Point-of-care detection of glycated hemoglobin using a novel dry chemistry-based electrochemiluminescence device

被引:4
|
作者
Zhou, Xinya [1 ,2 ,3 ]
Lai, Wei [1 ,2 ,3 ]
Zhong, Jinbiao [1 ,2 ,3 ]
Yang, Yang [1 ,2 ,3 ]
Chen, Zhenyu [4 ]
Zhang, Chunsun [1 ,2 ,3 ]
机构
[1] South China Normal Univ, Coll Biophoton, MOE Key Lab Laser Life Sci, Guangzhou 510631, Peoples R China
[2] South China Normal Univ, Inst Laser Life Sci, Coll Biophoton, Guangzhou 510631, Peoples R China
[3] South China Normal Univ, Coll Biophoton, Guangdong Prov Key Lab Laser Life Sci, Guangzhou 510631, Peoples R China
[4] Guangzhou First Peoples Hosp, Nansha Hosp, Guangzhou 511457, Peoples R China
关键词
Enzyme biosensor; Dry chemistry; Three-electrode electrochemiluminescence; Point-of-care testing; Glycated hemoglobin detection; QUANTITATIVE DETECTION; LABEL-FREE; GLUCOSE; HBA1C; ELECTRODE; LUMINOL; ASSAY; IDENTIFICATION; PERFORMANCE; BIOSENSOR;
D O I
10.1016/j.aca.2023.341829
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
As a good biomarker to reflect the average level of blood glucose, glycated hemoglobin (HbA1c) is mainly used for long-term glycemic monitoring and risk assessment of complications in diabetic patients. Previous analysis methods for HbA1c usually require complex pretreatment processes and large-scale biochemical analyzers, which makes it difficult to realize the point-of-care testing (POCT) of HbA1c. In this work, we have proposed a three-electrode dry chemistry-based electrochemiluminescence (ECL) biosensor and its self-contained automatic ECL analyzer. In this enzymatic biosensor, fructosyl amino-caid oxidase (FAOD) reacts with the hydrolysis product of HbA1c, and the produced hydrogen peroxide further reacts with luminol under the appropriate driving voltage, generating photons to realize the quantitative detection of HbA1c. Under optimized conditions, the biosensors have a good linear response to different concentrations of fructosyl valine (FV) ranging from 0.05 to 2 mM, with a limit of detection of 2 mu M. The within-batch variation is less than 15%, and the biosensors still have 78% of the initial response after the accelerated aging test of 36 h at 37 degrees C. Furthermore, the recoveries for different concentrations of samples in whole blood were within 92.3-99.7%. These results illustrate that the proposed method has the potential for use in POCT of HbA1c.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] Improving Access to the Glycated Hemoglobin Test in Rural Communities With Point-of-Care Devices: An Application Study
    Camargo, Marianne Silveira
    Santana Passos, Luiz Carlos
    Mistro, Sostenes
    Soares, Daniela Arruda
    Kochergin, Clavdia Nickolaevna
    Honorato dos Santos de Carvalho, Vivian Carla
    Lemos Macedo, Jessica Caline
    Andrade Cortes, Taciana Borges
    de Souza, Amos Alves
    Rumel, Davi
    Oliveira, Marcio Galvao
    FRONTIERS IN MEDICINE, 2021, 8
  • [22] LABEL-FREE AND HIGH-THROUGHPUT SENSING OF GLYCATED HEMOGLOBIN FOR POINT-OF-CARE SETTING
    Pandey, Rishikesh
    Spegazzini, Nicolas
    Barman, Ishan
    Horowitz, Gary
    Lue, Niyom
    Galindo, Luis
    Dasari, Ramachandra Rao
    LASERS IN SURGERY AND MEDICINE, 2016, 48 : 4 - 4
  • [23] Integrated Anemia Detection and Hemoglobin Variant Identification Using Point-of-Care Microchip Electrophoresis
    An, Ran
    Hasan, Muhammad Noman
    Man, Yuncheng
    Gurkan, Umut A.
    BLOOD, 2019, 134
  • [24] Spectral and temporal detection of blood bilirubin level using a point-of-care device
    Ndabakuranye, Jean Pierre
    Choy, Kay Weng
    Prawer, Steven
    Ahnood, Arman
    2023 45TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE & BIOLOGY SOCIETY, EMBC, 2023,
  • [25] Analytical Challenges in Diabetes Management: Towards Glycated Albumin Point-of-Care Detection
    Rescalli, Andrea
    Varoni, Elena Maria
    Cellesi, Francesco
    Cerveri, Pietro
    BIOSENSORS-BASEL, 2022, 12 (09):
  • [26] Agarose-Based Microfluidic Device for Point-of-Care Concentration and Detection of Pathogen
    Li, Yiwei
    Yan, Xinghua
    Feng, Xiaojun
    Wang, Jie
    Du, Wei
    Wang, Yachao
    Chen, Peng
    Xiong, Liang
    Liu, Bi-Feng
    ANALYTICAL CHEMISTRY, 2014, 86 (21) : 10653 - 10659
  • [27] Nurse-based evaluation of point-of-care assays for glycated haemoglobin
    St John, A
    Davis, TME
    Goodall, I
    Townsend, MA
    Price, CP
    CLINICA CHIMICA ACTA, 2006, 365 (1-2) : 257 - 263
  • [28] Validation of a novel point-of-care nerve conduction device for the detection of diabetic sensorimotor polyneuropathy
    Perkins, Bruce A.
    Ngo, Mylan
    Grewal, Jaspreet
    Ng, Eduardo
    Bril, Vera
    DIABETES CARE, 2006, 29 (09) : 2023 - 2027
  • [29] A novel portable electrochemiluminescence detection device based on SiPM
    Yu, Changqing
    Wu, Yangbo
    2024 9TH INTERNATIONAL CONFERENCE ON ELECTRONIC TECHNOLOGY AND INFORMATION SCIENCE, ICETIS 2024, 2024, : 104 - 110
  • [30] A novel Real Time micro PCR based Point-of-Care device for Salmonella detection in human clinical samples
    Verdoy, Dolores
    Barrenetxea, Ziortza
    Berganzo, Javier
    Agirregabiria, Maria
    Ruano-Lopez, Jesus M.
    Marimon, Jose M.
    Olabarria, Garbine
    BIOSENSORS & BIOELECTRONICS, 2012, 32 (01): : 259 - 265