Field studies on indoor thermal environment and start-stop characteristics of the radiant air conditioning system during intermittent heating

被引:2
|
作者
Qu, Minglu [1 ,2 ]
Yan, Xufeng [1 ]
Sang, Xuejing [1 ]
Bai, Yusen [1 ]
Chu, Wenqi [1 ]
Zhu, Xiayu [1 ]
机构
[1] Univ Shanghai Sci & Technol, Sch Environm & Architecture, 516 Jungong Rd, Shanghai, Peoples R China
[2] Xian Univ Architecture & Technol, State Key Lab Green Bldg Western China, 13 Yanta Rd, Xian, Shaanxi, Peoples R China
来源
关键词
Radiant A/C system; Intermittent heating; Operational analysis; Start -stop characteristics; TEMPERATURE; PERFORMANCES; COMFORT; PANELS;
D O I
10.1016/j.jobe.2023.107121
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
With the improvement of social economy, the heating demand of residents in Hot Summer and Cold Winter (HSCW) areas in China is increasing. The radiant air conditioning (A/C) system, is popular as a heating way due to its high comfort, low noise and high energy saving potential. There is still a lack of field research on the system under the intermittent heating mode in the HSCW area. To provide a guide for the operation mode of the radiant A/C system during intermittent heating in HSCW areas, this paper focused on the radiant A/C system with the fresh air system, and then studied system's practical operational parameters and dynamic characteristics in winter. The indoor and outdoor air temperatures and relative humidity, the water temperatures of inlet and outlet of the air source heat pump (ASHP) unit, the supply and return water temperatures of radiant terminals, as well as supply air temperature were analyzed in three stages, i.e., the initial start-up stage, the intermittent shutdown stage and the intermittent start-up stage. The results show that, it took 7 h and 50 min for the indoor air temperature to reach the set indoor temperature during the initial start-up stage. Compared to the initial start-up stage, the intermittent start-up stage reduced the time for the indoor air temperature to reach the set indoor temperature by 4 h and increased the indoor air temperature rise rate by 97%. The indoor air temperature rise rate was 0.46 oC/h and 0.91 oC/h, during the initial start-up and the intermittent startup stage, respectively. The indoor air temperature decrease rate was 0.23 oC/h during the shutdown period. During the entire winter season, the ASHP unit switched on and off intermittently 10 times. The longest shutdown lasted for 111 h, and the indoor air temperature dropped to 17.2oC.
引用
收藏
页数:17
相关论文
共 32 条
  • [21] Effects of indoor environment on EEG and thermal comfort under the ceiling-fan-integrated air conditioning system
    Li, Wenqiang
    Peng, Pei
    Wang, Tao
    Gong, Guangcai
    BUILDING AND ENVIRONMENT, 2024, 257
  • [22] Thermal-environment characteristics and comfort of combined radiant-floor (Korean heating system ondol) and convective cooling system
    LEE Kang-Guk
    HONG Won-Hwa
    Journal of Central South University, 2013, 20 (12) : 3589 - 3603
  • [23] A numerical study on the effects of design/operating parameters of the radiant panel in a radiation-based task air conditioning system on indoor thermal comfort and energy saving for a sleeping environment
    Du, Jing
    Chan, Mingyin
    Pan, Dongmei
    Deng, Shiming
    ENERGY AND BUILDINGS, 2017, 151 : 250 - 262
  • [24] Fuzzy Logic Controlled Simulation in Regulating Thermal Comfort and Indoor Air Quality Using a Vehicle Heating, Ventilation, and Air-Conditioning System
    Subramaniam, Konguvel Rajeswari
    Cheng, Chi-Tsun
    Pang, Toh Yen
    SENSORS, 2023, 23 (03)
  • [25] The indoor thermal environment performance of various air-conditioning system configurations and airflow modes in a large space museum building
    Zhang, Qunli
    Fu, Xinyi
    Liu, Tao
    Zou, Yue
    Jiang, Feng
    INDOOR AND BUILT ENVIRONMENT, 2024,
  • [26] Indoor thermal environment and energy performance in a central air heating system using a heat pump for a house with underfloor space for heat distribution
    Kindaichi, Sayaka
    Kindaichi, Tomonori
    BUILDING SERVICES ENGINEERING RESEARCH & TECHNOLOGY, 2022, 43 (06): : 755 - 766
  • [27] Study on indoor thermal environment in integrated facade system: Sun shading effect of louver and case study of annual air-conditioning load
    Sato, Tomoyuki
    Kubo, Kentaro
    Hikone, Shigeru
    Misawa, Yutaka
    Cho, Wanghee
    Iwamoto, Shizuo
    Iwata, Mamoru
    Journal of Environmental Engineering, 2012, 77 (676) : 467 - 474
  • [28] An optimal control method for small-scale GSHP-integrated air-conditioning system to improve indoor thermal environment control
    Gao, Jiajia
    Yan, Junjun
    Xu, Xinhua
    Yan, Tian
    Huang, Gongsheng
    JOURNAL OF BUILDING ENGINEERING, 2022, 59
  • [29] A novel air source heat pump powered bed-based space heating (ASHP-BBSH) system for improved indoor thermal environment
    Fang, Guanyu
    Chen, Wenjing
    Wang, Caixia
    Chan, Ming-yin
    Deng, Shiming
    Liu, Xuefeng
    Yan, Huaxia
    INNOVATIVE SOLUTIONS FOR ENERGY TRANSITIONS, 2019, 158 : 2231 - 2236
  • [30] Investigation of dynamic start-up and thermal airflow characteristics for air-carrying energy heating and cooling system: Sidewall, ceiling, and composite walls
    Huang, Yuting
    Gong, Guangcai
    Liu, Jiaqing
    Wang, Yuxin
    Shi, Xing
    Qin, Bin
    BUILDING AND ENVIRONMENT, 2024, 264