Characterization of baseline hemodynamics after the Fontan procedure: a retrospective cohort study on the comparison of 4D Flow MRI and computational fluid dynamics

被引:0
|
作者
Lee, Gyu-Han [1 ]
Koo, Hyun Jung [2 ]
Park, Kyung Jin [2 ,3 ]
Yang, Dong Hyun [2 ]
Ha, Hojin [4 ]
机构
[1] Kangwon Natl Univ, Dept Interdisciplinary Program Biohlth Machinery C, Chunchon, South Korea
[2] Univ Ulsan, Res Inst Radiol, Asan Med Ctr, Dept Radiol,Coll Med, Seoul, South Korea
[3] Yonsei Univ, Dept Elect & Elect Engn, Seoul, South Korea
[4] Kangwon Natl Univ, Dept Smart Hlth Sci & Technol, Chunchon, South Korea
基金
新加坡国家研究基金会;
关键词
Fontan circulation; 4D Flow MRI; computational fluid dynamics; blood flow distribution; hemodynamics; CARDIAC MAGNETIC-RESONANCE; BLOOD-FLOW; ENERGY-LOSS; KINETIC-ENERGY; RESOLUTION;
D O I
10.3389/fphys.2023.1199771
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
Introduction: The aim of this study was to characterize the hemodynamics of Fontan patients using both four-dimensional flow magnetic resonance imaging (4D Flow MRI) and computational fluid dynamics (CFD). Methods: Twenty-nine patients (3.5 +/- 0.5 years) who had undergone the Fontan procedure were enrolled, and the superior vena cava (SVC), left pulmonary artery (LPA), right pulmonary artery (RPA), and conduitwere segmented based on 4D Flow MRI images. Velocity fields from4D Flow MRI were used as boundary conditions for CFD simulations. Hemodynamic parameters such as peak velocity (Vmax), pulmonary flow distribution (PFD), kinetic energy (KE), and viscous dissipation (VD) were estimated and compared between the two modalities. Results and discussion: The Vmax, KE, VD, PFDTotal to LPA, and PFDTotal to RPA of the Fontan circulation were 0.61 +/- 0.18 m/s, 0.15 +/- 0.04 mJ, 0.14 +/- 0.04 mW, 41.3 +/- 15.7%, and 58.7 +/- 15.7% from 4D Flow MRI; and 0.42 +/- 0.20 m/s, 0.12 +/- 0.05 mJ, 0.59 +/- 0.30 mW, 40.2 +/- 16.4%, and 59.8 +/- 16.4% from CFD, respectively. The overall velocity field, KE, and PFD from the SVC were in agreement between modalities. However, PFD from the conduit and VD showed a large discrepancy between 4D Flow MRI and CFD, most likely due to spatial resolution and data noise. This study highlights the necessity for careful consideration when analyzing hemodynamic data from different modalities in Fontan patients.
引用
收藏
页数:14
相关论文
共 50 条
  • [1] Hemodynamic Evaluation of Intracranial Aneurysm: Comparison of Computational Fluid Dynamics with 4D Flow MRI
    Misaki, Kouichi
    Futami, Kazuya
    Uno, Takehiro
    Nambu, Iku
    Yoshikawa, Akifumi
    Kamide, Tomoya
    Nakada, Mitsutoshi
    NEUROSURGERY, 2020, 67 : 120 - 121
  • [2] Inflow Hemodynamics of Intracranial Aneurysms: A Comparison of Computational Fluid Dynamics and 4D Flow Magnetic Resonance Imaging
    Misaki, Kouichi
    Futami, Kazuya
    Uno, Takehiro
    Nambu, Iku
    Yoshikawa, Akifumi
    Kamide, Tomoya
    Nakada, Mitsutoshi
    JOURNAL OF STROKE & CEREBROVASCULAR DISEASES, 2021, 30 (05):
  • [3] Thoracic aortic aneurysm: 4D flow MRI and computational fluid dynamics model
    Callaghan, F. M.
    Karkouri, J.
    Broadhouse, K.
    Evin, M.
    Fletcher, D. F.
    Grieve, S. M.
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2015, 18 : 1894 - 1895
  • [4] The effect of resolution on viscous dissipation measured with 4D flow MRI in patients with Fontan circulation: Evaluation using computational fluid dynamics
    Cibis, Merih
    Jarvis, Kelly
    Markl, Michael
    Rose, Michael
    Rigsby, Cynthia
    Barker, Alex J.
    Wentzel, Jolanda J.
    JOURNAL OF BIOMECHANICS, 2015, 48 (12) : 2984 - 2989
  • [5] New imaging tools in cardiovascular medicine: computational fluid dynamics and 4D flow MRI
    Itatani, Keiichi
    Miyazaki, Shohei
    Furusawa, Tokoki
    Numata, Satoshi
    Yamazaki, Sachiko
    Morimoto, Kazuki
    Makino, Rina
    Morichi, Hiroko
    Nishino, Teruyasu
    Yaku, Hitoshi
    GENERAL THORACIC AND CARDIOVASCULAR SURGERY, 2017, 65 (11) : 611 - 621
  • [6] New imaging tools in cardiovascular medicine: computational fluid dynamics and 4D flow MRI
    Keiichi Itatani
    Shohei Miyazaki
    Tokoki Furusawa
    Satoshi Numata
    Sachiko Yamazaki
    Kazuki Morimoto
    Rina Makino
    Hiroko Morichi
    Teruyasu Nishino
    Hitoshi Yaku
    General Thoracic and Cardiovascular Surgery, 2017, 65 : 611 - 621
  • [7] Establishing the distribution of cerebrovascular resistance using computational fluid dynamics and 4D flow MRI
    Vikstrom, Axel
    Holmlund, Petter
    Holmgren, Madelene
    Wahlin, Anders
    Zarrinkoob, Laleh
    Malm, Jan
    Eklund, Anders
    SCIENTIFIC REPORTS, 2024, 14 (01):
  • [8] Accelerated sequences of 4D flow MRI using GRAPPA and compressed sensing: A comparison against conventional MRI and computational fluid dynamics
    Garreau, Morgane
    Puiseux, Thomas
    Toupin, Solenn
    Giese, Daniel
    Mendez, Simon
    Nicoud, Franck
    Moreno, Ramiro
    MAGNETIC RESONANCE IN MEDICINE, 2022, 88 (06) : 2432 - 2446
  • [9] ESTIMATION OF WALL SHEAR STRESS USING 4D FLOW CARDIOVASCULAR MRI AND COMPUTATIONAL FLUID DYNAMICS
    Soudah, E.
    Casacuberta, J.
    Gamez-Montero, P. J.
    Perez, J. S.
    Rodriguez-Cancio, M.
    Raush, G.
    Li, C. H.
    Carreras, F.
    Castilla, R.
    JOURNAL OF MECHANICS IN MEDICINE AND BIOLOGY, 2017, 17 (03)
  • [10] Comparison of 4D Phase-Contrast MRI Flow Measurements to Computational Fluid Dynamics Simulations of Cerebrospinal Fluid Motion in the Cervical Spine
    Yiallourou, Theresia I.
    Kroeger, Jan Robert
    Stergiopulos, Nikolaos
    Maintz, David
    Martin, Bryn A.
    Bunck, Alexander C.
    PLOS ONE, 2012, 7 (12):