摘要
Under the effect of strong earthquakes, collisions or excessive inter-story displacements may occur between adjacent building structures to the extent that the building structure is damaged. The traditional seismic measures for these structures can no longer meet the needs in practical engineering. In this paper, we propose the application of parallel and serial TID-based control systems in adjacent buildings as an example of a single-story adjacent building, and use it to form a new adjacent building seismic reduction structure. In this paper, the dynamic characteristics and design parameter optimization of the vibration control system are investigated by means of the Monte Carlo pattern search method and H-2 norm theory. The results show that the introduction of serial and parallel TID in adjacent building structures can effectively improve the seismic resistance of adjacent buildings. The problem of vibration amplification caused by resonance is obviously improved, which is especially evident in the adjacent building structure vibration control system based on parallel TID. The vibration control system of adjacent building structures based on parallel TID is more robust. When optimizing the right building, the damping requirement of the TID decreases for the vibration control system based on parallel TID as the adjacent building mass ratio increases, while the damping requirement of the TID increases for the vibration control system based on serial TID. In both vibration control systems, the difference in the optimal inertial mass ratio is small. In practice, a moderate increase in the difference between adjacent building masses can have a positive effect on the vibration control performance of the systems. The main contribution of this paper is to fill the research gap in parallel and serial TID applications for adjacent building vibration reduction.
引用
收藏
页数:23
相关论文
共 50 条
  • [21] OPTIMAL DESIGN OF TUNED MASS DAMPERS WITH VARIABLE INERTER AND DAMPING
    Chang, Chang-Ching
    Wang, Jer-Fu
    Lin, Chi-Chang
    Lin, Tzu-Ting
    Lin, Chih-Shiuan
    PROCEEDINGS OF THE ASME PRESSURE VESSELS AND PIPING CONFERENCE, 2019, VOL 8, 2019,
  • [22] Optimum tuning parameters of tuned mass dampers for vibration control of irregular highrise building structures
    Gutierrez Soto, Mariantonieta
    Adeli, Hojjat
    JOURNAL OF CIVIL ENGINEERING AND MANAGEMENT, 2014, 20 (05) : 609 - 620
  • [23] VIBRATION CONTROL OF METAL SPATIAL STRUCTURES WITH TUNED MASS DAMPERS
    Yoshinaka, Susumu
    Kawaguchi, Ken'ichi
    Fujiwara, Jun
    Kishida, Akiko
    Yamakawa, Makoto
    JOURNAL OF THE INTERNATIONAL ASSOCIATION FOR SHELL AND SPATIAL STRUCTURES, 2023, 64 (02): : 95 - 108
  • [24] Design and Evaluation of Tuned Inerter-Based Dampers for the Seismic Control of MDOF Structures
    Wen, Yongkui
    Chen, Zhengqing
    Hua, Xugang
    JOURNAL OF STRUCTURAL ENGINEERING, 2017, 143 (04)
  • [25] Vertical vibration control of structures with tuned liquid column dampers
    Ding, Hao
    Bi, Kaiming
    Song, Jian
    Fang, Xiaojun
    INTERNATIONAL JOURNAL OF MECHANICAL SCIENCES, 2024, 279
  • [26] Parameter optimization of vibration control system for adjacent building structures based on negative stiffness inerter damper
    Kang, Xiaofang
    Tang, Jianjun
    Wei, Jiachen
    Jiang, Xueqin
    Sheng, Ziyi
    Shi, Xianzeng
    SCIENTIFIC REPORTS, 2024, 14 (01)
  • [27] Optimal Design of Multiple Tuned Liquid Column Dampers for Seismic Vibration Control of MDOF Structures
    Mohebbi, Mohtasham
    Dabbagh, Hamed Rasouli
    Shakeri, Kazem
    PERIODICA POLYTECHNICA-CIVIL ENGINEERING, 2015, 59 (04): : 543 - 558
  • [28] Magnetically tuned mass dampers for optimal vibration damping of large structures
    Bourquin, Frederic
    Caruso, Giovanni
    Peigney, Michael
    Siegert, Dominique
    SMART MATERIALS AND STRUCTURES, 2014, 23 (08)
  • [29] Optimal design and performance evaluation of a novel hysteretic friction tuned inerter damper for vibration control systems
    Hua, Xu-gang
    Tai, Yu-ji
    Huang, Zhi-wen
    Chen, Zheng-qing
    STRUCTURAL CONTROL & HEALTH MONITORING, 2021, 28 (08):
  • [30] Mass dampers and their optimal designs for building vibration control
    Chang, CC
    ENGINEERING STRUCTURES, 1999, 21 (05) : 454 - 463