Detection of Signal of Fire Source for Coal Spontaneous Combustion Applied with Acoustic Wave

被引:6
|
作者
Ren, Shuaijing [1 ,2 ]
Zhang, Yanni [1 ,3 ]
Xiao, Yang [1 ,3 ]
Deng, Jun [1 ,3 ]
Ma, Teng [1 ,2 ]
Zhang, Yutao [1 ,3 ]
机构
[1] Xian Univ Sci & Technol, Sch Safety Sci & Engn, 58 Yanta Mid Rd, Xian 710054, Shaanxi, Peoples R China
[2] Xian Univ Sci & Technol, Sch Energy Engn, 58 Yanta Mid Rd, Xian 710054, Shaanxi, Peoples R China
[3] Xian Univ Sci & Technol, Shaanxi Key Lab Prevent & Control Coal Fire, 58 Yanta Mid Rd, Xian 710054, Shaanxi, Peoples R China
基金
中国国家自然科学基金;
关键词
Coal spontaneous combustion; Fire source detection; Acoustic wave; Sound source signal; Cross-correlation; TEMPERATURE DISTRIBUTION; GASES; FLOW; RECONSTRUCTION; MINE;
D O I
10.1007/s11053-023-10225-0
中图分类号
P [天文学、地球科学];
学科分类号
07 ;
摘要
Coal spontaneous combustion can cause a series of problems in terms of wasted resources, casualties, and environmental pollution. Accurate detection of the fire source in loose coal is the key to preventing coal spontaneous combustion. Acoustic temperature measurement has significant advantages of strong stability, high accuracy, and wide measurement range, which can make up for the shortcomings of traditional fire source detection methods. Detecting the optimum source signal for loose coal temperature measurement is the basis and prerequisite for the realization of acoustic temperature measurement. Therefore, the anti-interference characteristics of three typical sound source signals were tested and analyzed through a self-designed sound wave propagation characteristic test system. The cross-correlations among maximum length sequence signal, pulse signal, and linear sweep signal were compared and analyzed. Compared to the other two signals, the main peak of the cross-correlation coefficient of the linear sweep signal was more prominent and its pseudo-peaks interfered less with its main peak. This signal had strong anti-interference ability, and it can be used as a basic acoustic source signal for temperature measurement of loose coal. To further screen out the optimal frequency band and length of the linear sweep signal, four bituminous coals were selected as the propagation medium. The main peak value and the difference between the main peak and the maximum pseudo-peak of the cross-correlation coefficient were proposed as the evaluation indicators. The optimum signal frequency bands of long-flame coal, non-caking coal, coking coal, and lean coal were 400-900, 400-900, 500-1200, and 400-900 Hz, and the optimum signal length of four coals was 0.1 s. The study results can provide theoretical support for the selection of acoustic temperature measurement signals for loose coal.
引用
收藏
页码:2243 / 2256
页数:14
相关论文
共 50 条
  • [22] Automatic signal detection applied to fire control by infrared digital signal processing
    Vergara, L
    Bernabeu, P
    SIGNAL PROCESSING, 2000, 80 (04) : 659 - 669
  • [23] A new high efficiency organic inhibitor applied to prevent coal spontaneous combustion
    Cheng, Genyin
    Chen, Fei
    Jiang, Yaqin
    Gao, Ming
    PROCEEDINGS OF THE 2016 6TH INTERNATIONAL CONFERENCE ON MACHINERY, MATERIALS, ENVIRONMENT, BIOTECHNOLOGY AND COMPUTER (MMEBC), 2016, 88 : 1931 - 1935
  • [24] The technique of fire extinguishing with gel for coal spontaneous combustion in fully mechanized caving face
    Wen, H
    Xu, JC
    Deng, J
    Zhang, XH
    PROCEEDINGS IN MINING SCIENCE AND SAFETY TECHNOLOGY, 2002, : 448 - 452
  • [25] Rules of variation in hydrogen during reignition of underground fire zones of spontaneous coal combustion
    ZHOU Fubao LI Jinhai LIU Yusheng SHAO He School of Safety Engineering China University of Mining Technology Xuzhou China State Key Laboratory of Coal Resources and Safe Mining China University of Mining Technology Xuzhou China
    MiningScienceandTechnology, 2010, 20 (04) : 499 - 503
  • [27] Laboratory Investigation to Assess Spontaneous Combustion/Fire During Extraction of Thick Coal Seam
    Mohalik N.K.
    Mishra D.
    Ray S.K.
    Varma N.K.
    Khan A.M.
    Sahay N.
    Journal of The Institution of Engineers (India): Series D, 2019, 100 (02): : 229 - 242
  • [28] Rules of variation in hydrogen during reignition of underground fire zones of spontaneous coal combustion
    Zhou F.
    Li J.
    Liu Y.
    Shao H.
    Mining Science and Technology, 2010, 20 (04): : 499 - 503
  • [29] An intelligent gel designed to control the spontaneous combustion of coal: Fire prevention and extinguishing properties
    Cheng, Weimin
    Hu, Xiangming
    Xie, Jun
    Zhao, Yanyun
    FUEL, 2017, 210 : 826 - 835
  • [30] The technique of fire extinguishing with gel for coal spontaneous combustion in fully mechanized caving face
    Wen, Hu
    Xu, Jingcai
    Deng, Jun
    Zhang, Xinhai
    Proceedings in Mining Science and Safety Technology, 2002, : 448 - 452