Practical biological spread-out Bragg peak design for a carbon beam

被引:0
|
作者
Chang Hyeuk Kim
Hwa-Ryun Lee
Seduk Chang
Hong Suk Jang
Jeong Hwan Kim
Dong Wook Park
Won Taek Hwang
Tea-Keun Yang
机构
[1] Korea Institute of Radiological and Medical Science,
来源
关键词
Carbon beam therapy; Spread-out Bragg peak; Relative biological effectiveness;
D O I
暂无
中图分类号
学科分类号
摘要
In radiation therapy, the carbon beams has more advantages with respect to biological properties then a proton beam. The carbon beam has a high linear energy transfer (LET) to the medium and a higher relative biological effectiveness (RBE). To design the spread-out Bragg peak (SOBP) of biological dose for a carbon beam, we propose a practical method using the linear-quadratic (LQ) model and the Geant4-based Monte Carlo simulation code. Various Bragg peak profiles and LETs were calculated for each slice in the target region. To generate an appropriate biological SOBP, we applied a set of weighting factors, which are power functions in terms of energy steps, to each obtained physical dose. The designed biological SOBP showed a uniformity of 1.34%.
引用
收藏
页码:1440 / 1443
页数:3
相关论文
共 50 条
  • [21] A new approach to produce spread-out Bragg peak using the MINUIT fit
    Park, Inkyu
    CURRENT APPLIED PHYSICS, 2009, 9 (04) : 852 - 855
  • [22] PREDICTION OF OUTPUT FACTOR, RANGE, AND SPREAD-OUT BRAGG PEAK FOR PROTON THERAPY
    Kim, Dong Wook
    Lim, Young Kyung
    Ahn, Sung Hwan
    Shin, Jungwook
    Shin, Dongho
    Yoon, Myongguen
    Lee, Se Byeong
    Kim, Dae Yong
    Park, Sung Yong
    MEDICAL DOSIMETRY, 2011, 36 (02) : 145 - 152
  • [23] Cell survival probability in a spread-out Bragg peak for novel treatment planning
    Eugene Surdutovich
    Andrey V. Solov’yov
    The European Physical Journal D, 2017, 71
  • [24] A deep learning method for predicting proton beam range and spread-out Bragg peak in passive scattering mode
    Lee, Younggyu
    Ahn, Sang Hee
    Kim, Chankyu
    Cheon, Wonjoong
    Kim, Haksoo
    Lee, Se Byeong
    Lim, Young Kyung
    Jeong, Jong Hwi
    Kang, Young-Nam
    Shin, Dongho
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2024, 85 (03) : 256 - 266
  • [25] Assessment of the homogeneous efficacy of carbon ions in the spread-out Bragg peak for human lung cancer cell lines
    Takiguchi Y.
    Miyamoto T.
    Nagao K.
    Kuriyama T.
    Radiation Medicine, 2007, 25 (6): : 272 - 277
  • [26] Design of spread-out Bragg peaks in hadron therapy with oxygen ions
    Rezaee, Ladan
    REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2018, 23 (05) : 433 - 441
  • [27] Radiobiological significance of beamline dependent proton energy distributions in a spread-out Bragg peak
    Paganetti, H
    Goitein, M
    MEDICAL PHYSICS, 2000, 27 (05) : 1119 - 1126
  • [28] A method for achieving variable widths of the spread-out Bragg peak using a ridge filter
    Nakagawa, T
    Yoda, K
    MEDICAL PHYSICS, 2000, 27 (04) : 712 - 715
  • [29] Monitor unit calculations for range-modulated spread-out Bragg peak fields
    Kooy, HM
    Schaefer, M
    Rosenthal, S
    Bortfeld, T
    PHYSICS IN MEDICINE AND BIOLOGY, 2003, 48 (17): : 2797 - 2808
  • [30] Response of mouse intestine after single and fractionated irradiation with accelerated carbon ions with a spread-out Bragg peak
    Fukutsu, K
    Kanai, T
    Furusawa, Y
    Ando, K
    RADIATION RESEARCH, 1997, 148 (02) : 168 - 174