Dual- and multi-energy CT for particle stopping-power estimation: current state, challenges and potential

被引:17
|
作者
Yang, Ming [1 ]
Wohlfahrt, Patrick [2 ]
Shen, Chenyang [3 ]
Bouchard, Hugo [4 ,5 ,6 ]
机构
[1] Univ Texas MD Anderson Canc Ctr, Dept Radiat Phys, 1515 Holcombe Blvd, Houston, TX 77030 USA
[2] Harvard Med Sch, Massachusetts Gen Hosp, Dept Radiat Oncol, Boston, MA 02115 USA
[3] Univ Texas Southwestern Med Ctr, Dept Radiat Oncol, 2280 Inwood Rd, Dallas, TX 75235 USA
[4] Univ Montreal, Dept Phys, Complexe Sci, 1375 Ave Therese-Lavoie-Roux, Montreal, PQ H2V0B3, Canada
[5] Ctr Rech Ctr Univ Univ Montreal, 900 Rue St-Denis, Montreal, PQ H2X 0A9, Canada
[6] Ctr Hosp Univ Montreal, Dept Radiooncol, 1051 Rue Sanguinet, Montreal, PQ H2X 3E4, Canada
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2023年 / 68卷 / 04期
关键词
dual-energy CT; multi-energy CT; photon-counting CT; particle therapy; stopping power; range uncertainty; treatment planning; ENERGY COMPUTED-TOMOGRAPHY; METAL ARTIFACT REDUCTION; MONTE-CARLO SIMULATIONS; EFFECTIVE ATOMIC-NUMBER; VIRTUAL NON-CONTRAST; ELECTRON-DENSITY; CLINICAL IMPLEMENTATION; RANGE UNCERTAINTIES; PROTON THERAPY; COMPREHENSIVE ANALYSIS;
D O I
10.1088/1361-6560/acabfa
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Range uncertainty has been a key factor preventing particle radiotherapy from reaching its full physical potential. One of the main contributing sources is the uncertainty in estimating particle stopping power (rho ( s )) within patients. Currently, the rho ( s ) distribution in a patient is derived from a single-energy CT (SECT) scan acquired for treatment planning by converting CT number expressed in Hounsfield units (HU) of each voxel to rho ( s ) using a Hounsfield look-up table (HLUT), also known as the CT calibration curve. HU and rho ( s ) share a linear relationship with electron density but differ in their additional dependence on elemental composition through different physical properties, i.e. effective atomic number and mean excitation energy, respectively. Because of that, the HLUT approach is particularly sensitive to differences in elemental composition between real human tissues and tissue surrogates as well as tissue variations within and among individual patients. The use of dual-energy CT (DECT) for rho ( s ) prediction has been shown to be effective in reducing the uncertainty in rho ( s ) estimation compared to SECT. The acquisition of CT data over different x-ray spectra yields additional information on the material elemental composition. Recently, multi-energy CT (MECT) has been explored to deduct material-specific information with higher dimensionality, which has the potential to further improve the accuracy of rho ( s ) estimation. Even though various DECT and MECT methods have been proposed and evaluated over the years, these approaches are still only scarcely implemented in routine clinical practice. In this topical review, we aim at accelerating this translation process by providing: (1) a comprehensive review of the existing DECT/MECT methods for rho ( s ) estimation with their respective strengths and weaknesses; (2) a general review of uncertainties associated with DECT/MECT methods; (3) a general review of different aspects related to clinical implementation of DECT/MECT methods; (4) other potential advanced DECT/MECT applications beyond rho ( s ) estimation.
引用
收藏
页数:24
相关论文
共 43 条
  • [31] Accuracy of proton stopping power estimation of silicone breast implants with single and dual-energy CT calibration techniques
    Chacko, Michael S.
    Grewal, Hardev S.
    Wu, Dee
    Sonnad, Jagadeesh R.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2021, 22 (09): : 159 - 170
  • [32] The Optimization of Spectra Gap for Proton Stopping Power Estimation Using Dual-Energy CT Image Domain Method
    Han, D.
    Zhang, S.
    Ding, K.
    MEDICAL PHYSICS, 2020, 47 (06) : E664 - E664
  • [33] Basis Vector Model Based Method for Proton Stopping Power Estimation From Experimental Dual Energy CT Data
    Zhang, S.
    Han, D.
    Politte, D.
    Porras-Chaverri, M.
    Whiting, B.
    Williamson, J.
    O'Sullivan, J.
    MEDICAL PHYSICS, 2016, 43 (06) : 3756 - 3756
  • [34] Refinement of the Hounsfield look-up table by retrospective application of patient-specific direct proton stopping-power prediction from dual-energy CT
    Wohlfahrt, Patrick
    Moehler, Christian
    Enghardt, Wolfgang
    Krause, Mechthild
    Kunath, Daniela
    Menkel, Stefan
    Troost, Esther G. C.
    Greilich, Steffen
    Richter, Christian
    MEDICAL PHYSICS, 2020, 47 (04) : 1796 - 1812
  • [35] Optimal energy selection for proton stopping-power-ratio estimation using dual-energy CT-based monoenergetic imaging
    Je, Euikyu
    Lee, Hugh H. C.
    Duan, Xinhui
    Li, Bin
    Jia, Xun
    Yang, Ming
    PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (19):
  • [36] Systematic analysis of the impact of imaging noise on dual-energy CT-based proton stopping power ratio estimation
    Lee, Hugh H. C.
    Li, Bin
    Duan, Xinhui
    Zhou, Linghong
    Jia, Xun
    Yang, Ming
    MEDICAL PHYSICS, 2019, 46 (05) : 2251 - 2263
  • [37] Convolutional neural network based proton stopping-power-ratio estimation with dual-energy CT: a feasibility study
    Lee, H. Hc
    Park, Y. K.
    Duan, X.
    Jia, X.
    Jiang, S.
    Yang, M.
    PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (21):
  • [38] Towards subpercentage uncertainty proton stopping-power mapping via dual-energy CT: Direct experimental validation and uncertainty analysis of a statistical iterative image reconstruction method
    Medrano, Maria
    Liu, Ruirui
    Zhao, Tianyu
    Webb, Tyler
    Politte, David G.
    Whiting, Bruce R.
    Liao, Rui
    Ge, Tao
    Porras-Chaverri, Mariela A.
    O'Sullivan, Joseph A.
    Williamson, Jeffrey F.
    MEDICAL PHYSICS, 2022, 49 (03) : 1599 - 1618
  • [39] Comment on: Dosimetric comparison of stopping-power calibration with dual-energy CT and single-energy CT in proton therapy treatment planning [Med. Phys. 43(6), 2845-2854 (2016)]
    Wohlfahrt, Patrick
    Moehler, Christian
    Greilich, Steffen
    Richter, Christian
    MEDICAL PHYSICS, 2017, 44 (10) : 5533 - 5536
  • [40] Comprehensive analysis of proton range uncertainties related to stopping-power-ratio estimation using dual-energy CT imaging
    Li, B.
    Lee, H. C.
    Duan, X.
    Shen, C.
    Zhou, L.
    Jia, X.
    Yang, M.
    PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (17): : 7056 - 7074