Thermo-hydraulic performance investigation of double pass solar air heater integrated with PCM-based thermal energy storage

被引:7
|
作者
Hedau, Ankush [1 ]
Singal, S. K. [1 ]
机构
[1] Indian Inst Technol Roorkee, Dept Hydro & Renewable Energy, Roorkee 247667, India
关键词
Solar energy; Heat transfer; Phase change material; Thermal energy storage; Friction factor; Thermo-hydraulic performance; TRANSFER ENHANCEMENT; ROUGHNESS; IMPROVEMENT; CHANNEL; DUCT;
D O I
10.1016/j.est.2023.110202
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The solar air heater (SAH) is one of the ways to utilize solar energy for the purpose of drying, greenhouse heating and air conditioning. However, the SAHs are unable to deliver reliable thermo-hydraulic performance as a result of the intermittent nature of solar energy and the low convective heat transfer coefficient. Thus, in the present study, a three-dimensional numerical investigation is performed to study the thermo-hydraulic performance of the double pass solar air heater (DPSAH) having semi-cylindrical PCM tubes and perforated baffles as roughness geometry. The parameters selected for this study include baffle height ratio (eb/H) from 0.4 and 0.8, tube radius ratio (rt/H) from 0.2 and 0.5, and Reynolds numbers (Re) from 3000 and 13,000. Experimental validation has been conducted to verify the numerical results, and it has been found to be well-validated with mean absolute errors of 6.5 % and 1.2 % for the Nusselt number (Nur) and friction factor (fr), respectively. The maximum Nusselt number (Nur) is found to be 200.08 at Re of 13,000, while the maximum friction factor (fr) is measured to be 0.6290 at Re of 3000, which corresponds to eb/H of 0.8 and rt/H of 0.3. The maximum heat transfer enhancement (Nur/Nus) in comparison to the smooth duct is found to be 5.08 times with a maximum friction factor increment (fr/fs) of 65.80 times, which corresponds to eb/H of 0.8, Re of 13,000 and rt/H of 0.3. The maximum thermo-hydraulic performance parameter (THPP) is observed to be 1.83 at Re of 13,000, rt/H of 0.2 and eb/H of 0.4. This study contributes to the design and optimisation of SAHs by incorporating thermal energy storage and roughness geometries.
引用
收藏
页数:22
相关论文
共 50 条
  • [21] Thermo-hydraulic performance of solar air heater having winglet type roughness element
    Kumar, Amit
    Layek, Apurba
    JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2022, 147 (19) : 10481 - 10495
  • [22] Thermo-Hydraulic Performance Characteristics and Optimization of Protrusion Rib Roughness in Solar Air Heater
    Alam, Tabish
    Meena, Chandan Swaroop
    Balam, Nagesh Babu
    Kumar, Ashok
    Cozzolino, Raffaello
    ENERGIES, 2021, 14 (11)
  • [23] Thermal performance investigation of double pass-finned plate solar air heater
    El-Sebaii, A. A.
    Aboul-Enein, S.
    Ramadan, M. R. I.
    Shalaby, S. M.
    Moharram, B. M.
    APPLIED ENERGY, 2011, 88 (05) : 1727 - 1739
  • [24] Investigation of thermo-hydraulic performance of concentrated solar air-heater with internal multiple-fin array
    Kasperski, Jacek
    Nems, Magdalena
    APPLIED THERMAL ENGINEERING, 2013, 58 (1-2) : 411 - 419
  • [25] Thermal performance of a packed bed double pass solar air heater with a latent heat storage system: an experimental investigation
    Dosapati, Chaitanya
    Mandapati, Mohan Jagadeesh Kumar
    WORLD JOURNAL OF ENGINEERING, 2019, 17 (02) : 203 - 213
  • [26] Thermo-hydraulic performance analysis of a solar air heater roughened with reverse NACA profile ribs
    Patel, Yogesh M.
    Jain, Sanjay, V
    Lakhera, Vikas J.
    APPLIED THERMAL ENGINEERING, 2020, 170
  • [27] ANN model for prediction of thermo-hydraulic performance of a solar air heater with vertical cylindrical ribs
    Singh, Sarvapriya
    Suman, Siddharth
    Mitra, Santanu
    Kumar, Manish
    ENERGY REPORTS, 2022, 8 : 585 - 592
  • [28] Thermal Performance of Double Pass Solar Air Heater With Tubular Solar Absorber
    Hussein, Nassr Fadhil
    Ahmed, Sabah T.
    Ekaid, Ali L.
    INTERNATIONAL JOURNAL OF RENEWABLE ENERGY DEVELOPMENT-IJRED, 2023, 12 (01): : 11 - 21
  • [29] Investigations on thermo-hydraulic performance of broken arc rib in a rectangular duct of solar air heater
    Gill, R. S.
    Hans, V. S.
    Singh, Sukhmeet
    INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2017, 88 : 20 - 27
  • [30] Experimental study on thermo-hydraulic performance of a solar air heater with rectangular perforated duct inserts
    Arunkumar, H. S.
    Kumar, Shiva
    Karanth, K. Vasudeva
    SOLAR ENERGY, 2021, 227 : 179 - 189