Optimal Tuned Inerter Dampers for Vibration Control Performance of Adjacent Building Structures

被引:8
|
作者
Kang, Xiaofang [1 ,2 ]
Tang, Jianjun [1 ]
Li, Feng [1 ]
Wu, Jian [1 ]
Wei, Jiachen [1 ]
Huang, Qiwen [1 ]
Li, Zhi [1 ]
Zhang, Fuyi [1 ]
Sheng, Ziyi [1 ]
机构
[1] Anhui Jianzhu Univ, Sch Civil Engn, Hefei 230601, Peoples R China
[2] Anhui Jianzhu Univ, Key Lab Intelligent Underground Detect Technol, Hefei 230601, Peoples R China
关键词
adjacent building; vibration control; TID; H-2 norm theory; Monte Carlo pattern search method; MASS DAMPERS; VISCOUS DAMPERS; DESIGN; TMD; OPTIMIZATION; PROTECTION;
D O I
10.3390/buildings13071803
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Under the effect of strong earthquakes, collisions or excessive inter-story displacements may occur between adjacent building structures to the extent that the building structure is damaged. The traditional seismic measures for these structures can no longer meet the needs in practical engineering. In this paper, we propose the application of parallel and serial TID-based control systems in adjacent buildings as an example of a single-story adjacent building, and use it to form a new adjacent building seismic reduction structure. In this paper, the dynamic characteristics and design parameter optimization of the vibration control system are investigated by means of the Monte Carlo pattern search method and H-2 norm theory. The results show that the introduction of serial and parallel TID in adjacent building structures can effectively improve the seismic resistance of adjacent buildings. The problem of vibration amplification caused by resonance is obviously improved, which is especially evident in the adjacent building structure vibration control system based on parallel TID. The vibration control system of adjacent building structures based on parallel TID is more robust. When optimizing the right building, the damping requirement of the TID decreases for the vibration control system based on parallel TID as the adjacent building mass ratio increases, while the damping requirement of the TID increases for the vibration control system based on serial TID. In both vibration control systems, the difference in the optimal inertial mass ratio is small. In practice, a moderate increase in the difference between adjacent building masses can have a positive effect on the vibration control performance of the systems. The main contribution of this paper is to fill the research gap in parallel and serial TID applications for adjacent building vibration reduction.
引用
收藏
页数:23
相关论文
共 50 条
  • [41] Seismic response control of adjacent buildings using optimal backward-shared tuned mass damper inerter and optimal backward-shared tuned inerter damper
    Djerouni S.
    Abdeddaim M.
    Ounis A.
    Asian Journal of Civil Engineering, 2021, 22 (8) : 1499 - 1523
  • [42] Optimal design and performance analysis of a tuned negative-stiffness inerter mass damper for vibration control systems
    Tai, Yu-ji
    Cheng, Lu-lu
    Liu, Liang-kun
    Bao, Hai-ying
    Wang, Shi-long
    STRUCTURES, 2025, 73
  • [43] CONTROL OF WIND-INDUCED TALL BUILDING VIBRATION BY TUNED MASS DAMPERS
    XU, YL
    KWOK, KCS
    SAMALI, B
    JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 1992, 40 (01) : 1 - 32
  • [45] Vibration reduction of semisubmersible floating wind turbine using optimized tuned mass and tuned inerter dampers
    Lambert, Duncan L.
    Zuo, Lei
    IFAC PAPERSONLINE, 2023, 56 (03): : 229 - 234
  • [46] Tuned inerter dampers for civil structures subjected to earthquake ground motions: optimum design and seismic performance
    Shen, Wenai
    Niyitangamahoro, Abdou
    Feng, Zhouquan
    Zhu, Hongping
    ENGINEERING STRUCTURES, 2019, 198
  • [47] A review on the use of the inerter device in the structural coupling technique for adjacent building vibration control
    Pippi, Augusto de Souza
    Avila, Suzana M.
    Doz, Graciela
    STRUCTURES, 2022, 42 : 480 - 501
  • [48] Effective damping ratio enhancement effect of tuned inerter dampers for seismic response control of civil structures
    He, Hui
    You, Chunhua
    Tan, Ping
    Xiang, Yue
    Yang, Kui
    ENGINEERING STRUCTURES, 2023, 279
  • [49] Performance of tuned liquid column dampers considering maximum liquid motion in seismic vibration control of structures
    Chakraborty, Subrata
    Debbarma, Rama
    Marano, Giuseppe Carlo
    JOURNAL OF SOUND AND VIBRATION, 2012, 331 (07) : 1519 - 1531
  • [50] Optimal control of vibration by multiple tuned liquid dampers using Taguchi method
    Nguyen Van Khang
    Do The Duong
    Nguyen Thi Van Huong
    Nguyen Duc Thi Thu Dinh
    Vu Duc Phuc
    Journal of Mechanical Science and Technology, 2019, 33 : 1563 - 1572