Thermo-hydraulic performance investigation of double pass solar air heater integrated with PCM-based thermal energy storage

被引:7
|
作者
Hedau, Ankush [1 ]
Singal, S. K. [1 ]
机构
[1] Indian Inst Technol Roorkee, Dept Hydro & Renewable Energy, Roorkee 247667, India
关键词
Solar energy; Heat transfer; Phase change material; Thermal energy storage; Friction factor; Thermo-hydraulic performance; TRANSFER ENHANCEMENT; ROUGHNESS; IMPROVEMENT; CHANNEL; DUCT;
D O I
10.1016/j.est.2023.110202
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The solar air heater (SAH) is one of the ways to utilize solar energy for the purpose of drying, greenhouse heating and air conditioning. However, the SAHs are unable to deliver reliable thermo-hydraulic performance as a result of the intermittent nature of solar energy and the low convective heat transfer coefficient. Thus, in the present study, a three-dimensional numerical investigation is performed to study the thermo-hydraulic performance of the double pass solar air heater (DPSAH) having semi-cylindrical PCM tubes and perforated baffles as roughness geometry. The parameters selected for this study include baffle height ratio (eb/H) from 0.4 and 0.8, tube radius ratio (rt/H) from 0.2 and 0.5, and Reynolds numbers (Re) from 3000 and 13,000. Experimental validation has been conducted to verify the numerical results, and it has been found to be well-validated with mean absolute errors of 6.5 % and 1.2 % for the Nusselt number (Nur) and friction factor (fr), respectively. The maximum Nusselt number (Nur) is found to be 200.08 at Re of 13,000, while the maximum friction factor (fr) is measured to be 0.6290 at Re of 3000, which corresponds to eb/H of 0.8 and rt/H of 0.3. The maximum heat transfer enhancement (Nur/Nus) in comparison to the smooth duct is found to be 5.08 times with a maximum friction factor increment (fr/fs) of 65.80 times, which corresponds to eb/H of 0.8, Re of 13,000 and rt/H of 0.3. The maximum thermo-hydraulic performance parameter (THPP) is observed to be 1.83 at Re of 13,000, rt/H of 0.2 and eb/H of 0.4. This study contributes to the design and optimisation of SAHs by incorporating thermal energy storage and roughness geometries.
引用
收藏
页数:22
相关论文
共 50 条
  • [41] Experimental determination of the effect of change in relative roughness pitch on the thermo-hydraulic performance of air heater working with solar energy
    Bansal, Gagan
    Kishore, Chandra
    Selvaraj, R. Meby
    Dwivedi, Vijay Kumar
    MATERIALS TODAY-PROCEEDINGS, 2021, 46 : 10668 - 10671
  • [42] Effects of Nanofluids on the Performance of a PCM-Based Thermal Energy Storage System
    Addad, Y.
    Abutayeh, M.
    Abu-Nada, E.
    JOURNAL OF ENERGY ENGINEERING, 2017, 143 (04)
  • [43] Thermal Performance of a PCM-Based Thermal Energy Storage with Metal Foam Enhancement
    Chen, Xue
    Li, Xiaolei
    Xia, Xinlin
    Sun, Chuang
    Liu, Rongqiang
    ENERGIES, 2019, 12 (17)
  • [44] Encapsulated PCM based double pass solar air heater: A comparative experimental study
    Sudhakar, P.
    Cheralathan, M.
    CHEMICAL ENGINEERING COMMUNICATIONS, 2021, 208 (06) : 788 - 800
  • [45] Numerical Analysis of an Aerofoil Fin Integrated Double Pass Solar Air Heater for Thermal Performance Enhancement
    Nagaraj, Madhwesh
    Reddy, Manu Krishna
    Sheshadri, Arun Kumar Honnesara
    Karanth, Kota Vasudeva
    SUSTAINABILITY, 2023, 15 (01)
  • [46] Thermal investigation of PCM-based high temperature thermal energy storage in packed bed
    Peng, Hao
    Dong, Huihua
    Ling, Xiang
    ENERGY CONVERSION AND MANAGEMENT, 2014, 81 : 420 - 427
  • [47] Thermo-hydraulic performance investigation of solar air heater duct having staggered D-shaped ribs: Numerical approach
    Dutt, Nitesh
    Hedau, Ankush
    Kumar, Ashwani
    Awasthi, Mukesh Kumar
    Hedau, Sachin
    Meena, Chandan Swaroop
    HEAT TRANSFER, 2024, 53 (03) : 1501 - 1531
  • [48] A comparative analysis of thermo-hydraulic performance of a roughened solar air heater using various rib shapes
    Gawande, Vipin B.
    Dhoble, A. S.
    Zodpe, D. B.
    Mangrulkar, Chidanand
    AUSTRALIAN JOURNAL OF MECHANICAL ENGINEERING, 2020, 18 (03) : 331 - 350
  • [49] Thermo-hydraulic performance of a solar air heater with staggered C-shape finned absorber plate
    Saravanan, A.
    Murugan, M.
    Reddy, M. Sreenivasa
    Ranjit, P. S.
    Elumalai, P., V
    Kumar, Pramod
    Sree, S. Rama
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2021, 168
  • [50] A review of CFD methodology used in literature for predicting thermo-hydraulic performance of a roughened solar air heater
    Gawande, Vipin B.
    Dhoble, A. S.
    Zodpe, D. B.
    Chamoli, Sunil
    RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2016, 54 : 550 - 605