摘要
ULTRASAT (ULtraviolet TRansient Astronomy SATellite) is a wide-angle space telescope that will perform deep time-resolved surveys in the near-ultraviolet spectrum. ULTRASAT is a space mission led by the Weizmann Institute of Science and the Israel Space Agency and is planned for launch in 2025. The camera implements backside-illuminated, stitched pixel sensors. The pixel has a dual-conversion-gain 4T architecture, with a pitch of 9.5 mu m and is produced in a 180 nm process by Tower Semiconductor. Before the final sensor was available for testing, test sensors provided by Tower were used to gain first insights into the pixel's radiation tolerance. One of the main contributions to sensor degradation due to radiation for the ULTRASAT mission is Total Ionizing Dose (TID). TID measurements on the test sensors have been performed with a Co-60 gamma source at Helmholz Zentrum Berlin and CC-60 facility at CERN and preliminary results are presented.
引用
收藏
页数:3
相关论文
共 50 条
  • [1] The design of a UV CMOS sensor for the ULTRASAT space telescope
    Liran, Tuvia
    Shvartzvald, Yossi
    Lapid, Ofer
    Ben-Ami, Sagi
    Waxman, Eli
    Netzer, Ehud
    Ofek, Eran
    Gal-Yam, Avishay
    Zappon, Francesco
    Barschke, Merlin F.
    Worm, Steven
    Vasilev, Mikhail
    Buehler, Rolf
    Berge, David
    Koifman, Vladimir
    Miller, Avi
    Mordakhay, Anatoli
    Lehana, Gadi
    Lempel, Yosef
    Levi, Andrei
    Ben-David, Oshrit
    Galambos, Tiberiu
    Birman, Adi
    Fenigstein, Amos
    Alfassi, Shay
    Katz, Omer
    Reshef, Raz
    SPACE TELESCOPES AND INSTRUMENTATION 2022: ULTRAVIOLET TO GAMMA RAY, 2022, 12181
  • [2] Total Ionizing Dose Effects on a Radiation-Hardened CMOS Image Sensor Demonstrator for ITER Remote Handling
    Goiffon, Vincent
    Rizzolo, Serena
    Corbiere, Franck
    Rolando, Sebastien
    Bounasser, Said
    Sergent, Marius
    Chabane, Aziouz
    Marcelot, Olivier
    Estribeau, Magali
    Magnan, Pierre
    Paillet, Philippe
    Girard, Sylvain
    Gaillardin, Marc
    Marcandella, Claude
    Allanche, Timothe
    Van Uffelen, Marco
    Mont Casellas, Laura
    Scott, Robin
    De Cock, Wouter
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2018, 65 (01) : 101 - 110
  • [3] Total Ionizing Dose Effects of the Color Complementary Metal Oxide Semiconductor (CMOS) Image Sensor at Different Bias
    Yang, Zhikang
    Wen, Lin
    Li, Yudong
    Liu, Bingkai
    Fu, Jing
    Feng, Jie
    Cui, Yihao
    JOURNAL OF NANOELECTRONICS AND OPTOELECTRONICS, 2022, 17 (01) : 121 - 127
  • [4] Mechanism of Total Ionizing Dose Effects of CMOS Image Sensors on Camera Resolution
    Feng, Jie
    Wang, Hai-Chuan
    Li, Yu-Dong
    Wen, Lin
    Guo, Qi
    ELECTRONICS, 2023, 12 (12)
  • [5] Total Ionizing Dose Degradation of CMOS 8-transistor Image Sensor with Column ADC
    Cherniak, M.
    Smolin, A.
    Mozhaev, R.
    Ulanova, A.
    Nikiforov, A.
    2017 IEEE 30TH INTERNATIONAL CONFERENCE ON MICROELECTRONICS (MIEL), 2017, : 271 - 274
  • [6] Radiation Hardness Comparison of CMOS Image Sensor Technologies at High Total Ionizing Dose Levels
    Rizzolo, Serena
    Goiffon, Vincent
    Corbiere, Franck
    Molina, Romain
    Chabane, Aziouz
    Girard, Sylvain
    Paillet, Philippe
    Magnan, Pierre
    Boukenter, Aziz
    Allanche, Timothe
    Muller, Cyprien
    Monsanglant-Louvet, Celine
    Osmond, Melanie
    Desjonqueres, Hortense
    Mace, Jean-Reynald
    Burnichon, Pierre
    Baudu, Jean-Pierre
    Plumeri, Stephane
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2019, 66 (01) : 111 - 119
  • [7] Total ionizing dose effects on CMOS image sensors with deep-trench isolation
    Ahmed, Nayera
    Lu, Guo-Neng
    Roy, Francois
    MATERIALS AND APPLICATIONS FOR SENSORS AND TRANSDUCERS III, 2014, 605 : 453 - 456
  • [8] High Total Ionizing Dose Effects on Backside-Illuminated CMOS Image Sensors
    Liu, Bingkai
    Li, Yudong
    Wen, Lin
    Feng, Jie
    Cai, Yulong
    Guo, Qi
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2024, 71 (11) : 2393 - 2399
  • [9] Multi-MGy Total Ionizing Dose Induced MOSFET Variability Effects on Radiation Hardened CMOS Image Sensor Performances
    Rizzolo, Serena
    Goiffon, Vincent
    Sergent, Marius
    Corbiere, Franck
    Rolando, Sebastien
    Chabane, Aziouz
    Paillet, Philippe
    Marcandella, Claude
    Girard, Sylvain
    Magnan, Pierre
    Van Uffelen, Marco
    Casellas, Laura Mont
    Scott, Robin
    De Cock, Wouter
    2017 17TH EUROPEAN CONFERENCE ON RADIATION AND ITS EFFECTS ON COMPONENTS AND SYSTEMS (RADECS), 2017, : 49 - 52
  • [10] Total dose effects in 0.5 μm CMOS active pixel image sensor
    Wang, Bo
    Li, Yu-Dong
    Guo, Qi
    Liu, Chang-Ju
    Wen, Lin
    Sun, Jing
    Ma, Li-Ya
    Faguang Xuebao/Chinese Journal of Luminescence, 2015, 36 (02): : 242 - 248