
    Jana Vachelová
    Monika Puchalska
    Kateřina Pachnerová Brabcová
    Vladimír Vondráček
    Lembit Sihver
    Marie Davídková
    Australasian Physical & Engineering Sciences in Medicine, 2017, 40 : 359 - 368
  • [5] Relative biological effectiveness in a proton spread-out Bragg peak formed by pencil beam scanning mode
    Michaelidesova, Anna
    Vachelova, Jana
    Puchalska, Monika
    Brabcova, Katerina Pachnerova
    Vondracek, Vladimir
    Sihver, Lembit
    Davidkova, Marie
    AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2017, 40 (02) : 359 - 368
  • [6] Creating a spread-out Bragg peak in proton beams
    Jette, David
    Chen, Weimin
    PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (11): : N131 - N138
  • [7] SPREAD-OUT BRAGG PEAK IN SPATIALLY FRACTIONATED PROTON THERAPY
    Institute of Nuclear Physics, Polish Academy of Sciences, Radzikowskiego 152, Kraków
    31-342, Poland
    Acta Phys. Pol. B Proc. Suppl., 1899, 4
  • [8] SPREAD-OUT BRAGG PEAK IN SPATIALLY FRACTIONATED PROTON THERAPY
    Tobola-Galus, Agata
    Swakon, Jan
    Olko, Pawel
    ACTA PHYSICA POLONICA B PROCEEDINGS SUPPLEMENT, 2022, 15 (04)
  • [9] Design of a ridge filter for spread-out Bragg-peak production in a pulsed 100-MeV proton beam
    Jung, Myung-Hwan
    Ra, Se-Jin
    Kim, Kye-Ryung
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2013, 63 (07) : 1441 - 1445
  • [10] Design of a ridge filter for spread-out Bragg-peak production in a pulsed 100-MeV proton beam
    Myung-Hwan Jung
    Se-Jin Ra
    Kye-Ryung Kim
    Journal of the Korean Physical Society, 2013, 63 : 1441 - 1445